Maria Vinas-Pena

Dr. Maria Vinas-Pena

CSIC—Instituto de Óptica Daza de Valdés, (IO-CSIC), Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
MVMaria Vinas-Pena
Maria Vinas-Pena
CDCarlos Dorronsoro
Carlos Dorronsoro
DCDaniel Cortes
Daniel Cortes
DPDaniel Pascual
Daniel Pascual
SMSusana Marcos
Susana Marcos
Longitudinal Chromatic Aberration (LCA) influences the optical quality of the eye. However, the reported LCA varies across studies, likely associated to differences in the measurement techniques. We present LCA measured in subjects using wavefront sensing, double-pass retinal images, and psychophysical methods with a custom-developed polychromatic Adaptive Optics system in a wide spectral range (450-950 nm), with control of subjects’ natural aberrations. LCA measured psychophysically was significantly higher than that from reflectometric techniques (1.51 D vs 1.00 D in the 488-700 nm range). Ours results indicate that the presence of natural aberrations is not the cause for the discrepancies across techniques.

26 September 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MVMaria Vinas-Pena
Maria Vinas-Pena
SLSawides Lucie
Sawides Lucie
PGPablo De Gracia
Pablo De Gracia
SMSusana Marcos
Susana Marcos
The visual system adjusts to changes in the environment, as well as to changes within the observer, adapting continuously to maintain a match between visual coding and visual environment. We evaluated whether the perception of oriented blur is biased by the native astigmatism, and studied the time course of the after-effects following spectacle correction of astigmatism in habitually non-corrected astigmats. We tested potential shifts of the perceptual judgments of blur orientation in 21 subjects. The psychophysical test consisted on a single interval orientation identification task in order to measure the perceived isotropic point (astigmatism level for which the image did not appear oriented to the subject) from images artificially blurred with constant blur strength (B = 1.5 D), while modifying the orientation of the blur according to the axis of natural astigmatism of the subjects. Measurements were performed after neutral (gray field) adaptation on naked eyes under full correction of low and high order aberrations. Longitudinal measurements (up to 6 months) were performed in three groups of subjects: non-astigmats and corrected and uncorrected astigmats. Uncorrected astigmats were provided with proper astigmatic correction immediately after the first session. Non-astigmats did not show significant bias in their perceived neutral point, while in astigmatic subjects the perceived neutral point was significantly biased, typically towards their axis of natural astigmatism. Previously uncorrected astigmats shifted significantly their perceived neutral point towards more isotropic images shortly (2 hours) after astigmatic correction wear, and, once stabilized, remained constant after 6 months. The shift of the perceived neutral point after correction of astigmatism was highly correlated with the amount of natural astigmatism. Non-corrected astigmats appear to be naturally adapted to their astigmatism, and astigmatic correction significantly changes their perception of their neutral point, even after a brief period of adaptation.

7 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MVMaria Vinas-Pena
Maria Vinas-Pena
CBClara Benedi-Garcia
Clara Benedi-Garcia
SASara Aissati
Sara Aissati
DPDaniel Pascual
Daniel Pascual
VAVyas Akondi
Vyas Akondi
SMSusana Marcos
Susana Marcos
Adaptive optics (AO) visual simulators based on deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different multifocal lens designs. However, the correspondence of this simulation with that obtained through real intraocular lenses (IOLs) tested on the same eyes has not been, to our knowledge, demonstrated. We compare through-focus (TF) optical and visual quality produced by real multifocal IOLs (M-IOLs) -bifocal refractive and trifocal diffractive- projected on the subiect’s eye with those same designs simulated with a spatial light modulator (SLM) or an optotunable lens working in temporal multiplexing mode (SimVis technology). Measurements were performed on 7 cyclopleged subjects using a custom-made multichannel 3-active-optical-elements polychromatic AO Visual Simulator in monochromatic light. The same system was used to demonstrate performance of the real IOLs, SLM and SimVis technology simulations on bench using double-pass imaging on an artificial eye. Results show a general good correspondence between the TF performance with the real and simulated M-IOLs, both optically (on bench) and visually (measured visual acuity in patients). We demonstrate that visual simulations in an AO environment capture to a large extent the individual optical and visual performance obtained with real M-IOLs, both in absolute values and in the shape of through-focus curves.

1 December 2013 in Optometry and Vision Science
Verified
Journal Article
Closed access
MVMaria Vinas-Pena
Maria Vinas-Pena
PGPablo De Gracia
Pablo De Gracia
CDCarlos Dorronsoro
Carlos Dorronsoro
LSLucie Sawides
Lucie Sawides
GMGildas Marin
Gildas Marin
SMSusana Marcos
Susana Marcos

24 January 2019 in Optics Express
Verified
Journal Article
Open access
PDF file
CDCarlos Dorronsoro
Carlos Dorronsoro
XBXoana Barcala
Xoana Barcala
EGEnrique Gambra
Enrique Gambra
VAVyas Akondi
Vyas Akondi
LSLucie Sawides
Lucie Sawides
SMSusana Marcos
Susana Marcos
Tunable lenses are becoming ubiquitous, in applications including microscopy, optical coherence tomography, computer vision, quality control, and presbyopic corrections. Many applications require an accurate control of the optical power of the lens in response to a time-dependent input waveform. We present a fast focimeter (3.8 KHz) to characterize the dynamic response of tunable lenses, which was demonstrated on different lens models. We found that the temporal response is repetitive and linear, which allowed the development of a robust compensation strategy based on the optimization of the input wave, using a linear time-invariant model. To our knowledge, this work presents the first procedure for a direct characterization of the transient response of tunable lenses and for compensation of their temporal distortions, and broadens the potential of tunable lenses also in high-speed applications.

21 October 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
MVMaria Vinas-Pena
Maria Vinas-Pena
SASara Aissati
Sara Aissati
MRMercedes Romero
Mercedes Romero
CBClara Benedi-Garcia
Clara Benedi-Garcia
NGNuria Garzon
Nuria Garzon
SMSusana Marcos
Susana Marcos
While multifocal intraocular lenses (MIOLs) are increasingly implanted to correct for presbyopia, how one sees with a multifocal correction is hard to explain and imagine. The current study evaluates the quality of various visual simulating technologies by comparing vision with simulated MIOLs pre-operatively and the implanted MIOLs post-operatively in the same patients. Two simulation platforms were used: (1) a custom-developed adaptiveoptics (AO) system, with two visual simulator devices: a spatial light modulator (SLM) and an optotunable lens operating under temporal multiplexing (SimVis); and (2) a wearable, binocular, large field of view SimVis2Eyes clinical simulator (SimVis Gekko, 2Eyes Vision, Madrid, Spain). All devices were programmed to simulate a trifocal diffractive MIOL (POD F, FineVision, PhysIOL). Eight patients were measured pre-operatively simulating the trifocal lens and post-operatively with implantation of the same MIOL. Through-focus decimal visual acuity (TF VA) was measured (1) monocularly in monochromatic light using a four-alternative-forced-choice procedure in the AO system; and (2) binocularly using a clinical optotype in white light. Visual simulations pre-operatively predict well the TF VA performance found post-operatively in patients implanted with the real IOL. The average RMS difference between TF curves with the different visual simulators was 0.05 ± 0.01. The average RMS difference between the TF VA curves with the SimVis pre-operatively and the real MIOL post-operatively was 0.06 ± 0.01 in both platforms, and it was higher in cataract eyes (0.08 ± 0.01, on average across simulators) than in eyes with clear lens. In either group the shape of the TF curves is similar across simulators and pre- and post-operatively. TF curves cross-correlated significantly between simulators (lag k = 0, rho = 0.889), as well as with results with the real MIOL implanted (lag k = 0, rho = 0.853). Visual simulations are useful programmable tools to predict visual performance with MIOLs, both in an AO environment and in a clinical simulator. Pre-operative visual simulations and post-operative data are in good agreement.