Rezvan Nasiri

Dr. Rezvan Nasiri

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
RNRezvan Nasiri
Rezvan Nasiri
AAArjang Ahmadi
Arjang Ahmadi
MAMajid Nili Ahmadabadi
Majid Nili Ahmadabadi
In this paper, we present a new perspective to design an unpowered exoskeleton for metabolic rate reduction in running. According to our studies on human biomechanics, it was observed that having a torsional spring that applies torque as a linear function of the difference between two hips angles ( ${d}$ -angle), compared with a local spring which applies torque as a function of hip angle ( ${h}$ -angle), provides a better condition for hip moment compensation and, consequently, metabolic rate reduction. Accordingly, a new type of unpowered exoskeleton device for realization of this idea was designed, and a prototype of this exoskeleton was constructed. This exoskeleton was tested on 10 healthy active subjects for running at 2.5 m s −1 . In this experiment, 8.0 ± 1.5% (mean ± s.e.m.) metabolic rate reduction (compared with the no-exoskeleton case) was achieved.

27 September 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
MSMohammad Shushtari
Mohammad Shushtari
RNRezvan Nasiri
Rezvan Nasiri
Arash AramiArash Arami
Arash Arami
This letter presents a novel method for reference trajectory adaptation in lower limb rehabilitation exoskeletons during walking. Our adaptation rule is extracted from a cost function that penalizes both interaction force and trajectory modification. By adding trajectory modification term into the cost function, we restrict the boundaries of the reference trajectory adaptation according to the patient's motor capacity. The performance of the proposed adaptation method is studied analytically in terms of convergence and optimality. We also developed a realistic dynamic walking simulator and utilized it to analyze our method. The proposed trajectory adaptation technique guarantees convergence to a stable, reliable, and rhythmic reference trajectory with no prior knowledge about the human intended motion. Our simulations demonstrate the convergence of exoskeleton trajectories to those of simulated healthy subjects while the exoskeleton trajectories adapt less to the trajectories of patients with reduced motor capacity (less reliable trajectories). Furthermore, the gait stability and spatiotemporal parameters such as step time symmetry and minimum toe clearance were enhanced by the adaptation in all subjects. Our mathematical analysis and simulation results show the applicability and effectiveness of the proposed method and its potential to be used in lower limb rehabilitation exoskeletons.

4 June 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HAHamidreza Aftabi
Hamidreza Aftabi
RNRezvan Nasiri
Rezvan Nasiri
MAMajid Nili Ahmadabadi
Majid Nili Ahmadabadi
Due to the complexity and high degrees of freedom, the detailed assessment of human biomechanics is necessary for the design and optimization of an effective exoskeleton. In this paper, we present full kinematics, dynamics, and biomechanics assessment of unpowered exoskeleton augmentation for human running gait. To do so, the considered case study is the assistive torque profile of I-RUN. Our approach is using some extensive data-driven OpenSim simulation results employing a generic lower limb model with 92-muscles and 29-DOF. In the simulation, it is observed that exoskeleton augmentation leads to $$4.62\%$$ 4.62 % metabolic rate reduction for the stiffness coefficient of $$\alpha ^*=0.6$$ α ∗ = 0.6 . Moreover, this optimum stiffness coefficient minimizes the biological hip moment by $$26\%$$ 26 % . The optimum stiffness coefficient ( $$\alpha ^*=0.6$$ α ∗ = 0.6 ) also reduces the average force of four major hip muscles, i.e., Psoas, Gluteus Maximus, Rectus Femoris, and Semimembranosus. The effect of assistive torque profile on the muscles’ fatigue is also studied. Interestingly, it is observed that at $$\alpha ^{\#}=0.8$$ α # = 0.8 , both all 92 lower limb muscles’ fatigue and two hip major mono-articular muscles’ fatigue have the maximum reduction. This result re-confirm our hypothesis that ”reducing the forces of two antagonistic mono-articular muscles is sufficient for involved muscles’ total fatigue reduction.” Finally, the relation between the amount of metabolic rate reduction and kinematics of hip joint is examined carefully where for the first time, we present a reliable kinematic index for prediction of the metabolic rate reduction by I-RUN augmentation. This index not only explains individual differences in metabolic rate reduction but also provides a quantitative measure for training the subjects to maximize their benefits from I-RUN.

8 December 2016 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
RNRezvan Nasiri
Rezvan Nasiri
MKMahdi Khoramshahi
Mahdi Khoramshahi
MSMohammad Shushtari
Mohammad Shushtari
MAMajid Nili Ahmadabadi
Majid Nili Ahmadabadi
We present a compliance adaptation method for online natural dynamics modification of multijoint robots performing cyclic tasks. In this method, parameters of multibasis nonlinear compliances acting in parallel with actuators are adapted to minimize actuation forces that results in joint-by-joint energy consumption reduction. Stability, convergence, and optimality of this method are proved analytically for a general compliance structure. We do not impose any specific constraint on the controller structure and tracking performance, yet stable tracking of cyclic motions is necessary for the convergence to the optimal solution. Extensive simulations on a set of systems ranging from simple mass-spring system to robotic manipulator (with linear and nonlinear compliances), along with the experimental results on a 1-degree of freedom compliant revolute joint with two basis functions in the compliance profile, demonstrate the efficiency of our method in terms of stability, convergence, and optimality; i.e., actuation force and energy consumption reduction.

24 July 2021 in Robotics
Verified
Journal Article
Open access
PDF file
RNRezvan Nasiri
Rezvan Nasiri
MSMohammad Shushtari
Mohammad Shushtari
Arash AramiArash Arami
Arash Arami
In this paper, we present a novel adaptation rule to optimize the exoskeleton assistance in rehabilitation tasks. The proposed method adapts the exoskeleton contribution to user impairment severity without any prior knowledge about the user motor capacity. The proposed controller is a combination of an adaptive feedforward controller and a low gain adaptive PD controller. The PD controller guarantees the stability of the human-exoskeleton system during feedforward torque adaptation by utilizing only the human-exoskeleton joint positions as the sensory feedback for assistive torque optimization. In addition to providing a convergence proof, in order to study the performance of our method we applied it to a simplified 2-DOF model of human-arm and a generic 9-DOF model of lower limb to perform walking. In each simulated task, we implemented the impaired human torque to be insufficient for the task completion. Moreover, the scenarios that violate our convergence proof assumptions are considered. The simulation results show a converging behavior for the proposed controller; the maximum convergence time of 20 s is observed. In addition, a stable control performance that optimally supplements the remaining user motor contribution is observed; the joint angle tracking error in steady condition and its improvement compared to the start of adaptation are as follows: shoulder 0.96±2.53° (76%); elbow −0.35±0.81° (33%); hip 0.10±0.86° (38%); knee −0.19±0.67° (25%); and ankle −0.05±0.20° (60%). The presented simulation results verify the robustness of proposed adaptive method in cases that differ from our mathematical assumptions and indicate its potentials to be used in practice.

1 November 2017 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
MKMahdi Khoramshahi
Mahdi Khoramshahi
RNRezvan Nasiri
Rezvan Nasiri
MSMohammad Shushtari
Mohammad Shushtari
AIAuke Jan Ijspeert
Auke Jan Ijspeert
MAMajid Nili Ahmadabadi
Majid Nili Ahmadabadi