Lukas Weiser

Dr. Lukas Weiser

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2017 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
LWLukas Weiser
Lukas Weiser
GHGerd Huber
Gerd Huber
KSKay Sellenschloh
Kay Sellenschloh
LVLennart Viezens
Lennart Viezens
KPKlaus Püschel
Klaus Püschel
WLWolfgang Lehmann
Wolfgang Lehmann

1 August 2021 in World Neurosurgery
Verified
Journal Article
Closed access
LVLennart Viezens
Lennart Viezens
KSKay Sellenschloh
Kay Sellenschloh
KPKlaus Püschel
Klaus Püschel
MMMichael M. Morlock
Michael M. Morlock
WLWolfgang Lehmann
Wolfgang Lehmann
LWLukas Weiser
Lukas Weiser

9 June 2018 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
LWLukas Weiser
Lukas Weiser
GHGerd Huber
Gerd Huber
KSKay Sellenschloh
Kay Sellenschloh
LVLennart Viezens
Lennart Viezens
KPKlaus Püschel
Klaus Püschel
WLWolfgang Lehmann
Wolfgang Lehmann

1 August 2016 in The Bone & Joint Journal
Verified
Journal Article
Closed access
LWLukas Weiser
Lukas Weiser
MDM. Dreimann
M. Dreimann
GHG. Huber
G. Huber
KSK. Sellenschloh
K. Sellenschloh
KPK. Püschel
K. Püschel
WLW. Lehmann
W. Lehmann
Aims: Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation. Materials and Methods: A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force. Results: Augmentation showed no significant increase in the mean cycles to failure and fatigue force (SHORT p = 0.067; EXTENDED p = 0.239). Extending the instrumentation resulted in a significantly increased number of cycles to failure and a significantly higher fatigue force compared with the SHORT instrumentation (EXTENDED non-augmented + 76%, p < 0.001; EXTENDED augmented + 87%, p < 0.001). Conclusion: The stabilising effect of cement augmentation of pedicle screws might not be as beneficial as expected from biomechanical pull-out tests. Lengthening the dorsal instrumentation results in a much higher increase of stability during fatigue testing in the osteoporotic spine compared with cement augmentation. Cite this article: Bone Joint J 2016;98-B:1099–1105.

17 September 2020 in European Spine Journal
Verified
Journal Article
Open access
PDF file
LWLukas Weiser
Lukas Weiser
KSKay Sellenschloh
Kay Sellenschloh
KPKlaus Püschel
Klaus Püschel
MMMichael M. Morlock
Michael M. Morlock
LVLennart Viezens
Lennart Viezens
GHGerd Huber
Gerd Huber
Purpose: Inadequate anchoring of pedicle screws in vertebrae with poor bone quality is a major problem in spine surgery. The aim was to evaluate whether a modified thread in the area of the pedicle could significantly improve the pedicle screw fatigue strength. Methods: Fourteen human cadaveric vertebral bodies (L2 and L3) were used for in vitro testing. Bone density (BMD) was determined by quantitative computed tomography. Vertebral bodies were instrumented by standard pedicle screws with a constant double thread on the right pedicle and a partial doubling of the threads–quad thread–(cortical thread) in the area of the pedicle on the left pedicle. Pulsating sinusoidal, cyclic load (0.5 Hz) with increasing peak force (100 N + 0.1 N/cycles) was applied orthogonal to the screw axis. The baseline force remained constant (50 N). Fatigue test was terminated after exceeding 5.4-mm head displacement (~ 20° screw tilting). Results: The mean fatigue load at failure was 264.9 N (1682 cycles) for the standard screws and was increased significantly to 324.7 N (2285 cycles) by the use of cortical threaded screws (p = 0.014). This effect is particularly evident in reduced BMD (standard thread 241.2 N vs. cortical thread 328.4 N; p = 0.016), whereas in the group of vertebrae with normal BMD no significant difference could be detected (standard thread 296.5 N vs. cortical thread 319.8 N; p = 0.463). Conclusions: Compared to a conventional pedicle screw, the use of a cortical threaded pedicle screw promises superior fatigue load in vertebrae with reduced bone quality.

6 May 2024 in Infection
Verified
Journal Article
Open access
PDF file
PRPaul Jonathan Roch
Paul Jonathan Roch
CECarolin Ecker
Carolin Ecker
KJKatharina Blanka Jäckle
Katharina Blanka Jäckle
MMMarc-Pascal Dr. Meier
Marc-Pascal Dr. Meier
MRMaximilian Reinhold
Maximilian Reinhold
LWLukas Weiser
Lukas Weiser
Purpose: Early diagnosis of surgical site infections (SSIs) could prevent surgical revision. Inflammatory markers (IMs), such as procalcitonin (PCT), interleukin-6 (IL-6), and tumor necrosis factor α (TNF-α), seem more accurate in diagnosing SSI than C-reactive protein (CRP) and white blood cell (WBC) count. The aim was to compare the predictive values of CRP, WBC count, PCT, IL-6, and TNF-α in SSI detection. Methods: A total of 130 patients undergoing dorsal spondylodesis from 2019 to 2024 were enrolled in a prospective diagnostic study at a maximum care spine center. IMs were measured preoperatively and on the postoperative days (PODs) 1, 2, 3, 5, and 7. Patients with high suspicion of SSI underwent revision surgery. SSI was diagnosed when the microbiological evidence was positive. Patients were divided a posteriori into the non-infection and infection groups. Results: IMs of 118 patients (66.9 ± 13.0 years, 61.0% females) were measured. Fifteen of the 118 patients (12.7%) developed an SSI. The groups differed with respect to existing hypertension, number of instrumented segments, region of surgery, CRPPOD1,7, PCTPOD7, and IL-6POD3,5,7. Binary logistic regression for SSI detection including these parameters showed an area under the curve (AUC) of 0.88 (95% CI 0.79–0.98; P < 0.001). The main effect for SSI detection was maintained by IL-6POD7 (odds ratio = 1.13; 95% CI 1.05–1.23; P = 0.001), which itself showed an AUC of 0.86 (95% CI 0.75–0.97). Conclusion: Compared to CRP, WBC count, PCT, and TNF-α, IL-6 seems to be the critical IM for the early detection of an SSI. Trial registration: drks.de: DRKS00033773, date of registration: 29.02.2024, retrospectively registered; Postoperative Markers of Inflammation in Spine Surgery (POMIS) Trial.