György Szabó

Prof. Dr. György Szabó

Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Budapest, Hungary

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Maxillofacial Plastic and Reconstructive Surgery
Verified
Journal Article
Open access
PDF file
György SzabóGyörgy Szabó
György Szabó
JBJózsef Barabás
József Barabás
SBSándor Bogdán
Sándor Bogdán
ZNZsolt Németh
Zsolt Németh
BSBéla Sebők
Béla Sebők
GKGábor Kiss
Gábor Kiss
Over the past 30–40 years, various carbon implant materials have become more interesting, because they are well accepted by the biological environment. The traditional carbon-based polymers give rise to many complications. The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon). The aim of this study is to present the long-term clinical results of carbon/carbon implants, and the results of the scanning electron microscope and energy dispersive spectrometer investigation of an implant retrieved from the human body after 8 years. Mandibular reconstruction (8–10 years ago) was performed with pure (99.99 %) carbon implants in 16 patients (10 malignant tumours, 4 large cystic lesions and 2 augmentative processes). The long-term effect of the human body on the carbon/carbon implant was investigated by comparing the structure, the surface morphology and the composition of an implant retrieved after 8 years to a sterilized, but not implanted one. Of the 16 patients, the implants had to be removed earlier in 5 patients because of the defect that arose on the oral mucosa above the carbon plates. During the long-term follow-up, plate fracture, loosening of the screws, infection or inflammations around the carbon/carbon implants were not observed. The thickness of the carbon fibres constituting the implants did not change during the 8-year period, the surface of the implant retrieved was covered with a thin surface layer not present on the unimplanted implant. The composition of this layer is identical to the composition of the underlying carbon fibres. Residual soft tissue penetrating the bulk material between the carbon fibre bunches was found on the retrieved implant indicating the importance of the surface morphology in tissue growth and adhering implants. The surface morphology and the structure were not changed after 8 years. The two main components of the implant retrieved from the human body are still carbon and oxygen, but the amount of oxygen is 3–4 times higher than on the surface of the reference implant, which can be attributed to the oxidative effect of the human body, consequently in the integration and biocompatibility of the implant. The clinical conclusion is that if the soft part cover is appropriate, the carbon implants are cosmetically and functionally more suitable than titanium plates.

12 April 2023 in Coatings
Verified
Journal Article
Open access
PDF file
GPGabor Tamas Pinter
Gabor Tamas Pinter
BTBalint Trimmel
Balint Trimmel
MKMárton Kivovics
Márton Kivovics
THTamas Huszar
Tamas Huszar
ZNZsolt Nemeth
Zsolt Nemeth
György SzabóGyörgy Szabó
György Szabó
Tantalum and titanium are two of the most popular materials used in dental implants today. These materials are highly biocompatible, durable, and long-lasting, making them ideal for use in dental and maxillofacial implants. The ceramic oxide layer that covers the surface of titanium and tantalum implants (TiO2,TaO2) is formed through an electrochemical growth from the inside of the metal and subsequently altered through heat treatment. The aim of this retrospective study was to evaluate the long-term survival of the oxide ceramic-coated titanium dental implants. The secondary purpose was to evaluate the production process and the cost of the coated tantalum and titanium implants, and to complete these retrospective investigations with the results of our previous work concerning the titanium oxide coating. The structural, physical, and chemical properties as well as the corrosion resistance of the Ti/TiO2 surface were investigated; XPS, SIMS, and XRD techniques were used. Patients who received tantalum oxide-coated (Ta/TaO2) dental implants, titanium oxide-coated (Ti/TiO2) dental implants, or titanium oxide-coated (Ti/TiO2) osteosynthesis plates for rehabilitation at the Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University between 1995 and 2005 were included in this retrospective study. Data collection was performed between June 2021 and December 2021. The cost of the tantalum implant was 25 times that of the titanium implant. Only 21 implants were inserted in 10 patients. The survival rate (min. 16 years) was 95%. Twelve patients with a total of sixty-four TiO2-coated implants were observed. The mean implant survival rate was 95%. Our conclusion was that, regardless of the shape of the implant, the Ti/TiO2 coating proved its excellent durability over the years. The “tantalum issue” is increasingly relevant nowadays, since instead of implants made of pure tantalum metal, implants with a porous tantalum surface have come to the fore.

13 April 2018 in Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
PDF file
ZFZoltán Fábián
Zoltán Fábián
György SzabóGyörgy Szabó
György Szabó
CPCecilia Petrovan
Cecilia Petrovan
KHKarin Ursula Horvath
Karin Ursula Horvath
BBBotond Babicsák
Botond Babicsák
SBSándor Bogdán
Sándor Bogdán