Ratan Gupta

Ratan Gupta


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2021 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Closed access
PDF file
KDKeerti Kaumudee Dixit
Keerti Kaumudee Dixit
VRVenkatesh Ramesh
Venkatesh Ramesh
RGRatan Gupta
Ratan Gupta
NNNarendra Singh Negi
Narendra Singh Negi
RSRuchi Singh
Ruchi Singh
PSPoonam Salotra
Poonam Salotra
: Despite the dwindling number of visceral leishmaniasis (VL) cases in India, there is an urgent need for early and unequivocal diagnostics for controlling and preventing the reemergence of VL. Post–kala-azar dermal leishmaniasis (PKDL), a dermal sequela of VL, serves as a reservoir of the parasite. Diagnosis of PKDL, especially the macular variant, is challenging and poses impediment toward attainment of VL elimination. In this study, a real-time fluorimetry loop-mediated isothermal amplification (RealAmp) assay has been established for the detection of different clinical manifestations of leishmaniasis. The study included 150 leishmaniasis patients (25 VL, 25 cutaneous leishmaniasis [CL], and 100-PKDL) along with 120 controls. The assay demonstrated sensitivity of 100% (95% CI: 86.68–100) for diagnosis of VL and PKDL (95% CI: 79.61–100) and 96% (95% CI: 86.68–100) for CL with 100% specificity. Moreover, considering the cardinal role of PKDL, diagnosis using minimally invasive slit aspirate was explored, which demonstrated remarkable sensitivity of 96% (95% CI: 87.64–98.47). As a test of cure for PKDL, RealAmp successfully detected parasite in two of posttreatment cases who later reported relapse on follow-up. Also, direct sample lysis using slit aspirate was attempted in a small group that yielded sensitivity of 89% (95% CI: 67.20–96.90). RealAmp depicted excellent diagnostic accuracy in the diagnosis of leishmaniasis in concordance with the established SYBR Green I–based (Molecular Probes, Eugene, OR) visual loop-mediated isothermal amplification (LAMP) and the reference comparator real-time PCR. The study endorsed the employment of LAMP either as visual-LAMP or RealAmp for an accurate and expeditious diagnosis of PKDL and as a tool for assessment of cure.

16 September 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
MAMudsser Azam
Mudsser Azam
KUKirti Upmanyu
Kirti Upmanyu
RGRatan Gupta
Ratan Gupta
SSSruthy K S
Sruthy K S
MMMonika Matlani
Monika Matlani
RSRuchi Singh
Ruchi Singh
To strengthen malaria surveillance, field-appropriate diagnostics requiring limited technical resources are of critical significance. Loop-mediated isothermal amplification (LAMP) based malaria diagnostic assays are potential point-of-care tests with high sensitivity and specificity and have been used in low-resource settings. Plasmodium vivax–specific consensus repeat sequence (CRS)-based and Plasmodium falciparum–specific 18S rRNA primers were designed, and a two-tube LAMP assay was developed. The diagnostic performance of a closed-tube LAMP assay and Loopamp™ Malaria Detection (Pan/Pf, Pv) kit was investigated using nested PCR confirmed mono- and co-infections of P. vivax and P. falciparum positive (n = 149) and negative (n = 67) samples. The closed-tube Pv LAMP assay showed positive amplification in 40 min (limit of detection, LOD 0.7 parasites/µL) and Pf LAMP assay in 30 min (LOD 2 parasites/µL). Pv LAMP and Pf LAMP demonstrated a sensitivity and specificity of 100% (95% CI, 95.96–100% and 89.85–100%, respectively). The LoopampTM Pan/Pf Malaria Detection kit demonstrated a sensitivity and specificity of 100%, whereas LoopampTM Pv showed a sensitivity of 98.36% (95% CI, 91.28–99.71%) and specificity of 100% (95% CI, 87.54–100%). The developed two-tube LAMP assay is highly sensitive (LOD ≤ 2 parasite/µL), demonstrating comparable results with the commercial Loopamp™ Malaria Detection (Pf/pan) kit, and was superior in detecting the P. vivax co-infection that remained undetected by the Loopamp™ Pv kit. The developed indigenous two-tube Pf/Pv malaria detection can reliably be used for mass screening in resource-limited areas endemic for both P. falciparum and P. vivax malaria.

1 October 2013 in Journal of Clinical Neonatology
Verified
Journal Article
Open access
PDF file
AMAliza Mittal
Aliza Mittal
RGRatan Gupta
Ratan Gupta
SSShobha Sharma
Shobha Sharma
KAKailash Chandra Aggarwal
Kailash Chandra Aggarwal
Stress/sepsis induced transient hyperglycemia in the newborn may present with extremely high blood sugar values and may mimic neonatal diabetes mellitus. We present a case of neonatal septicemia with stress induced hyperglycemia mimicking neonatal diabetes mellitus. Extremely high blood sugar values upto 1529 mg/dl with metabolic acidosis were noted in a term good weight baby causing a diagnostic dilemma. It can be seen even in term babies, contrary to the belief that it occurs in preterm and small for gestation babies. Considering the prognostic implications it may cause it is important that hyperglycemia is promptly treated by insulin infusion.

4 September 2024 in Pathogens
Verified
Journal Article
Open access
PDF file
MAMudsser Azam
Mudsser Azam
SSSaurabh Singh
Saurabh Singh
RGRatan Gupta
Ratan Gupta
MMMayank Mayank
Mayank Mayank
SKsushruta Kathuria
sushruta Kathuria
RSRuchi Singh
Ruchi Singh
The accurate diagnosis and identification of Leishmania species are crucial for the therapeutic selection and effective treatment of leishmaniasis. This study aims to develop and evaluate the use of high-resolution melting curve analysis (HRM)-PCR for Leishmania species identification causing visceral leishmaniasis (VL), post-kala-azar dermal leishmaniasis (PKDL) and cutaneous leishmaniasis (CL) in the Indian subcontinent. Two multi-copy targets (ITS-1 and 7SL-RNA genes) were selected, and an HRM-PCR assay was established using L. donovani, L. major, and L. tropica standard strain DNA. The assay was applied on 93 clinical samples with confirmed Leishmania infection, including VL (n = 30), PKDL (n = 50), and CL (n = 13) cases. The ITS-1 HRM-PCR assay detected as little as 0.01 pg of template DNA for L. major and up to 0.1 pg for L. donovani and L. tropica. The detection limit for the 7SL-RNA HRM-PCR was 1 pg for L. major and 10 pg for L. donovani and L. tropica. The ITS-1 HRM-PCR identified 68 out of 93 (73.11%) leishmaniasis cases, whereas 7SL-RNA HRM-PCR could only detect 18 out of 93 (19.35%) cases. A significant correlation was observed between the kDNA-based low Ct values and ITS-1 HRM-PCR positivity in the VL (p = 0.007), PKDL (p = 0.0002), and CL (p = 0.03) samples. The ITS-1 HRM-PCR assay could identify Leishmania spp. causing different clinical forms of leishmaniasis in the Indian subcontinent, providing rapid and accurate results that can guide clinical management and treatment decisions.

28 March 2013 in Indian Pediatrics
Verified
Journal Article
Closed access
PDF file
RGRatan Gupta
Ratan Gupta
KSKumar Saurabh
Kumar Saurabh
SSShobha Sharma
Shobha Sharma
RGRiyanka Gupta
Riyanka Gupta

27 October 2020 in International Journal of Reproduction, Contraception, Obstetrics and Gynecology
Verified
Journal Article
Open access
PDF file
ADAkanksha Dwivedi
Akanksha Dwivedi
RGRatan Gupta
Ratan Gupta
KAKailash C. Agarwal
Kailash C. Agarwal
KRKumari U. Rani
Kumari U. Rani
Background: India has moved from single drug Antiretroviral Therapy (ART) in 2002 to triple drug ART in 2013 to prevent parent to child transmission of HIV. The aim of the study was to know the effects of triple drug ART on maternal CD4+ count and prevention of HIV transmission to baby along with its adherence, side effects and pregnancy outcome. Methods: A prospective study wsas done in Safdarjung Hospital, New Delhi on 40 HIV positive pregnant women who received single dose combination of triple drug ART. CD4+ count, LFT and KFT were done before beginning of ART and repeated after 6 months of ART. The infants received nevirapine prophylaxis and HIV status was determined by DBS PCR at 6 weeks. Results: The median CD4+ count was 317 and 397 pre and post ART for 6 months respectively (p value<0.001. Low birth weight (LBW) was seen in 43.59% which was statistically significant but confounded as 76.4% of these babies were preterm. 23.08% of babies had an APGAR of < 7 at 1 minute, out of which 77.7% were preterm. Nine out of 39 infants (one had abortion) needed NICU admission. Only one baby (2.56%) was HIV positive who died at 4 months of age due to pneumonia. There was no defaulter and no statistically significant changes in LFT and KFT after 6 months of ART. Conclusions: Triple drug ART offers greater convenience improves fetomaternal outcome and minimize the risk of HIV transmission from mother to child.