Uberto Bortolotti

Prof. Uberto Bortolotti

orcid

Research Focus & Metrics

Academic Career Length

46Years (1981-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2012 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
UBUberto Bortolotti
Uberto Bortolotti
AMAldo D. Milano
Aldo D. Milano
RFRobert W.M. Frater
Robert W.M. Frater

5 November 2019 in Journal of Cardiac Surgery
Verified
Journal Article
Closed access
PDF file
AMAndrea De Martino
Andrea De Martino
RMRiccardo Morganti
Riccardo Morganti
GFGiosuè Falcetta
Giosuè Falcetta
GSGiovanni Scioti
Giovanni Scioti
AMAldo Domenico Milano
Aldo Domenico Milano
UBUberto Bortolotti
Uberto Bortolotti

27 August 2016 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
IFIacopo Fabiani
Iacopo Fabiani
CSCristian Scatena
Cristian Scatena
Chiara Maria MazzantiChiara Maria Mazzanti
Chiara Maria Mazzanti
LCLorenzo Conte
Lorenzo Conte
NPNicola Riccardo Pugliese
Nicola Riccardo Pugliese
VBVitantonio Di Bello
Vitantonio Di Bello
Myocardial fibrosis (MF) is a deleterious consequence of aortic valve stenosis (AVS). Global longitudinal strain (GLS) is a novel left ventricular (LV) functional parameter potentially useful to non-invasively estimate MF. MicroRNAs (miRNAs) are non-coding small ribonucleic acids (RNA) modulating genes function, mainly through RNA degradation. miRNA-21 is a biomarker associated with MF in pressure overload. The aim of the present study was to find an integrated algorithm for detection of MF using a combined approach with both bio- and functional markers. Thirty-six patients (75.2 ± 8 y.o.; 63 % Female) with severe AVS and preserved LV ejection fraction (EF), candidate to surgical aortic valve replacement (sAVR) were enrolled. Clinical, bio-humoral evaluation (including plasmatic miRNA-21 collected using specific tubes, PAXgene, for stabilization of peripheral RNA) and a complete echocardiographic study, including GLS and septal strain, were performed before sAVR. Twenty-eight of those patients underwent sAVR and, in 23 of them, an inter-ventricular septum biopsy was performed. Tissues were fixed in formalin and embedded in paraffin. Sections were stained with Hematoxylin and Eosin for histological evaluation and with histochemical Masson trichrome for collagen fibers. The different components were calculated and expressed as micrometers2. To evaluate tissue miRNA components, sections 2-μm thick were cut using a microtome blade for each slide. Regression analysis was performed to test association between dependent variable and various predictors included in the model. Despite a preserved EF (66 ± 11 %), patients presented altered myocardial deformation parameters (GLS −14,02 ± 3.8 %; septal longitudinal strain, SSL −9.63 ± 2.9 %; septal longitudinal strain rate, SL-Sr −0.58 ± 0.17 1/s; Septal Longitudinal early-diastolic strain rate, SL-SrE 0.62 ± 0.32 1/s). The extent of MF showed an inverse association with both GLS and septal longitudinal deformation indices (GLS: R2 = 0.30; p = 0.02; SSL: R2 = 0.36; p = 0.01; SL-Sr: R2 = 0.39; p < 0.001; SL-SrE: R2 = 0.35; p = 0.001). miRNA-21 was mainly expressed in fibrous tissue (p < 0.0001). A significant association between MF and plasmatic miRNA-21, alone and weighted for measures of structural (LVMi R2 = 0.50; p = 0.0005) and functional (SSL R2 = 0.35; p = 0.006) remodeling, was found. In AVS, MF is associated with alterations of regional and global strain. Plasmatic miRNA-21 is directly related to MF and associated with LV structural and functional impairment.

14 September 2021 in Journal of Cardiac Surgery
Verified
Journal Article
Open access
PDF file
UBUberto Bortolotti
Uberto Bortolotti
IVIgor Vendramin
Igor Vendramin
ALAndrea Lechiancole
Andrea Lechiancole
SSSandro Sponga
Sandro Sponga
APAngela Pucci
Angela Pucci
ULUgolino Livi
Ugolino Livi
Background and aim Blood cysts of cardiac valves are generally seen in newborns and infants and very rarely in adults. Although in most cases they are incidental findings they may be associated to severe cardiac or systemic complications. This study analyzes incidence, presentation, and treatment of valvular blood cysts in adults. Methods A review of the pertinent literature through a search mainly on PubMed and Medline was performed. Results In patients ≥18 years of age, our search disclosed 54 patients with mitral blood cysts (mean age, 48 ± 18 years), 9 with a tricuspid valve cyst (mean age, 67 ± 15 years), 3 with a blood cyst on the pulmonary valve (age 31, 43, and 44 years), and 1 aortic valve cyst in a 22-year-old man. Most patients were asymptomatic while stroke, syncope, or myocardial infarction occurred in six patients with a mitral valve cyst. Blood cysts were removed surgically in 70% of patients with a mitral cyst, in 55% with a tricuspid cyst, and in all those with a pulmonary or aortic cyst. At histology, the cyst wall was composed mainly by fibrous tissue and with the inner surface lined with typical endothelium. Conclusions Blood cysts of cardiac valves are rare in adults but may cause life-threatening complications, particularly when located on the mitral valve. For such reason, surgical removal appears advisable, with low-risk procedures. Widespread use of multimodality imaging techniques will most likely increase the number of valvular blood cysts diagnosed also in adults.

1 February 2016 in Texas Heart Institute Journal
Verified
Journal Article
Closed access
MCMichele Celiento
Michele Celiento
SBStefania Blasi
Stefania Blasi
AMAndrea De Martino
Andrea De Martino
SPStefano Pratali
Stefano Pratali
AMAldo D. Milano
Aldo D. Milano
UBUberto Bortolotti
Uberto Bortolotti
We reviewed the cases of 100 patients (mean age, 73 ± 10 yr; 64 men) who had mitral valve replacement with a Medtronic Mosaic porcine bioprosthesis from 1995 through 2011. The mean New York Heart Association (NYHA) class was 3 ± 0.7, and 52 patients were in atrial fibrillation. Prosthetic sizes were chiefly 27 mm (50 patients) and 29 mm (40 patients). Follow-up ended in December 2012 and is 97% complete, with a cumulative duration of 611 patient-years (mean duration, 6 ± 4.6 yr; maximum, 17.7 yr). The early mortality rate was 10% (6% in elective patients); late deaths occurred in 31 patients (5 valve-related). Actuarial survival rates at 5, 10, and 15 years were 74% ± 5%, 50% ± 6%, and 37% ± 8%. The mean NYHA class in survivors was 1.4 ± 0.6 (P <0.0001). Thromboembolic episodes occurred in 4 patients, with an actuarial freedom at 15 years of 91% ± 5%. No cases of endocarditis were observed. Four patients needed reoperation, 2 for structural failure, and 1 each for perivalvular leakage and valve thrombosis. Actuarial freedom from structural failure and from reoperation, respectively, was 93% ± 5% and 91% ± 5% at 15 years. Echocardiographic follow-up in 24 patients with 27-mm prostheses showed a mean gradient of 5 ± 1.7 mmHg and an effective orifice area of 1.57 ± 0.3 cm2; in 16 patients with 29-mm prostheses, the mean gradient was 4.5 ± 1.9 mmHg, and the effective orifice area, 1.63 ± 0.4 cm2. During nearly 17 years of follow-up, the Mosaic bioprosthesis has shown good overall clinical and hemodynamic performance after mitral valve replacement.

Verified
Journal Article
Open access
PDF file
Igor VendraminIgor Vendramin
Igor Vendramin
ALAndrea Lechiancole
Andrea Lechiancole
DPDaniela Piani
Daniela Piani
Gaetano NuciforaGaetano Nucifora
Gaetano Nucifora
GBGiovanni Benedetti
Giovanni Benedetti
Ugolino LiviUgolino Livi
Ugolino Livi
Sutureless and rapid-deployment bioprostheses have been introduced as alternatives to traditional prosthetic valves to reduce cardiopulmonary and aortic cross-clamp times during aortic valve replacement. These devices have also been employed in extremely demanding surgical settings, as underlined in the present review. Searches on the PubMed and Medline databases aimed to identify, from the English-language literature, the reported cases where both sutureless and rapid-deployment prostheses were employed in challenging surgical situations, usually complex reoperations sometimes even performed as bailout procedures. We have identified 25 patients for whom a sutureless or rapid-deployment prosthesis was used in complex redo procedures: 17 patients with a failing stentless bioprosthesis, 6 patients with a failing homograft, and 2 patients with the failure of a valve-sparing procedure. All patients survived reoperation and were reported to be alive 3 months to 4 years postoperatively. Sutureless and rapid-deployment bioprostheses have proved effective in replacing degenerated stentless bioprostheses and homografts in challenging redo procedures. In these settings, they should be considered as a valid alternative not only to traditional prostheses but also in selected cases to transcatheter valve-in-valve solutions.