Juergen Kratzsch

Prof. Dr. Juergen Kratzsch

University of Leipzig
+1

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Journal of Chromatography A
Verified
Journal Article
Closed access
AGAlexander Gaudl
Alexander Gaudl
JKJuergen Kratzsch
Juergen Kratzsch
YBYoon Ju Bae
Yoon Ju Bae
Wieland KiessWieland Kiess
Wieland Kiess
JTJoachim Thiery
Joachim Thiery
Uta CeglarekUta Ceglarek
Uta Ceglarek


1 March 2011 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
JKJuergen Kratzsch
Juergen Kratzsch
APAnne Petzold
Anne Petzold
FRFriedhelm Raue
Friedhelm Raue
WRWalter Reinhardt
Walter Reinhardt
MBMartina Bröcker-Preuβ
Martina Bröcker-Preuβ
DFDagmar Führer-Sakel
Dagmar Führer-Sakel
BACKGROUND: Calcitonin (CT) is a sensitive marker for evaluation of medullary thyroid cancer (MTC). However, CT measurement can vary with assay- and nonassay-dependent factors, and procalcitonin (PCT) measurement has been proposed for evaluating questionable increases in CT. METHODS: We tested 2 fully automated CT assays (Immulite [IL] and Liaison [LIA]) and 1 nonautomated CT assay (IRMA, Medipan) and compared these results with PCT (Brahms Kryptor). We evaluated preanalytical conditions and PCT cross-reactivity in sera of 437 patients with clinical conditions associated with hypercalcitoninemia. Additionally, we determined the true “nil” CT concentration in 60 thyroidectomized patients and defined CT cutoff concentrations for pentagastrin stimulation testing in 13 chronic kidney disease (CKD) patients and 10 MTC patients. RESULTS: Markedly decreased CT concentrations were found after storage of sera for >2 h at room temperature and >6 h at 4 °C. Cutoff concentrations for basal and stimulated CT were disease and assay dependent. Proton pump inhibitor therapy was the most frequent reason for increased CT. PCT concentrations were higher in patients with MTC than in patients with CKD without infections (P < 0.001). Whereas IL and LIA demonstrated comparable analytical quality, the IRMA gave increased CT concentrations in nil sera and showed cross-reactivity with PCT in patients with concomitant bacterial infection. CONCLUSIONS: IL, LIA, and IRMA detected increased CT concentrations in non-MTC patients and discriminated MTC from CKD patients in pentagastrin tests. PCT assessment may be helpful in the diagnostic work-up of increased CT concentrations in questionable clinical circumstances.

1 September 2014 in European Journal of Endocrinology
Verified
Journal Article
Closed access
PDF file
IWI V Wagner
I V Wagner
CPC Paetzold
C Paetzold
RGR Gausche
R Gausche
MVMandy Vogel
Mandy Vogel
AKA Koerner
A Koerner
JKJuergen Kratzsch
Juergen Kratzsch
Context: Cutoff limits of GH stimulation tests to diagnose GH deficiency (GHD) in children and adolescents are not sufficiently validated by clinical studies due to discrepancies in the performance of GH immunoassays and lack of available study populations.Objective: We aimed to establish new cutoff limits for GH stimulation tests based on clinical evidence and compared these immunoassay-based values with an antibody-independent mass spectrometric method.Design and setting: In a retrospective study, GH cutoff limits for eight different immunoassays and isotope dilution mass spectrometry (ID-MS) were calculated from hGH peak concentrations of short-statured children with and without GHD.Patients: We compared the serum GH peak concentrations at GH stimulation test of 52 short-statured children and adolescents, who have normal GH secretion at initial workup and normal growth in the follow-up, with the serum GH peak concentrations of 44 GHD patients in the same age range, in order to optimize the cutoff limit calculation.Results: Discriminant analysis of re-measured GH led to a new cutoff limit of 7.09 μg/l using the iSYS assay (IDS) and the limits for the other seven hGH assays varied between 4.32 and 7.77 μg/l. For ID-MS, cutoffs of 5.48 μg/l (22k GH) and 7.43 μg/l (total GH) were ascertained.Conclusion: The establishment of method-specific clinical evidence-based GH cutoff limits is of importance to ensure adequate clinical diagnosis and treatment of children and adolescents with GHD. ID-MS may become an important tool for providing both reliable and sustainable SI traceability of GH measurements in the future.

1 March 2019 in Psychoneuroendocrinology
Verified
Journal Article
Closed access
YBYoon Ju Bae
Yoon Ju Bae
JRJanis Reinelt
Janis Reinelt
JNJeffrey Netto
Jeffrey Netto
MUMarie Uhlig
Marie Uhlig
AWAnja Willenberg
Anja Willenberg
JKJuergen Kratzsch
Juergen Kratzsch

1 July 2016 in Clinical Biochemistry
Verified
Journal Article
Closed access
ADAnne Dathan-Stumpf
Anne Dathan-Stumpf
MVMandy Vogel
Mandy Vogel
AHAndreas Hiemisch
Andreas Hiemisch
JTJoachim Thiery
Joachim Thiery
RBRalph Burkhardt
Ralph Burkhardt
Wieland KiessWieland Kiess
Wieland Kiess