Barry A. Siegel

Dr. Barry A. Siegel


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2023 in Journal of Urology
Verified
Journal Article
Open access
AJAshesh B. Jani
Ashesh B. Jani
GRGregory C Ravizzini
Gregory C Ravizzini
BGBenjamin A. Gartrell
Benjamin A. Gartrell
BSBarry A. Siegel
Barry A. Siegel
PTPrzemyslaw Twardowski
Przemyslaw Twardowski
KZKatherine Zukotynski
Katherine Zukotynski
SPOTLIGHT (NCT04186845) evaluated diagnostic performance and safety of radiohybrid (rh) 18F-rhPSMA-7.3, a novel high-affinity PET radiopharmaceutical. Men with prostate cancer recurrence underwent PET/CT 50-70 minutes after intravenous administration of 296±20% MBq 18F-rhPSMA-7.3. To assess the co-primary endpoints (verified detection rate [VDR] and combined region-level positive predictive value [crPPV]), 3 blinded, independent central readers evaluated the scans. VDR is equivalent to the overall detection rate (DR) x PPV. Standard of Truth (SoT) was established for each patient using histopathology or confirmatory imaging. Statistical thresholds (lower bounds of the confidence intervals) of 36.5% and 62.5% were prespecified for VDR and crPPV, respectively. Additional endpoints included DR, VDR and crPPV in patients with histopathology SoT, and safety. The overall 18F-rhPSMA-7.3 DR among all 389 patients with an evaluable scan was 83% (majority read). Among the 366 patients (median PSA, 1.27 ng/mL) for whom a SOT (histopathology [n=69]/confirmatory imaging only [n=297]) was available, VDR ranged from 51% (95%CI, 46.1-56.6) to 54% (95%, 48.8-59.3), exceeding the prespecified statistical threshold. crPPV ranged from 46% (95%CI, 42.0-50.3%) to 60% (95%CI, 55.1-65.5%) across the readers, not meeting the threshold. In the subset of patients with histopathology SoT, the VDR and crPPV were both above the prespecified thresholds (majority read, 81% [95%CI, 69.9-89.6] and 72% [95%CI, 62.5-80.7], respectively). No significant safety concerns were identified. 18F-rhPSMA-7.3 offers a clinically meaningful VDR for localization of recurrent prostate cancer. Despite missing the co-primary endpoint of crPPV, the totality of the data support the potential clinical utility of 18F-rhPSMA-7.3.

11 January 2018 in Journal of Kidney Cancer
Verified
Journal Article
Open access
PDF file
DFDominique Fuser
Dominique Fuser
MHMatthew L. Hedberg
Matthew L. Hedberg
LDLouis P. Dehner
Louis P. Dehner
FDFarrokh Dehdashti
Farrokh Dehdashti
BSBarry A. Siegel
Barry A. Siegel
Sarcomatoid renal cell carcinoma (sRCC) is a highly aggressive form of dedifferentiated renal cell carcinoma. We report a 62-yearold man who presented with respiratory symptoms and a lung mass on chest computed tomography (CT). The patient underwent positron emission tomography/computed tomography (PET/CT) with 18F-fluorodeoxyglucose (18F-FDG) and was found to have extensive metastatic disease. Based on the history and imaging findings, there were possible primary malignancies, including bronchogenic carcinoma, melanoma, or an aggressive lymphoma. An excisional biopsy surprisingly revealed a high-grade sarcomatoid carcinoma with no evidence of differentiation, and immunohistochemical (IHC) studies showed that the tumor cells were positive for markers of genitourinary origin (PAX-8 and vimentin). The histologic and IHC results, along with multiple FDG-avid exophytic lesions in both kidneys, were considered diagnostic of sRCC. Here we have highlighted the potential role of 18F-FDG-PET-CT in patients with sRCC, discussed the diagnostic challenges, and presented a brief review.

1 March 2021 in American Journal of Roentgenology
Verified
Journal Article
Closed access
BSBarry A. Siegel
Barry A. Siegel
DSDavid M. Schuster
David M. Schuster
BSBital Savir-Baruch
Bital Savir-Baruch

20 March 2025 in arXiv
Verified
Preprint
Open access
PDF file
ZYZitong Yu
Zitong Yu
NCNu Ri Choi
Nu Ri Choi
ZYZezhang Yang
Zezhang Yang
NONancy A. Obuchowski
Nancy A. Obuchowski
BSBarry A. Siegel
Barry A. Siegel
AJAbhinav K. Jha
Abhinav K. Jha
A recently proposed scatter-window and deep learning-based attenuation compensation (AC) method for myocardial perfusion imaging (MPI) by single-photon emission computed tomography (SPECT), namely CTLESS, demonstrated promising performance on the clinical task of myocardial perfusion defect detection with retrospective data acquired on SPECT scanners from a single vendor. For clinical translation of CTLESS, it is important to assess the generalizability of CTLESS across different SPECT scanners. For this purpose, we conducted a virtual imaging trial, titled in silico imaging trial to assess generalizability (ISIT-GEN). ISIT-GEN assessed the generalizability of CTLESS on the cardiac perfusion defect detection task across SPECT scanners from three different vendors. The performance of CTLESS was compared with a standard-of-care CT-based AC (CTAC) method and a no-attenuation compensation (NAC) method using an anthropomorphic model observer. We observed that CTLESS had receiver operating characteristic (ROC) curves and area under the ROC curves similar to those of CTAC. Further, CTLESS was observed to significantly outperform the NAC method across three scanners. These results are suggestive of the inter-scanner generalizability of CTLESS and motivate further clinical evaluations. The study also highlights the value of using in silico imaging trials to assess the generalizability of deep learning-based AC methods feasibly and rigorously.