Ricard Valero

Prof. Dr. Ricard Valero

orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2005 in American Journal of Transplantation
Verified
Journal Article
Open access
PDF file
MNMarc Net
Marc Net
RVRicard Valero
Ricard Valero
RARaul Almenara
Raul Almenara
PBPablo Barros
Pablo Barros
LCLluis Capdevila
Lluis Capdevila
JGJuan C. García‐Valdecasas
Juan C. García‐Valdecasas
We have evaluated the involvement of hepatic preconditioning mediators (adenosine, adenosine A1 and A2 receptors) during normothermic recirculation (NR) in a model of liver transplantation from non‐heart‐beating donor (NHBD) pigs. Application of NR after 20 min of warm ischemia (WI) reversed the lethal injury associated with transplantation of NHBD livers (achieving 5‐day survival and diminishing glutathione S‐transferase (GST), aspartate aminotransferase (AST) and hyaluronic acid (HA)). Adenosine administration prior to WI simulated the effect of NR. Measuring adenosine, we found that during NR, hepatic adenosine levels increased and xanthine levels decreased. Then when we blocked A2 receptors the effect of NR was abolished, whereas the blocking of A1 receptors further protected the liver. Furthermore, A2 blocking improved hepatic perfusion during NR whereas A1 blocking reduced it. The study suggests that NR has a preconditioning effect by maintaining adequate adenosine and xanthine levels. During NR, adenosine protects the liver through A2 activation and damages it through A1 activation although simultaneous stimulation of both receptors exerts a clear beneficial effect. The possible relation of NR mechanism with other preconditioning mediators such as cAMP and nitric oxide synthesis are discussed.

17 February 2016 in Transplant International
Verified
Journal Article
Open access
PDF file
BDBeatriz Domínguez-Gil
Beatriz Domínguez-Gil
JDJacques Duranteau
Jacques Duranteau
AMAlonso Mateos
Alonso Mateos
JNJose R. Núñez
Jose R. Núñez
GCGaelle Cheisson
Gaelle Cheisson
RMRafael Matesanz
Rafael Matesanz
The shortage of organs remains one of the biggest challenges in transplantation. To address this, we are increasingly turning to donation after circulatory death (DCD) donors and now in some countries to uncontrolled DCD donors. We consolidate the knowledge on uncontrolled DCD in Europe and provide recommendations and guidance for the development and optimization of effective uncontrolled DCD programmes.

1 July 2004 in Anesthesiology
Verified
Journal Article
Closed access
NFNeus Fàbregas
Neus Fàbregas
PGPedro Luis Gambus
Pedro Luis Gambus
RVRicard Valero
Ricard Valero
ECE. Carrero
E. Carrero
LSLydia Salvador
Lydia Salvador
EFEnrique Ferrer
Enrique Ferrer
Background: The probability of recovering consciousness in acute brain-injured patients depends on central nervous system damage and complications acquired during their stay in the intensive care unit. The objective of this study was to establish a relation between the Bispectral Index (BIS) and other variables derived from the analysis of the electroencephalographic signal, with the probability of recovering consciousness in patients in a coma state due to severe cerebral damage. Methods: Twenty-five critically ill, unconscious brain-injured patients from whom sedative drugs were withdrawn at least 24 h before BIS recording were prospectively studied. BIS, 95% spectral edge frequency, burst suppression ratio, and frontal electromyography were recorded for 20 min. The neurologic condition of the patients was measured according to the Glasgow Coma Score (GCS). Patients were followed up for assessment of recovery of consciousness for 6 months after the injury. The studied variables were compared between the group of patients who recovered consciousness and those who did not recover. Their predictive ability was evaluated by means of the Pk statistic. Univariate and multivariate logistic regression was used to model the relation between variables and probability of recovery of consciousness. Cross-validation was used to validate the proposed model. Results: There were statistically significant differences between the group of patients who recovered consciousness and those who did not with respect to BISmax, BISmin, BISmean, and BISrange, frontal electromyography, signal quality index values, and GCSBIS. The Pk (SE) values were 0.99 (0.01) for electromyelography, 0.96 (0.05) for BISmax, 0.92 (0.05) for BISmean, 0.92 (0.06) for BISrange, and 0.82 (0.09) for GCSBIS. The odds ratio for BISmax in the logistic regression model was 1.17 (95% confidence interval, 1.1-1.35). Cross-validation results reported a high-accuracy median absolute cross-validation performance error of 3.06% (95% confidence interval, 1-22.15%) and a low-bias median cross-validation performance error of 0.84% (0.56-2.12%). Conclusions: The study BIS and other electrophysiologic and clinical variables has enabled construction and cross-validation of a model relating BIS(max) to the probability of recovery of consciousness in patients in a coma state due to a severe brain injury, after sedation has been withdrawn.

1 August 2011 in British Journal of Anaesthesia
Verified
Journal Article
Closed access
PDF file
ALA. M. López
A. M. López
RVRicard Valero
Ricard Valero
PHP. Hurtado
P. Hurtado
PGPedro Luis Gambus
Pedro Luis Gambus
MPM. Pons
M. Pons
TAT. Anglada
T. Anglada
Background The laryngeal mask airway (LMA) has been successfully used in patients in the prone position either for rescue or elective airway management. The reusable Proseal™ LMA (PLMA) and the single use Supreme™ LMA (SLMA) have been reported to be suitable for this purpose but few comparative data are available. In this study, we compared the clinical use of both devices in adult patients anaesthetized in the prone position. Methods One hundred and twenty patients undergoing surgery in the prone position were randomized to receive either the PLMA or the SLMA for airway management. Patients positioned themselves in the prone position and after pre-oxygenation, anaesthesia was induced using a target-controlled i.v. infusion of propofol and remifentanil. All PLMAs and SLMAs were inserted by experienced anaesthetists using a guided and a standard technique respectively. Ease of facemask ventilation, time and number of attempts needed for insertion, quality of ventilation, airway seal pressure, fibreoptic view, and complications were compared. Results There were no differences between groups in insertion time or first attempt success (100% vs 98%). The PLMA required fewer manipulations (3% vs 15%; P=0.02) to achieve effective ventilation and provided a higher seal pressure (mean [sd] 31 [4] vs 27 [4] cm H2O; P<0.01). The fibrescopic view of the vocal cords was similar, although easier to achieve with the PLMA. The complication rate was low and similar between the groups. Blood was present on masks in 7% vs 8% and sore throat in 3% vs 5% of patients with the PLMA and SLMA, respectively. Conclusions Airway management in patients anaesthetized in the prone position was efficient with both devices, although the PLMA required fewer manipulations and achieved a higher seal pressure.

1 December 1999 in European Surgical Research
Verified
Journal Article
Closed access
PDF file
JGJ.C. García-Valdecasas
J.C. García-Valdecasas
JTJeanine Tabet
Jeanine Tabet
RVRicard Valero
Ricard Valero
RDR. Deulofeu
R. Deulofeu
PTPilar Taurá
Pilar Taurá
JVJ. Visa
J. Visa
The aim of this study was to assess liver viability after different periods of cardiac arrest and the predictive value of two markers of ischemia-reperfusion injury. Methods: A pig liver transplantation model of non-heart-beating donors was studied. Four donor groups were designed; three groups were submitted to different periods of cardiac arrest (20, 30 and 40 min), and the fourth group served as the control group (without cardiac arrest). In the non-heart-beating donor groups, normothermic recirculation was established 30 min prior to total body cooling. Aminotransferase, α-glutathione-S-transferase, and hyaluronic acid determinations as well as liver biopsies, were serially performed. Results: Although hepatocellular function could be preserved after 40 min of cardiac arrest, histological lesions at 5 days were considered irreversible due to the presence of a necrotic biliary tract. An overall significant relationship was found between the time period of cardiac arrest (20, 30 or 40 min) and the levels of hyaluronic acid (p = 0.004) or α-glutathione-S-transferase (p = 0.01) obtained during liver procurement and transplantation. Conclusions: The period of cardiac arrest is the determinant factor of liver viability after liver transplantation from non-heart-beating donors. As early markers of endothelial or hepatocellular damage, hyaluronic acid or α-glutathione-S-transferase levels may help to evaluate the ischemic injury of a potential donor.

1 July 1998 in Transplantation
Verified
Journal Article
Closed access
RVRicard Valero
Ricard Valero
JGJ C García-Valdecasas
J C García-Valdecasas
JTJ Tabet
J Tabet
PTP Taurá
P Taurá
RRR Rull
R Rull
JVJ Visa
J Visa
Our aim was to evaluate the hepatic blood flows and oxygen metabolism of non-heart-beating donor (NHBD) pigs, with the use of cardiopulmonary bypass (CPB) and normothermic recirculation (NR) before total body cooling, and its relationship with recipient survival. Thirty-five pigs were transplanted with an allograft from NHBDs. After warm ischemia (WI) time (20, 30, or 40 min), CPB and NR were run for 30 min. After this period, the animals were cooled to 15 degrees C. In the control group (20 min of WI), the period of NR was excluded. Liver procurement was then performed. Survival rate was 100% in the 20WI, 70% in the 30WI, and 50% in the 40WI. Control group survival rate was 0%. Hepatic artery blood flow and portal blood flow recovered during NR. Pump blood flow during CPB increased rapidly during NR and was significantly higher in the 20WI. When donors of the livers transplanted in "surviving pigs" (DSP) were compared with donors of the livers transplanted in "nonsurviving pigs" (DNSP), hepatic artery blood flow, portal blood flow, and pump blood flow were higher in the DSP. Hepatic oxygen extraction ratio increased in the three groups with respect to baseline values. Hepatic oxygen extraction ratio was lower in the 20WI than in the other groups and was lower in the DSP than in the DNSP. The use of a NR period before total body cooling improves survival of liver transplantation in NHBDs. Portal blood flow and pump blood flow measurements can predict the viability of the grafts.