As a typical brittle material, the tensile strength of concrete is much lower than its compressive strength. The main failure mode of concrete buildings under explosive and impact loading is spalling, so it is crucial to understand the dynamic tensile performance of concrete. This paper presents an experimental study on the dynamic tensile strength of steel-fiber-reinforced self-compacting concrete (SFRSCC). Specimens of two different self-compacting concrete (SCC) mixes (C40 and C60) and four different fiber volume fractions (0.5%, 1.0%, 1.5%, and 2.0%) are fabricated. Dynamic tensile strengths of SFRSCC are obtained using a modified Hopkinson bar system. The relationships between the dynamic tensile strength of the corresponding SCC mix, the quasi-static compressive strength, and the fiber volume fraction are discussed. An empirical equation is proposed. It is shown that SFRSCC with high compressive strength has higher dynamic tensile strength than low-strength SFRSCC for the same fiber content, and the dynamic tensile strength of SFRSCC possesses an approximately linear relation with the fiber volume fraction. The mechanism underlying this fiber-reinforcement effect is investigated.
1 January 2021 in Advances in Materials Science and Engineering
The dynamic behavior of steel fibre reinforced self‐compacting concrete (SFRSCC) was investigated by using a split Hopkinson pressure bar (SHPB). SFRSCC specimens with two strength classes of about 40 MPa and 60 MPa were prepared. Different steel fibre volume fractions were used varying from 0.5% to 2.0%. The tested strain rate ranged from about 50 to 240 s−1. Significant rate dependence was observed, and dynamic increase factor (DIF) was used to quantify the rate sensitivity. The results showed that both the matrix strength and fibre content had effect on the strain rate sensitivity of SFRSCC. A DIF formula was proposed for describing the dynamic strength of SFRSCC at high strain rates, and a dynamic damage constitutive model was derived to describe the stress‐strain relationship of SFRSCC. The parameters in the model were determined by fitting the experimental data. Good consistency between theoretical curves and experimental data was obtained.