The objective of this study was to determine whether the addition of microsilver or nanosilver particles to an orthodontic primer affects shear bond strength (SBS) and bracket/adhesive failure. Bovine incisors were randomly divided into six groups with 16 specimens in each: In group 1 (control), brackets were bonded with Transbond™ XT primer. In the experimental groups, microsilver (groups 2 and 3) and nanosilver (groups 4–6) particles of different sizes were added to Transbond XT primer and light cured for 15 seconds [group 2: 0.1% (w/w) microsilver particle size 3.5–18 μm; group 3: 0.3% (w/w) microsilver particle size 3.5–18 μm; group 4: 0.11% (w/w) nanosilver particle size 12.6–18.5 nm; group 5: 0.18% (w/w) nanosilver particle size 12.6–18.5 nm; group 6: 0.33% (w/w) nanosilver particle size 12.6–18.5 nm]. Thereafter, brackets were bonded by light curing the adhesive for 20 seconds. After 24 hours of storage in distilled water at 37°C, SBS was measured with a Zwicki 1120 testing machine. The adhesive remnant index and the prevalence of silver spots on the specimen surface were determined under 10× magnification. Statistical two-way analysis of variance was performed to compare SBS, and a chi-square test was used to compare ARI scores and the prevalence of silver spots. No significant differences in SBS (control: 16.59 ± 6.82 MPa; group 2: 20.6 ± 4.19 MPa; group 3: 16.98 ± 4.84 MPa; group 4: 17.15 ± 5.92 MPa; group 5: 20.09 ± 3.35 MPa; group 6: 16.44 ± 4.51 MPa; p > 0.665) and ARI scores (p = 0.901) were found between the control group and any experimental group. Only experimental groups with nanosilver particles revealed statistically more silver spots on the remaining adhesive. Addition of small concentrations of microsilver or nanosilver particles affects neither SBS nor ARI scores. Addition of nanosilver particles results in silver spots in the remaining primer visible under 10× magnification. Further studies are needed to investigate the anti-caries potential and clinical performance of conventional orthodontic primer with incorporated nanosilver or microsilver particles.
Objectives: To investigate in vitro post-fatigue fracture behavior of endodontically treated molars having been differently restored. Methods: A total of 120 extracted human molars were used. A total of 120 specimens in 14 test groups and one control group (n = 8) were root canal treated. After postendodontic sealing and build-up (AdheSE Universal, SDR), additional MOD preparations were cut. Postendodontic restorations were: Direct restorations (Tetric EvoCeram BulkFill bonded with AdheSE Universal and EverX Posterior/Essentia bonded with G-Premio Bond; as filling (F) or direct partial crown (DPC) after reducing the cusps 2 mm; indirect adhesive restorations (partial crown/PC vs. full crown/FC): e.max CAD, Celtra Duo, both luted with Variolink Esthetic; indirect zirconia restorations (partial crown/PC vs. full crown/FC), luted with RelyX Unicem 2; indirect non-bonded cast gold restorations (partial crown/PC vs. full crown/FC; Degunorm), luted with Ketac Cem. Before and after 300,000 thermocycles (5/55 °C) and 1.2 Mio. A total of 100 N load cycles, replicas were analyzed under a SEM for marginal quality in enamel and dentin (where applicable) and finally, specimens were loaded until fracture. Results: In direct groups, there was no difference between RC and FRC in fracture strength (p > 0.05); however, direct partial crowns showed higher post-fatigue fracture resistance. Regarding marginal quality, intracoronal FRC restorations exhibited more gap-free margins in enamel than RC. In the indirect groups, there was no significant difference between partial and full crowns in any of the adhesively luted ceramic groups regarding post-fatigue fracture resistance. Zirconia partial crowns exhibited significantly lower marginal quality in enamel. Indirect groups performed significantly better than direct groups in fracture resistance. Within the indirect restorations, both cast gold groups and zirconia full crowns exhibited the highest fracture resistance being superior to control teeth. Significances: Within the limits of this in vitro investigation, it can be concluded that any kind of indirect restoration with cusp replacement is suitable for ETT restoration when a certain cavity extension is exceeded. All indirect restorations, i.e., endocrowns, partial crowns, and full crowns showed a promising performance after in vitro fatigue-loading.
Die Instrumentierung von Wurzelkanälen war bis in die 1990er-Jahre ausschließlich mit Stahlinstrumenten möglich [1]. Dazu wurden lange Zeit Handinstrumente eingesetzt, jedoch ist ihre Anwendung mit einem großen Zeitaufwand verbunden [2]. Zudem führt der Einsatz klassischer Stahlinstrumente, etwa K-Feilen oder K-Reamer, zu einer messbaren Verlagerung des Kanalverlaufs bei der Instrumentierung gekrümmter Wurzelkanäle [3], [4]. Ein Ansatz war hier die Entwicklung spezieller Techniken, wie etwa der im Jahre 1985 von Roane et al. [5] vorgestellten Balanced-Force-Technik, die durch Stahlinstrumente mit nicht schneidender Spitze eine deutliche Reduktion der Kanalverlagerung bewirkte. Diese zugleich flexibleren Stahlinstrumente führten zu einer wesentlich besseren Einhaltung des ursprünglichen Wurzelkanalverlaufs [6]. Bereits früh war man an Alternativen interessiert, die dem Zahnarzt die manuelle Instrumentierung abnehmen sollten. Die Entwicklung maschineller Aufbereitungssysteme aus Stahl sollte die mühsame und zeitintensive manuelle Instrumentierung ersetzen, was jedoch aufgrund der Rigidität sowie dem reduzierten Rückstellverhalten von Instrumenten aus Chrom-Nickel-Stahl (CrNi) insbesondere in gekrümmten Wurzelkanälen nicht selten zu Instrumentenfrakturen führte. Trotz verschiedener Weiterentwicklungen der maschinellen Antriebssysteme mit teilweise sehr ausgeklügelten Bewegungsmustern stellte jedoch die Verkürzung der Arbeitslänge ein bleibendes Problem dar, das daraus resultierte, dass die durch die maschinellen Antriebssysteme generierte Auf- und Abbewegung der maschinellen Stahlinstrumente zu einer Verblockung des apikalen Wurzelkanalabschnitts mit Dentinspänen führte [7]. Insofern waren Handinstrumente, nicht zuletzt auch aufgrund der guten Taktilität, lange Zeit Standard in der Wurzelkanalaufbereitung. Das änderte sich mit der Einführung von Nickel-Titan (NiTi) als Werkstoff zur Herstellung von Wurzelkanalinstrumenten, mit denen erstmals auch die vollrotierende Instrumentierung gekrümmter Wurzelkanäle möglich wurde. Die mühsame und zeitintensive manuelle Aufbereitung wurde durch die Einführung von maschinellen Instrumentensystemen deutlich vereinfacht. In den zurückliegenden 20 Jahren kamen zahlreiche vollrotierende NiTi-Systeme verschiedener Hersteller auf den Markt, die insbesondere hinsichtlich der Kriterien Aufbereitungsqualität und Arbeitssicherheit weitere Verbesserungen zeigten. Gemeinsames Merkmal aller klassischer NiTi-Instrumentensysteme war jedoch, dass sie eine nicht unerhebliche Instrumentenzahl erforderten, um eine sichere Instrumentierung des Wurzelkanals zu ermöglichen. Dies verursachte nicht nur eine lange Instrumentierungsdauer, die durch die Instrumentenwechsel noch erhöht wurde, sondern war auch mit erheblichen Kosten verbunden. Ein kurzer Überblick über die verschiedenen NiTi-Systeme soll die Unterschiede gegenüber den aktuellsten Entwicklungen von NiTi-Systemen aufzeigen, die insbesondere durch die Erhöhung der Schneideffizienz sowie durch Modifikationen von Feilensequenz und Feilenbewegung eine Reduktion der für die Wurzelkanalaufbereitung erforderlichen Instrumentenzahl ermöglichen.