Adrià Miró Alba

Mr. Adrià Miró Alba

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Human Movement Science
Verified
Journal Article
Closed access
Jose MoralesJose Morales
Jose Morales
Bernat BuscàBernat Buscà
Bernat Buscà
Monica Solana-TramuntMonica Solana-Tramunt
Monica Solana-Tramunt
AAAdrià Miró Alba
Adrià Miró Alba

AAAdrià Miró Alba
Adrià Miró Alba
Bernat BuscàBernat Buscà
Bernat Buscà
Joan Aguilera-CastellsJoan Aguilera-Castells
Joan Aguilera-Castells
Jordi Arboix-AlióJordi Arboix-Alió
Jordi Arboix-Alió
The purpose of the present systematic review was to determine the acute effects of wearing bite-aligning mouthguards on muscle strength, power, agility and quickness in athletes. A search of the current literature was performed using the electronic databases (until 1 May 2021) Web of Science, Scopus and Medline. The inclusion criteria were: (1) descriptive design studies; (2) with randomized clinical trials; (3) examining the within-subject acute effects of wearing mouthguards on functional and neuromuscular performance parameters; (4) in physical active, recreational or high-standard athletes. Twenty-seven studies met the inclusion criteria. Sixteen reported positive effects in some of the variables assessed, two reported negative effects and the rest found no significant differences. Overall, the main findings described in the literature are inconclusive concerning the neuromuscular advantages of using mouthguards in muscle strength, power, agility and quickness. These discrepancies might be related to several factors such as differences in testing protocols, poor control of the jaw magnitude and improper mouthguard designs. Despite these differences, after conducting the present systematic review, the authors speculate that jaw clenching while wearing custom-made, bite-aligning oral devices might promote beneficial effects in lower limb power actions, especially in jump ability and knee extension movements. Thus, athletes might consider the use of mouthguards, not only for their protective role but also for the potential ergogenic effects in specific actions, mainly those for which lower limb muscular power are required.

26 December 2022 in Journal of Exercise Science & Fitness
Verified
Journal Article
Open access
AAAdrià Miró Alba
Adrià Miró Alba
Bernat BuscàBernat Buscà
Bernat Buscà
Jordi Arboix-AlióJordi Arboix-Alió
Jordi Arboix-Alió
PEPol Huertas Esquerrà
Pol Huertas Esquerrà
Joan Aguilera-CastellsJoan Aguilera-Castells
Joan Aguilera-Castells
The possible mechanisms supporting the relationship between the masticatory and the musculoskeletal systems have been recently investigated. It has been suggested that jaw clenching promotes ergogenic effects on prime movers through the phenomenon of concurrent activation potentiation (CAP). The purpose of this study was to analyse the effects of jaw clenching and jaw clenching while wearing mouthguard (MG) on muscle activity and force output during three upper body isometric strength tests. Twelve highly trained rink-hockey athletes were recruited for the study. A randomized, repeated measures within study design was carried out to compare the acute effects of three experimental conditions: jaw clenching while wearing MG (MG), jaw clenching without MG (JAW) and non-jaw clenching (NON-JAW). Statistical analyses revealed significant higher force output (p < 0.05) in all tests for MG conditions with respect to NON-JAW. When comparing JAW and NON-JAW conditions an increased peak force was found in handgrip (p = 0.045, d = 0.26) and bench press (p = 0.018, d = 0.43) but not in biceps curl (p = 0.562, d = 0.13). When comparing MG and JAW conditions, no differences were observed in any force output. In terms of muscle activity, significant differences were found in the agonist muscles of the handgrip test for MG with respect to NON-JAW (p = 0.031-0.046, d = 0.25-1.1). This study demonstrated that jaw clenching, with and without MG, may be a good strategy to elicit the CAP phenomenon, which seems to promote ergogenic effects in upper body isometric force production. The non-significant differences observed between JAW and MG suggested that the use of MG doesn't make a difference in enhancing the isometric force production neither the muscle activity in upper body isometric strength.

Bernat BuscàBernat Buscà
Bernat Buscà
Joan Aguilera-CastellsJoan Aguilera-Castells
Joan Aguilera-Castells
Jordi Arboix-AlióJordi Arboix-Alió
Jordi Arboix-Alió
AAAdrià Miró Alba
Adrià Miró Alba
AFAzahara Fort-Vanmeerhaeghe
Azahara Fort-Vanmeerhaeghe
Javier PeñaJavier Peña
Javier Peña
This study aimed to understand the acute responses on the muscular activity of primary movers during the execution of a half-squat under different unstable devices. Fourteen male and female high-standard track and field athletes were voluntarily recruited. A repeated measures design was used to establish the differences between muscle activity of the primary movers, the body centre of mass acceleration and the OMNI-Perceived Exertion Scale for Resistance Exercise (OMNI-Res) in a half-squat under four different stability conditions (floor, foam, BOSU-up and BOSU-down). A significant correlation was found between the highest performance limb muscle activity and body centre of mass acceleration for half-squat floor (r = 0.446, p = 0.003), foam (r = 0.322, p = 0.038), BOSU-up (r = 0.500, p = 0.001), and BOSU-down (r = 0.495, p = 0.001) exercises. For the exercise condition, the half-squat BOSU-up and BOSU-down significantly increased the muscle activity compared to half-squat floor (vastus medialis: p = 0.020, d = 0.56; vastus lateralis: p = 0.006, d = 0.75; biceps femoris: p = 0.000–0.006, d = 1.23–1.00) and half-squat foam (vastus medialis: p = 0.005–0.006, d = 0.60–1.00; vastus lateralis: p = 0.014, d = 0.67; biceps femoris: p = 0.002, d = 1.00) activities. This study contributes to improving the understanding of instability training, providing data about the acute muscular responses that an athlete experiences under varied stability conditions. The perturbation offered by the two BOSU conditions was revealed as the most demanding for the sample of athletes, followed by foam and floor executions.

8 January 2024 in Sports
Verified
Journal Article
Open access
PDF file
Jordi Arboix-AlióJordi Arboix-Alió
Jordi Arboix-Alió
Bernat BuscàBernat Buscà
Bernat Buscà
AAAdrià Miró Alba
Adrià Miró Alba
Chris BishopChris Bishop
Chris Bishop
AFAzahara Fort-Vanmeerhaeghe
Azahara Fort-Vanmeerhaeghe
The magnitude and direction of inter-limb asymmetries in a change of direction (COD) have increased interest in scientific research in recent years. This present study aimed to investigate the magnitude of asymmetries in an elite youth female basketball sample (n = 18, age = 17.79 ± 0.67 y) and determine its directionality using force platform technology. Participants performed 70° and 180° COD tests analyzing the following variables: time, ground contact time (GCT) and ground reaction forces (GRF) along the anterior–posterior, mediolateral, and vertical axes. Inter-limb asymmetries were evident in both COD tests, with substantial differences observed between limbs (p < 0.01). The asymmetry values ranged from 3.02% to 24.31% in COD 180° and from 1.99% to 21.70% in COD 70°, with anterior–posterior GRF consistently exhibiting the highest asymmetry magnitude. Additionally, the directionality exhibited variability between the tests, indicating poor agreement and suggesting the independent directionality of asymmetries across tasks. Moreover, players required more time to complete the COD 180°, the GCT was noticeably longer for the COD 180° than for the COD 70°, and GRF varied across the axis, suggesting that players adapt uniquely to the specific demands of each task. The utilization of force platforms presents a comprehensive approach to assess asymmetries and COD variables performance variables which are “angle-dependent”, which could have important implications for COD screening and effective training interventions.

6 February 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PEPol Huertas Esquerrà
Pol Huertas Esquerrà
Bernat BuscàBernat Buscà
Bernat Buscà
Jordi Arboix-AlióJordi Arboix-Alió
Jordi Arboix-Alió
AAAdrià Miró Alba
Adrià Miró Alba
LELaia H. Esquerrà
Laia H. Esquerrà
Joan Aguilera-CastellsJoan Aguilera-Castells
Joan Aguilera-Castells
Training using instability devices is common; however, for highly trained athletes, a single device may not provide sufficient challenge. This study examines the effect of superimposed vibration in suspended kneeling rollout. Seventeen physically active participants performed the exercise with non-vibration, vibration at 25 Hz, and vibration at 40 Hz. Muscle activation of the pectoralis clavicularis, pectoralis sternalis, anterior deltoid, serratus anterior, infraspinatus, and latissimus dorsi was recorded during exercise, and the perception of effort was recorded after exercise (OMNI-Res scale). One-way repeated-measures analysis of variance (ANOVA) showed significant differences for the kneeling rollout (p < 0.05). Friedman’s test showed significant differences in the OMNI-Res (p = 0.003). Pairwise comparison showed significant differences in the anterior deltoid (p = 0.004), latissimus dorsi (p < 0.001), infraspinatus (p = 0.001), and global activity (p < 0.001) between the 25 Hz and non-vibration conditions. It also showed significant differences between the 40 Hz and non-vibration conditions for pectoralis sternalis (p = 0.021), anterior deltoid (p = 0.005), latissimus dorsi (p < 0.001), infraspinatus (p = 0.027), and global activity (p < 0.001). The post hoc Conover pairwise comparison showed significant differences in the OMNI-Res only between the non-vibration and vibration at 40 Hz conditions (p = 0.011). Superimposed vibration increases the muscle activation of the upper limbs when performing the suspended kneeling rollout.