Noboru Funakoshi

Dr. Noboru Funakoshi

Kyoto Shimogamo Hospital
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

10 November 2014 in Arthroscopy Techniques
Verified
Journal Article
Open access
DMDaisuke Mori
Daisuke Mori
NFNoboru Funakoshi
Noboru Funakoshi
FYFumiharu Yamashita
Fumiharu Yamashita
Delamination is a commonly observed finding at the time of rotator cuff repair, but few studies have described the surgical techniques used for delaminated rotator cuff tears (RCTs) or their clinical outcomes. We developed a technique using a combination of a double row and an additional row, which we call lamina‐specific double‐row fixation, for large delaminated RCTs. The lamina‐specific double‐row technique is performed using an additional row (lamina‐specific lateral row) of suture anchors placed between the typical medial and lateral rows of suture anchors. The technique is performed as follows: (1) medial‐row sutures are passed through the inferior (articular‐side) and superior (bursal‐side) layers in a mattress fashion; (2) lamina‐specific lateral‐row simple sutures are passed through the inferior layer; and (3) lateral‐row simple sutures are passed through the superior layer. We believe that this technique offers the following advantages: (1) creation of a larger area of contact between the inferior layer and the footprint, (2) higher initial fixation strength of the articular‐side components of the repaired rotator cuff tendon, and (3) an adaptation between the superficial and inferior layers. This technique represents an alternative option in the operative treatment of large delaminated RCTs. Technique Video: video See video under supplementary data.

1 October 2018 in International Journal of Rheumatic Diseases
Verified
Journal Article
Closed access
PDF file
KKKazuha Kizaki
Kazuha Kizaki
FYFumiharu Yamashita
Fumiharu Yamashita
THTomoya Hayashi
Tomoya Hayashi
NFNoboru Funakoshi
Noboru Funakoshi

31 May 2021 in Biomimetics
Verified
Journal Article
Open access
PDF file
THTakehito Hananouchi
Takehito Hananouchi
SUSoshi Uchida
Soshi Uchida
YHYusuke Hashimoto
Yusuke Hashimoto
NFNoboru Funakoshi
Noboru Funakoshi
SAStephen K. Aoki
Stephen K. Aoki
Cadaver tissue has been identified as the highest-fidelity anatomical representation in terms of the training for orthopedic surgery, including for arthroscopy of a damaged hip labrum. However, hip labrum stiffness in vivo and in cadavers has not been directly compared. The purpose of this study was to compare in vivo and cadaveric hip labrum stiffness during pull-probing with a force sensor. We measured the resistance force of the hip labrum in ten patients during hip arthroscopy (i.e., in vivo) and compared it with ten cadavers, both intact and detached from the acetabulum, using a surgical knife. We confirmed a partial labral tear (i.e., not detached fully from the rim) at an antero-superior potion in all of the patients. The mean highest resistance levels for the hip labrum in the patients (4.7 N) were significantly lower than the intact cadaveric labrum (8.3 N), and slightly higher than the detached labrum (4.2 N). In this study, the stiffness of the cadaveric labrum tissue was similar to that of the in-vivo hip labrum.

1 March 2018 in Knee Surgery & Related Research
Verified
Journal Article
Open access
PDF file
KKKazuha Kizaki
Kazuha Kizaki
FYFumiharu Yamashita
Fumiharu Yamashita
NFNoboru Funakoshi
Noboru Funakoshi
Stress fractures of the patella occurring in athletes are quite rare and only 23 cases have been introduced in English literatures. Stress fractures of the patella are classified into two types: transverse and longitudinal. They are mostly seen in the distal one-third of the patella on a plain lateral radiograph. We present here a 16-year-old female basketball player with a stress fracture of the patella. Her serial radiographs demonstrated progression of the fracture including a lytic cortex lesion, known as the gray cortex sign for early stage stress fractures, in the distal one-third of the patella on plain lateral radiographs. In addition, we introduce a surgical technique using non-absorbable suture ligatures (No.2 Ethibond) for a displaced transverse stress fracture of the patella when the extensor mechanism is intact. The ligatures are passed through into the patella using suture passers and simply tied down over the top of the patella. In our case, it led to neither hardware-related nor circumferential loop-related irritation postoperatively.

7 December 2017 in Arthroplasty Today
Verified
Journal Article
Open access
PDF file
KKKazuha Kizaki
Kazuha Kizaki
FYFumiharu Yamashita
Fumiharu Yamashita
NFNoboru Funakoshi
Noboru Funakoshi
SUSoshi Uchida
Soshi Uchida
The possible increased risk of dislocation with a posterior approach for femoral hemiarthroplasty is attributed to disruption of the posterior soft-tissue structures, including the posterior capsular ligament structure and short external rotators of the hip. In this surgical technical note, we demonstrate the surgical technique for shoelace suturing of the external rotators and the capsule with use of ULTRATAPE. After prosthesis stem insertion, shoelace suturing using ULTRATAPE was performed between the great trochanter and the external rotators for preventing the external rotators from tearing. Also, ULTRATAPE was sewed alternately on the split capsule like shoe lacing, and it was laced up from proximal to distal in line with the split as shoelaces tied down. The shoelace suturing technique using ULTRATAPE after a posterior approach to the hip joint, possibly lowers risks of tearing hip capsular ligament and external rotators and stabilizes the posterior wall.