A method for the radiometric correction of wide field-of-view airborne imagery has been developed that accounts for the angular dependence of the path radiance and atmospheric transmittance functions to remove atmospheric and topographic effects. The first part of processing is the parametric geocoding of the scene to obtain a geocoded, orthorectified image and the view geometry (scan and azimuth angles) for each pixel as described in part 1 of this jointly submitted paper. The second part of the processing performs the combined atmospheric/ topographic correction. It uses a database of look-up tables of the atmospheric correction functions (path radiance, atmospheric transmittance, direct and diffuse solar flux) calculated with a radiative transfer code. Additionally, the terrain shape obtained from a digital elevation model is taken into account. The issues of the database size and accuracy requirements are critically discussed. The method supports all common types of imaging airborne optical instruments: panchromatic, multispectral and hyperspectral, including fore/aft tilt sensors covering the wavelength range 0.35-2.55 w m and 8-14 w m. The processor is designed and optimized for imaging spectrometer data. Examples of processing of hyperspectral imagery in flat and rugged terrain are presented. A comparison of ground reflectance measurements with surface reflectance spectra derived from airborne imagery demonstrates that an accuracy of 1-3% reflectance units can be achieved.
We present the Airborne Prism Experiment (APEX), its calibration and subsequent radiometric measurements as well as Earth science applications derived from this data. APEX is a dispersive pushbroom imaging spectrometer covering the solar reflected wavelength range between 372 and 2540nm with nominal 312 (max. 532) spectral bands. APEX is calibrated using a combination of laboratory, in-flight and vicarious calibration approaches. These are complemented by using a forward and inverse radiative transfer modeling approach, suitable to further validate APEX data. We establish traceability of APEX radiances to a primary calibration standard, including uncertainty analysis. We also discuss the instrument simulation process ranging from initial specifications to performance validation. In a second part, we present Earth science applications using APEX. They include geometric and atmospheric compensated as well as reflectance anisotropy minimized Level 2 data. Further, we discuss retrieval of aerosol optical depth as well as vertical column density of NOx, a radiance data-based coupled canopy–atmosphere model, and finally measuring sun-induced chlorophyll fluorescence (Fs) and infer plant pigment content. The results report on all APEX specifications including validation. APEX radiances are traceable to a primary standard with 625 for all spectral bands. Radiance based vicarious calibration is traceable to a secondary standard with ≤6.5% uncertainty. Except for inferring plant pigment content, all applications are validated using in-situ measurement approaches and modeling. Even relatively broad APEX bands (FWHM of 6nm at 760nm) can assess Fs with modeling agreements as high as R2=0.87 (relative RMSE=27.76%). We conclude on the use of high resolution imaging spectrometers and suggest further development of imaging spectrometers supporting science grade spectroscopy measurements
1 January 2002 in International Journal of Remote Sensing
An operational orthorectification solution in support of the combined geometric and radiometric processing of currently available imaging spectrometry data is presented. The described parametric geocoding procedure (PARGE) strictly considers the aircraft and terrain geometry parameters and uses a forward transformation algorithm to create orthorectified imaging spectrometry cubes. The implementation principles, the auxiliary data calibration strategies, and the workflow of the currently applied processor are discussed. The major error sources of the approach are identified, and possibilities are shown how to make the most out of the available auxiliary data Inertial Navigation System/Global Positioning System (INS/GPS) parameters. Results on HyMap and AVIRIS imaging spectrometry data show an absolute accuracy in the range of 1-3 pixels for this kind of imagery. The combination of PARGE with an atmospheric correction procedure is shown in part 2 to this paper. The depicted geo-atmospheric workflow is proposed as a standard processing approach for available and future imaging spectrometry data.
The automatic correction of atmospheric effects currently requires visible to short‐wave spectral bands (400–2500 nm) to derive high accuracy surface reflectance data. Common techniques employ spectral correlations of dark targets in the short‐wave infrared (SWIR, around 2.2 µm), blue (480 nm) and red (660 nm) regions to derive the aerosol optical depth. A large number of current Earth‐observing satellite sensors have only three or four spectral channels in the visible and near‐infrared (VNIR) region (400–1000 nm), making an automatic image‐based atmospheric correction very difficult. This contribution presents a new algorithm and first results with VNIR imagery. The method starts with the assumption of average clear atmospheric conditions (aerosol optical depth AOD = 0.27, corresponding to a visibility of 23 km) and calculates the surface reflectance in the red and near‐infrared (NIR) bands. The second step derives a mask of dark vegetation pixels. It is calculated using multiple thresholds of vegetation index combined with red and NIR surface reflectance values. Then the red band surface reflectance for the dark pixels is estimated from the NIR reflectance as ρred = 0.1 ρnir, from which the aerosol optical depth (or visibility) can be calculated. The core of the VNIR algorithm consists of two subsequent iteration loops (visibility and ρred) to improve the visibility estimate. Results of the VNIR method are presented for Landsat‐5 Thematic Mapper (TM) and Landsat‐7 Enhanced Thematic Mapper Plus (ETM+) imagery using only the first four bands. The performance of the method is compared to the established dark pixel technique where the SWIR bands are included. Results show that the deviation between both methods is usually less than 0.005 reflectance units if measured in terms of the scene‐average reflectance, indicating a useful potential for this approach.