Ryota Shimokura

Dr. Ryota Shimokura

Graduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Japan

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2022 in Audiology Research
Verified
Journal Article
Open access
PDF file
Ryota ShimokuraRyota Shimokura
Ryota Shimokura
The acoustical characteristics of auditory triggers often recommended to generate the autonomous sensory meridian response (ASMR) on Internet platforms were investigated by parameterizing their sound qualities following Zwicker’s procedure and calculating autocorrelation (ACF)/interaural cross-correlation (IACF) functions. For 20 triggers (10 human- and 10 nature-generated sounds), scores (on a five-point Likert scale) of the ASMR, perceived loudness, perceived pitch, comfort, and perceived closeness to the sound image were obtained for 26 participants by questionnaire. The results show that the human-generated sounds were more likely to trigger stronger ASMR than nature-generated sounds, and the primary psychological aspect relating to the ASMR was the perceived closeness, with the triggers perceived more closely to a listener having higher ASMR scores. The perceived closeness was evaluated by the loudness and roughness (among Zwicker’s parameter) for the nature-generated sounds and the interaural cross-correlation coefficient (IACC) (among ACF/IACF parameters) for the human-generated sounds. The nature-generated sounds with higher loudness and roughness and the human-generated sounds with lower IACC were likely to evoke the ASMR sensation.

3 June 2021 in Audiology Research
Verified
Journal Article
Open access
PDF file
Tadashi NishimuraTadashi Nishimura
Tadashi Nishimura
HHHiroshi Hosoi
Hiroshi Hosoi
Ryota ShimokuraRyota Shimokura
Ryota Shimokura
CMChihiro Morimoto
Chihiro Morimoto
TKTadashi Kitahara
Tadashi Kitahara
Cartilage conduction (CC) is a form of conduction that allows a relatively loud sound to be audible when a transducer is placed on the aural cartilage. The CC transmission mechanism has gradually been elucidated, allowing for the development of CC hearing aids (CC-HAs), which are clinically available in Japan. However, CC is still not fully understood. This review summarizes previous CC reports to facilitate its understanding. Concerning the transmission mechanism, the sound pressure level in the ear canal was found to increase when the transducer was attached to the aural cartilage, compared to an unattached condition. Further, inserting an earplug and injecting water into the ear canal shifted the CC threshold, indicating the considerable influence of cartilage–air conduction on the transmission. In CC, the aural cartilage resembles the movable plate of a vibration speaker. This unique transduction mechanism is responsible for the CC characteristics. In terms of clinical applications, CC-HAs are a good option for patients with aural atresia, despite inferior signal transmission compared to bone conduction in bony atretic ears. The advantages of CC, namely comfort, stable fixation, esthetics, and non-invasiveness, facilitate its clinical use.

17 June 2021 in Audiology Research
Verified
Journal Article
Open access
PDF file
SASakie Akasaka
Sakie Akasaka
Tadashi NishimuraTadashi Nishimura
Tadashi Nishimura
HHHiroshi Hosoi
Hiroshi Hosoi
OSOsamu Saito
Osamu Saito
Ryota ShimokuraRyota Shimokura
Ryota Shimokura
TKTadashi Kitahara
Tadashi Kitahara
Severe conductive hearing loss due to unilateral aural atresia leads to auditory and developmental disorders, such as difficulty in hearing in challenging situations. Bone conduction devices compensate for the disability but unfortunately have several disadvantages. The aim of this study was to evaluate the benefits of cartilage conduction (CC) hearing aids for speech perception in unilateral aural atresia. Eleven patients with unilateral aural atresia were included. Each participant used a CC hearing aid in the atretic ear. Speech recognition scores in the binaural hearing condition were obtained at low speech levels to evaluate the contribution of aided atretic ears to speech perception. Speech recognition scores were also obtained with and without presentation of noise. These assessments were compared between the unaided and aided atretic ear conditions. Speech recognition scores at low speech levels were significantly improved under the aided atretic ear condition (p < 0.05). A CC hearing aid in the unilateral atretic ear did not significantly improve the speech recognition score in a symmetrical noise presentation condition. The binaural hearing benefits of CC hearing aids in unilateral aural atresia were predominantly considered a diotic summation. Other benefits of binaural hearing remain to be investigated.

1 July 2021 in Audiology Research
Verified
Journal Article
Open access
PDF file
Ryota ShimokuraRyota Shimokura
Ryota Shimokura
Tadashi NishimuraTadashi Nishimura
Tadashi Nishimura
HHHiroshi Hosoi
Hiroshi Hosoi
Because cartilage conduction—the transmission of sound via the aural cartilage—has different auditory pathways from well-known air and bone conduction, how the output volume in the external auditory canal is stimulated remains unknown. To develop a simulator approximating the conduction of sound in ear cartilage, the vibrations of the pinna and sound in the external auditory canal were measured using pinna simulators made of silicon rubbers of different hardness (A40, A20, A10, A5, A0) as measured by a durometer. The same procedure, as well as a current calibration method for air conduction devices, was applied to an existing pinna simulator, the Head and Torso Simulator (hardness A5). The levels for vibration acceleration and sound pressure from these pinna simulators show spectral peaks at dominant frequencies (below 1.5 kHz) for the conduction of sound in cartilage. These peaks were likely to move to lower frequencies as hardness decreases. On approaching the hardness of actual aural cartilage (A10 to A20), the simulated levels for vibration acceleration and sound pressure approximated the measurements of human ears. The adjustment of the hardness used in pinna simulators is an important factor in simulating accurately the conduction of sound in cartilage.

13 July 2023 in Audiology Research
Verified
Journal Article
Open access
PDF file
Tadashi NishimuraTadashi Nishimura
Tadashi Nishimura
HHHiroshi Hosoi
Hiroshi Hosoi
Ryota ShimokuraRyota Shimokura
Ryota Shimokura
TKTadashi Kitahara
Tadashi Kitahara
A relatively loud sound is audible when a vibrator is attached to the aural cartilage. This form of conduction is referred to as cartilage conduction (CC). In Japan, a new type of hearing aid has been developed using CC and has been available in clinical practice since 2017. A clinical study conducted prior to its launch demonstrated its benefits, particularly in patients with aural atresia who were unable to use air conduction hearing aids. Several studies have been published on the benefits of CC hearing aids since their introduction into clinical practice. Most of the patients included in these studies had canal stenosis or aural atresia, and the purchase rates of CC hearing aids in these patients were relatively high. However, the number of patients with canal-open ears was small, with overall poor results in the trials, with the exception of patients with continuous otorrhea. CC hearing aids are considered a good option for compensating for hearing loss in ears with canal stenosis or atresia in both bilateral and unilateral cases. However, CC hearing aids are not currently considered the first choice for patients with a canal-open ear.

17 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Tadashi NishimuraTadashi Nishimura
Tadashi Nishimura
HHHiroshi Hosoi
Hiroshi Hosoi
CMChihiro Morimoto
Chihiro Morimoto
TOTadao Okayasu
Tadao Okayasu
Ryota ShimokuraRyota Shimokura
Ryota Shimokura
TKTadashi Kitahara
Tadashi Kitahara
The ear molds and shells of hearing devices are generally designed using ear impressions. Computed tomography (CT) can provide information concerning ear structure, which can be utilized in computer-aided design to create hearing devices. This study aimed to compare the differences in hearing devices designed using either ear impressions or CT images. The ear chip of a cartilage conduction (CC) hearing device was designed based on the ear impression and CT images of patients with aural atresia. Three patients with bilateral (n = 1) or unilateral (n = 2) aural atresia participated in this study. The aided thresholds and subjective evaluations were compared. There were no serious problems with the use of either device, and no remarkable differences were observed regarding their respective audiological and subjective benefits. Regarding the subjective patient preferences, the hearing aid with the device designed via CT imaging was better in three ears of two patients, whereas the wearing comfort of the transducer was better for the device designed via the ear impression. The subjective evaluation of appearance varied among the cases. Finally, a device that was designed using CT findings was purchased for one patient. CT images can be utilized in computer-aided design to create CC hearing devices.