YONG UN NA

Mr. YONG UN NA


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2023 in Fire
Verified
Journal Article
Open access
PDF file
YNYONG UN NA
YONG UN NA
JJJae-Wook Jeon
Jae-Wook Jeon
Unlike traditional coal-powered energy generation, renewable energy sources do not generate carbon dioxide emissions. To enhance the efficiency of renewable energy systems, energy storage systems (ESSs) have been implemented. However, in South Korea, ESS fire incidents have emerged as a significant social problem. Consequently, a government-formed committee was established to investigate the cause of these fires through the analysis of the data collected from ESSs, stored in the battery management system (BMS) log data of the fire-resistant safe storage. In the first phase of the investigation, the committee was unable to identify the underlying characteristic of ESS fires. Nevertheless, in the second phase, the investigation committee could identify the key characteristics of ESS fires by analyzing the BMS log data. ESS fires were found to occur when the state of charge level was more than 95% and during the initiation of thermal runaway in specific cells. Despite these findings, the committee was unable to determine the root cause of ESS fires.

28 October 2025 in Batteries
Verified
Journal Article
Open access
PDF file
SKSojin Kim
Sojin Kim
YYYeong-Seok Yu
Yeong-Seok Yu
CJChan-Seok Jeong
Chan-Seok Jeong
SLSang-Bum Lee
Sang-Bum Lee
YNYONG UN NA
YONG UN NA
The widespread adoption of lithium-ion batteries (LIBs) in electric vehicles (EVs) and energy-storage systems (ESSs) has raised growing concern about fire hazards caused by thermal runaway (TR). While many studies have examined cell-level TR mechanisms, investigations at the module level remain limited despite their importance for safety design. In this study, TR propagation was experimentally analyzed in a 12-cell (2p6s) pouch-type LIB module with EV-grade cells. The state of charge (SOC) and initiation location were the main variables. TR was initiated by a surface-mounted Kapton heating film, with power increased stepwise from 63 W to 141 W at 5-min intervals. Temperature, voltage, and heat release rate (HRR) were continuously monitored. Results showed that higher SOC led to earlier TR onset, shorter vent-to-ignition delay, and stronger combustion with jet flames. Center initiation produced rapid bidirectional propagation with a peak heat release rate (PHRR) of 590 kW and a propagation time of 107 s, whereas edge initiation caused slower unidirectional spread with a PHRR of 105 kW and a propagation time of 338 s. These results demonstrate that both SOC and initiation location critically control TR severity and propagation, providing essential data for EV fire safety evaluation and module design.

22 August 2024 in IEEE Access
Verified
Journal Article
Open access
YNYONG UN NA
YONG UN NA
JJJae Wook Jeon
Jae Wook Jeon
Lithium-ion batteries, known for their superior efficiency among secondary batteries, have found widespread application across various fields, including small home appliances, mobile device, electric vehicles, and energy storage systems (ESS). However, despite their numerous advantages, the propensity for lithium-ion batteries to catch fire poses a significant challenge to their broader adoption. To address this issue, investigations into battery fires aim to identify the underlying causes; however, the inherent characteristics of lithium-ion batteries, particularly thermal runaway, limit the effectiveness of these investigations. This study examines three potential scenarios (electrical, mechanical, thermal) that could lead to thermal runaway in lithium-ion batteries. And for systematic research, the study specifically selected overcharging and over-discharging to represent electrical abuse. To simulate mechanical abuse, penetration was employed as a method to ensure that thermal runaway would not prematurely cease during the experiments. In the case of thermal abuse, tests were conducted under varying charging rates. When analyzing the size and distribution of voids along the Y-axis and Z-axis, thermal abuse was clearly distinguishable. However, accurately differentiating between mechanical abuse and electrical abuse presented a challenge. Consequently, by analyzing the tendency of voids from outer to the inner regions of the battery, it became possible to distinguish between mechanical and electrical abuse. Additionally, the study’s reliability was enhanced by confirming that the fire cases generated by actual electrical abuse exhibited a similar tendency when compared with the void data obtained during the study for electrical abuse.

1 January 2026 in International Journal of Energy Research
Verified
Journal Article
Open access
YNYONG UN NA
YONG UN NA
Jonghoon KimJonghoon Kim
Jonghoon Kim
This study investigates the fire hazards of lithium‐ion battery (LIB) products that rely solely on a protection circuit module (PCM) instead of the battery management system (BMS). Although PCMs can provide basic overcharge and overdischarge cut‐off functions, their voltage‐based control is insufficient to ensure battery safety under severe operating conditions. To evaluate these limitations, repeated charge/discharge experiments were conducted using a commercial cylindrical 18,650 LIB cell coupled with a PCM under extreme temperature environments (40 and −20°C), and sequential mixed‐temperature conditions. Electrochemical impedance spectroscopy (EIS) analysis revealed that loss of lithium inventory (LLI) was the dominant degradation mechanism in all cases, while computed tomography (CT) analysis confirmed internal structural deformation caused by pressure buildup during cycling. In particular, the low‐temperature condition produced more severe electrochemical degradation and mechanical damage than the high‐temperature condition, leading to earlier failure. In addition, MATLAB‐based state‐of‐health (SOH) analysis and comparison with a normal cell simulation showed that extreme temperature cycling drastically accelerated degradation; the 80% SOH level was reached after about 25 cycles at 40°C and 15 cycles at −20°C, compared with about 400 cycles under normal conditions. These results demonstrate that PCM‐only battery systems are highly vulnerable to hazardous degradation under harsh environments, especially at low temperatures, and indicate the need for strengthened certification standards and safety regulations for small consumer products using LIBs.