Sebastian Seget

Dr. Sebastian Seget

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

31 October 2022 in Diabetes Technology & Therapeutics
Verified
Journal Article
Open access
SSSebastian Seget
Sebastian Seget
EREwa Rusak
Ewa Rusak
JPJoanna Polanska
Joanna Polanska
PJPrzemysława Jarosz-Chobot
Przemysława Jarosz-Chobot
Background: The aim of this prospective open-label single-arm single-center follow-up study was to analyze glycemic control in children and adolescents with type 1 diabetes treated with the advanced hybrid closed loop (AHCL) system in relation to a sensor-augmented pump with low-glucose suspend (SAP-LGS) or predictive low-glucose suspend (SAP-PLGS). Materials and Methods: The data for 50 children and adolescents (age 5.5–19.6 years) with type 1 diabetes, receiving insulin through an AHCL system after being switched from SAP-LGS/PLGS systems, were included in the analysis. The SAP-LGS/PLGS records from 2 weeks preceding the AHCL connection were compared with the records from the first 4 weeks of AHCL use, represented as two separate 2-week intervals. Results: Significant improvements in most of the parameters, namely time spent in the range of 70–140 mg/dL (from 53.80% ± 12.35% to 61.70% ± 8.42%, P < 0.001) and 70–180 mg/dL (from 76.17% ± 10.28% to 81.32% ± 7.71%, P < 0.001), average sensor glucose (from 138.61 ± 16.66 to 130.02 ± 10.91 mg/dL, P < 0.001), and glucose management indicator (from 6.54% ± 0.45% to 6.27% ± 0.29%, P = 0.001), were observed within 2 weeks of switching to the AHCL. More evident improvements were observed for the parameters monitored at night than during the day. The potential limitations of this study were the short observation time, lack of glycated hemoglobin measurements, and no control arm. Conclusion: The AHCL system can significantly improve glycemic control even in well-controlled children and adolescents with type 1 diabetes by increasing the proportion of time spent in the narrower range of 70–140 mg/dL and decreasing the mean glucose concentration, especially during the night.

1 January 2023 in Pediatric Endocrinology Diabetes and Metabolism
Verified
Journal Article
Open access
SSSebastian Seget
Sebastian Seget
ATAnna Tekielak
Anna Tekielak
EREwa Rusak
Ewa Rusak
PJPrzemysława Jarosz-Chobot
Przemysława Jarosz-Chobot
Technological advances offer the opportunity to improve glycemic control and reduce the risk of complications and burden of type 1 diabetes while improving patient quality of life. Closed-loop insulin delivery systems take the technology to a larger scale by integrating CGM systems with an...

8 February 2024 in Frontiers in Endocrinology
Verified
Journal Article
Open access
PDF file
SSSebastian Seget
Sebastian Seget
ACAgata Chobot
Agata Chobot
MTMateusz Tarasiewicz
Mateusz Tarasiewicz
ABAnna Bielawska
Anna Bielawska
EREwa Rusak
Ewa Rusak
PJPrzemysława Jarosz-Chobot
Przemysława Jarosz-Chobot
Background and aims: MiniMed 780G is the first Advanced Hybrid Closed Loop (AHCL) system in Poland, approved in the EU in 2020. To date, observations of glycemic control up to 12 months have been published. This study aimed to analyze glycemic control and anthropometric parameters in children and adolescents with type 1 diabetes (T1D) after two years of using the AHCL system.Materials and methods: We prospectively collected anthropometric data, pump, and continuous glucose records of fifty T1D children (9.9 ± 2.4 years, 24 (48%) boys, T1D for 3.9 ± 2.56 years) using an AHCL system. We compared the two-week AHCL records obtained after AHCL enrollment with data 6, 12, and 24 months after starting AHCL.Results: Time in range (70-180 mg/dl) and BMI z-score did not change during the 2 years of observation (p>0.05). The percentage of autocorrection in total daily insulin increased significantly (p<0.005).Conclusion: Glycemic control in the investigated group of children with T1D treated with the AHCL system for 2 years remained stable. Children in this group maintained weight and optimal metabolic control, most likely due to autocorrection boluses.

25 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
EREwa Rusak
Ewa Rusak
NONatalia Ogarek
Natalia Ogarek
KWKarolina Wolicka
Karolina Wolicka
AMAnna Mrówka
Anna Mrówka
SSSebastian Seget
Sebastian Seget
PJPrzemyslawa Jarosz-Chobot
Przemyslawa Jarosz-Chobot
Quality of life (QoL) is an important parameter that affects the choice of therapy. Assessment of QoL and satisfaction with therapy using the rtCGM in children with T1D aged < 7 years was conducted. The study group consisted of 38 children with T1D aged < 7 years (34% aged 2–4, 66% aged 5–7 years), HbA1c: 6.53 ± 0.63%, duration of diabetes: 2.6 ± 1.6 years, treated with an rtCGM-augmented insulin pump for 1.92 ± 1.15 years. Two anonymous surveys were conducted: a. PedsQL3.0 diabetes standardized questionnaire—QoL assessment among age groups: 2–4/5–7 years. b. An original survey assessing the CGM use satisfaction. The mean scores in PedsQL3.0: communication 75%, worries 30%, treatment 70%, and problems associated with diabetes 65%. The QoL scale is: 0–19% very low, 20–39% low, 40–59% moderate, 60–79% high, 80–100% very high. The most frequently reported concerns were long-term diabetes complications and prick pain. Satisfaction with CGM use was high (68% in group aged 5–7 and 92% 2–4 years). Twenty-seven (71%) caregivers confirmed the positive effect of CGM on sleep. During the use of rtCGM a high quality of life was reported, and the quality of sleep in their caregivers was increased.

15 February 2023 in Healthcare
Verified
Journal Article
Open access
PDF file
SSSebastian Seget
Sebastian Seget
JWJulia Włodarczyk
Julia Włodarczyk
WLWanda Lutogniewska
Wanda Lutogniewska
EREwa Rusak
Ewa Rusak
MDMaria Dróżdż
Maria Dróżdż
PJPrzemyslawa Jarosz-Chobot
Przemyslawa Jarosz-Chobot
Technological progress in the treatment of type 1 diabetes requires doctors to use modern methods of insulin therapy in all areas of medicine that patients may come into contact with, including surgical interventions. The current guidelines indicate the possibility of using continuous subcutaneous insulin infusion in minor surgical procedures, but there are few reported cases of using a hybrid closed-loop system in perioperative insulin therapy. This case presentation focuses on two children with type 1 diabetes who were treated with an advanced hybrid closed-loop (AHCL) system during a minor surgical procedure. In the periprocedural period, the recommended mean glycemia and the time in range were maintained.