Sameer Al-Maisary

Dr. Sameer Al-Maisary

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2019 in Journal of Cardiac Surgery
Verified
Journal Article
Closed access
PDF file
SASameer Al-Maisary
Sameer Al-Maisary
GRGabriele Romano
Gabriele Romano
MKMatthias Karck
Matthias Karck
RSRaffaele Simone
Raffaele Simone

30 January 2017 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
SASameer Al-Maisary
Sameer Al-Maisary
SESandy Engelhardt
Sandy Engelhardt
BGBastian Graser
Bastian Graser
IWIvo Wolf
Ivo Wolf
MKMatthias Karck
Matthias Karck
RSRaffaele De Simone
Raffaele De Simone
Ring sizing for mitral valve annuloplasty is conventionally done intraoperatively using specific ‘sizer’ instruments, which are placed onto the valve tissue. This approach is barely reproducible since different sizing strategies have been established among surgeons. The goal of this study is to virtually apply different sizing methods on the basis of pre-repair echocardiography to find out basic differences between sizing strategies. In three-dimensional echocardiographs of 43 patients, the mitral annulus and the contour of the anterior mitral leaflet were segmented using MITK Mitralyzer software. Similarly, three-dimensional virtual models of Carpentier-Edwards Physio II annuloplasty rings and their corresponding sizers were interactively generated from computer tomography images. For each patient, the matching annuloplasty ring was selected repeatedly according to popular sizing strategies, such as the height of anterior mitral leaflet, the intercommissural distance and the surface area of anterior mitral leaflet. The areas of the selected rings were considered as the neo-surface area of the mitral annulus after implantation. The sizing of the mitral valve according to the height of anterior mitral leaflet (mean ring size = 29.9 ± 3.90), intercommissural distance (mean ring size = 37.5 ± 1.92) or surface area of anterior mitral leaflet (mean ring size = 32.7 ± 3.3) led to significantly different measurements (p ≤ 0.01). In contrary to intercommissural distance, height and surface area of the anterior mitral leaflet exhibited significant variations between the patients (p ≤ 0.01). The sizing according to the height of anterior mitral leaflet led to the maximal reduction of the mitral annulus surface area followed by the sizing according to the surface area of anterior mitral leaflet and finally by the intercommissural distance. This novel comprehensive computer-based analysis reveals that the surveyed sizing methods led to the selection of significantly different annuloplasty rings and therefore underscore the ambiguity of routinely applied annuloplasty sizing strategies.

30 October 2021 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
SASameer Al-Maisary
Sameer Al-Maisary
JKJamila Kremer
Jamila Kremer
GRGabrielle Romano
Gabrielle Romano
MKMatthias Karck
Matthias Karck
RSRaffaele De Simone
Raffaele De Simone
Background: Lead laser extraction is a well-established method for removing unwanted leads with low morbidity and mortality. Objective: In this observational study, we documented our experience with venous occlusion after lead laser extraction. Methods: Retrospective data of patients who underwent lead laser extraction between May 2010 and August 2018 was analyzed. Two subgroups of patients were identified. First group represented patients after lead laser extraction who suffered postoperative venous occlusion. Second group represents patients after lead laser extraction, who has documented patent venous access after lead laser extraction. Results: 219 patients underwent percutaneous laser lead extraction. The mean age of patients was 65 ± 14 years. Of these patients, 74% were male. The Most common indication for extraction was Nonfunctional lead (45.2%, n = 99) followed by pocket infection with 33.8% and endocarditis (17.3%). A total number of 447 leads underwent laser extraction. In 7.8% of the patients, lead extraction was partially successful and lead extraction was not successful in only 2.3% of the patients. Only 13 patients developed a documented venous occlusion postoperatively and 26 patients has documented absence of venous occlusion, of whom 17 were under oral anticoagulation. Conclusion: Lead laser extraction may lead to venous occlusion, which is mostly asymptomatic but it prevents future lead implantation. The use of oral anticoagulant may prevent postoperative venous occlusion.

14 May 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SASameer Al-Maisary
Sameer Al-Maisary
GRGabriele Romano
Gabriele Romano
MKMatthias Karck
Matthias Karck
RSRaffaele De Simone
Raffaele De Simone
JKJamila Kremer
Jamila Kremer
The implantation of cardiac implantable electronic devices (CIED) has increased in the last decades with improvement in the quality of life of patients with cardiac rhythm disorders. The presence of bilateral subclavian, innominate or superior vena cava obstruction is a major limitation to device revision and/or upgrade. This is retrospective study of patients who underwent laser-assisted lead extraction (LLE) (GlideLight laser sheath, Spectranetics Corporation, Colorado Springs, USA) with lead revision or upgrade using the laser sheath as a guide rail. Patients with known occlusion, severe stenosis or functional obstruction of the venous access vessels with indwelling leads were included in this study. 106 patients underwent percutaneous LLE with lead revision and/or upgrade. Preoperative known complete occlusion or severe stenosis of access veins was present in 23 patients (21.5%). More patients with implantable cardioverter-defibrillator (ICD) underwent LLE (64.1%) than patients with CRT-Ds (24.5%) and pacemaker patients (11.3%). In total 172 leads were extracted: 79 (45.9%) single-coil defibrillator leads, 35 (20.3%) dual-coil defibrillator leads, 31 (18.0%) right atrial leads, 24 (13.9%) right ventricular leads and three (1.7%) malfunctional coronary sinus left ventricular pacing leads. The mean age of leads was 99.2±65.6 months. The implantation of new leads after crossing the venous stenosis/obstruction was successful in 98 (92.4%) cases. Postoperative complications were pocket hematoma in two cases and wound infection in one case. No peri-operative and no immediate postoperative death was recorded. One intraoperative superior vena cava tear was treated by immediate thoracotomy and surgical repair. In a single-center study on LLE in the presence of supra-cardiac occlusion of the central veins for CIED lead upgrade and revision we could demonstrate a low procedural complication rate with no procedural deaths. Most of the leads could be completely extracted to revise or upgrade the system. Our study showed a low complication rate, with acceptable mortality rates.

1 March 2017 in The Journal of Cardiovascular Surgery
Verified
Journal Article
Closed access
SASameer Al-Maisary
Sameer Al-Maisary
BGBastian Graser
Bastian Graser
SESandy Engelhardt
Sandy Engelhardt
IWIvo Wolf
Ivo Wolf
MKMatthias Karck
Matthias Karck
RSRaffaele De Simone
Raffaele De Simone
Article: The geometrical effect of different annuloplasty rings on mitral valve annulus - The Journal of Cardiovascular Surgery 2017 June;58(3):481-8 - Minerva Medica - Journals

15 April 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SASameer Al-Maisary
Sameer Al-Maisary
MMMigdat Mustafi
Migdat Mustafi
GRGabriele Romano
Gabriele Romano
MKMatthias Karck
Matthias Karck
Rawa ArifRawa Arif
Rawa Arif
Mario Jesús Guzmán-RuvalcabaMario Jesús Guzmán-Ruvalcaba
Mario Jesús Guzmán-Ruvalcaba
Background: The global demographic shift towards an aging population has driven a steady, exponential increase in the utilization of cardiac implantable electronic devices (CIEDs). Consequently, device-related infectious complications have emerged as a leading cause of morbidity and healthcare expenditure. Patients in their eighth decade of life—octogenarians (aged 80–90 years)—represent an exceptionally high-risk demographic due to the compounding factors of physiological frailty, immunosenescence, and complex multi-morbidity. Despite this growing demographic, their specific clinical presentations, microbiological profiles, and procedural outcomes following infection remain poorly defined in the current literature. This study aimed to comprehensively compare the clinical characteristics, pathogen distribution, and in-hospital outcomes of CIED infections in an octogenarian cohort against a younger patient population. Methods: We conducted a robust retrospective cohort analysis of 383 consecutive patients treated for confirmed CIED infections at one major tertiary referral center (Heidelberg University Hospital) between January 2002 and December 2022. The cohort was stratified by age into octogenarians (n = 76) and a younger control group (n = 307). We systematically extracted and compared data regarding baseline clinical presentation, chronic comorbidities, detailed microbiological cultures (pocket, blood, and extracted leads), and definitive in-hospital outcomes, primarily mortality and length of stay. Results: The octogenarian cohort exhibited a significantly heavier comorbidity burden, notably higher rates of coronary artery disease (51.3% vs. 29.6%, p < 0.001), systemic hypertension (55.3% vs. 38.1%, p = 0.007), and chronic obstructive pulmonary disease (7.9% vs. 1.6%, p = 0.003). Furthermore, therapeutic systemic anticoagulant use was substantially more prevalent in the elderly group (60.5% vs. 45.0%, p = 0.015). Octogenarians presented overwhelmingly with localized generator pocket infections (73.0% vs. 30.0%, p < 0.001) but paradoxically also demonstrated higher rates of systemic bacteremia and sepsis (26.3% vs. 15.0%, p = 0.019). Microbiological analysis revealed a unique pathogen profile, with Staphylococcus capitis found with significantly higher frequency in the generator pockets of the elderly cohort. Remarkably, despite possessing a higher average lead burden (2.1 vs. 1.2 leads) and extreme comorbidity profiles, octogenarians demonstrated no statistically significant differences in in-hospital mortality (3.9% vs. 4.2%, p = 1.000) or overall length of hospital stay (14.7 vs. 17.2 days, p = 0.386) when compared to the younger cohort. Conclusions: Octogenarians suffering from CIED infections display highly distinct clinical and microbiological profiles, characterized predominantly by elevated rates of localized pocket infections, specific opportunistic pathogens, and a severe underlying comorbidity burden. Crucially, our findings indicate that with the application of modern extraction and management protocols, advanced age alone does not intrinsically correlate with increased in-hospital mortality. Future prevention and perioperative management strategies tailored to this rapidly expanding demographic must heavily prioritize the mitigation of pocket-related complications, particularly considering the high prevalence of concurrent anticoagulation therapy.