Alexander Kies

Dr. Alexander Kies

Frankfurt Institute for Advanced Studies, Goethe University Frankfurt, Ruth-Moufang-Str. 1, 60438 Frankfurt am Main, Germany

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2016 in Energies
Verified
Journal Article
Open access
PDF file
AKAlexander Kies
Alexander Kies
BSBruno Schyska
Bruno Schyska
LBLueder Von Bremen
Lueder Von Bremen
The capacity factor of a power plant is the ratio of generation over its potential generation. It is an important measure to describe wind and solar resources. However, the fluctuating nature of renewable power generation makes it difficult to integrate all generation at times. Whenever generation exceeds the load, curtailment or storage of energy is required. With increasing renewable shares in the power system, the level of curtailment will further increase. In this work, the influence of the curtailment on the capacity factors for a highly renewable German power system is studied. An effective capacity factor is introduced, and the implications for the distribution of renewable power plants are discussed. Three years of highly-resolved weather data were used to model wind and solar power generation. Together with historical load data and a transmission model, a possible future German power system was simulated. It is shown that effective capacity factors for unlimited transmission are strongly reduced by up to 60% (wind) and 70% (photovoltaics) and therefore of limited value in a highly renewable power system. Furthermore, the results demonstrate that wind power benefits more strongly from a reinforced transmission grid than photovoltaics (PV) does.

15 November 2016 in Energies
Verified
Journal Article
Open access
PDF file
AKAlexander Kies
Alexander Kies
BSBruno Schyska
Bruno Schyska
LBLueder Von Bremen
Lueder Von Bremen
Shares of renewables continue to grow in the European power system. A fully renewable European power system will primarily depend on the renewable power sources of wind and photovoltaics (PV), which are not dispatchable but intermittent and therefore pose a challenge to the balancing of the power system. To overcome this issue, several solutions have been proposed and investigated in the past, including storage, backup power, reinforcement of the transmission grid, and demand side management (DSM). In this paper, we investigate the potential of DSM to balance a simplified, fully renewable European power system. For this purpose, we use ten years of weather and historical load data, a power-flow model and the implementation of demand side management as a storage equivalent, to investigate the impact of DSM on the need for backup energy. We show that DSM has the potential to reduce the need for backup energy in Europe by up to one third and can cover the need for backup up to a renewable share of 67%. Finally, it is demonstrated that the optimal mix of wind and PV is shifted by the utilisation of DSM towards a higher share of PV, from 19% to 36%.

1 December 2021 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
AKAlexander Kies
Alexander Kies
BSBruno U. Schyska
Bruno U. Schyska
MBMariia Bilousova
Mariia Bilousova
OSOmar El Sayed
Omar El Sayed
Jakub JuraszJakub Jurasz
Jakub Jurasz
HSHorst Stoecker
Horst Stoecker

2 February 2022 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
Jakub JuraszJakub Jurasz
Jakub Jurasz
MGMohammed Guezgouz
Mohammed Guezgouz
PCPietro E. Campana
Pietro E. Campana
AKAlexander Kies
Alexander Kies

17 July 2019 in SN Applied Sciences
Verified
Journal Article
Open access
PDF file
APAdam Piasecki
Adam Piasecki
Jakub JuraszJakub Jurasz
Jakub Jurasz
AKAlexander Kies
Alexander Kies
Energy system research requires input data with high temporal and spatial resolution. However, the measurements performed in meteorological stations are only available for selected locations. Currently a growing number of research papers on small and large-scale power systems utilizes data coming from satellite measurements and various reanalyses. Although many authors aimed at comparing various data sources on irradiation and wind speed there is a lack of such studies, which compare both resources simultaneously at the same location. In consequence, many studies which are entirely based on satellite/reanalysis data may not be representative. In this paper 15 locations in Poland have been selected where the National Institute of Meteorology and Water Management performs continuous measurements of wind speed, temperature and global irradiation on a horizontal surface. Hourly time series were obtained for the year 2012 and 2013. The renewable resources were converted into electrical energy, considering the performance of typical PV panels and wind turbines. The findings of this study are as follows: solar radiation (CAMS and ERA5) shows a good agreement with ground measurements, for hourly values the coefficient of correlations is greater than 0.9; for individual locations the energy yield from PV system can differ by up to 9% but on average (all locations) the simulated energy yield based on satellite data is higher by less than 0.5%; simulations for wind energy showed a large variability in results with differences in capacity factors reaching 15 percentage points.

13 June 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
Jakub JuraszJakub Jurasz
Jakub Jurasz
AKAlexander Kies
Alexander Kies
Variable renewable energy sources (VRES), such as solarphotovoltaic (PV) and wind turbines (WT), are starting to play a significant role in several energy systems around the globe. To overcome the problem of their non-dispatchable and stochastic nature, several approaches have been proposed so far. This paper describes a novel mathematical model for scheduling the operation of a wind-powered pumped-storage hydroelectricity (PSH) hybrid for 25 to 48 h ahead. The model is based on mathematical programming and wind speed forecasts for the next 1 to 24 h, along with predicted upper reservoir occupancy for the 24th hour ahead. The results indicate that by coupling a 2-MW conventional wind turbine with a PSH of energy storing capacity equal to 54 MWh it is possible to significantly reduce the intraday energy generation coefficient of variation from 31% for pure wind turbine to 1.15% for a wind-powered PSH The scheduling errors calculated based on mean absolute percentage error (MAPE) are significantly smaller for such a coupling than those seen for wind generation forecasts, at 2.39% and 27%, respectively. This is even stronger emphasized by the fact that, those for wind generation were calculated for forecasts made for the next 1 to 24 h, while those for scheduled generation were calculated for forecasts made for the next 25 to 48 h. The results clearly show that the proposed scheduling approach ensures the high reliability of the WT–PSH energy source.