André Lerch

Prof. André Lerch

Technische Universitaet Dresden, Faculty of Environmental Sciences, Institute of Urban and Industrial Water Management, Chair of Process Engineering in Hydro Systems
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2018 in Membranes
Verified
Journal Article
Open access
PDF file
AHAnita Haupt
Anita Haupt
André LerchAndré Lerch
André Lerch
Forward osmosis (FO) is a membrane technology that uses the osmotic pressure difference to treat two fluids at a time giving the opportunity for an energy-efficient water and wastewater treatment. Various applications are possible; one of them is the application in industrial water management. In this review paper, the basic principle of FO is explained and the state-of-the-art regarding FO application in manufacturing industries is described. Examples of FO application were found for food and beverage industry, chemical industry, pharmaceutical industry, coal processing, micro algae cultivation, textile industry, pulp and paper industry, electronic industry, and car manufacturing. FO publications were also found about heavy metal elimination and cooling water treatment. However, so far FO was applied in lab-scale experiments only. The up-scaling on pilot- or full-scale will be the essential next step. Long-term fouling behavior, membrane cleaning methods, and operation procedures are essential points that need to be further investigated. Moreover, energetic and economic evaluations need to be performed before full-scale FO can be implemented in industries.

1 July 2005 in Desalination
Verified
Journal Article
Closed access
SSS. Strugholtz
S. Strugholtz
KSK. Sundaramoorthy
K. Sundaramoorthy
Stefan PanglischStefan Panglisch
Stefan Panglisch
André LerchAndré Lerch
André Lerch
ABA. Brügger
A. Brügger
RGR. Gimbel
R. Gimbel

1 July 2005 in Desalination
Verified
Journal Article
Closed access
André LerchAndré Lerch
André Lerch
Stefan PanglischStefan Panglisch
Stefan Panglisch
PBPatrick Buchta
Patrick Buchta
YTYoshiho Tomita
Yoshiho Tomita
HYHitoshi Yonekawa
Hitoshi Yonekawa
RGRolf Gimbel
Rolf Gimbel

1 January 2021 in Journal of Membrane Science
Verified
Journal Article
Closed access
JSJ. Schnittger
J. Schnittger
JMJ. McCutcheon
J. McCutcheon
THT. Hoyer
T. Hoyer
MWM. Weyd
M. Weyd
GFG. Fischer
G. Fischer
André LerchAndré Lerch
André Lerch

12 February 2021 in Membranes
Verified
Journal Article
Open access
PDF file
HRHanna Rosentreter
Hanna Rosentreter
Marc WaltherMarc Walther
Marc Walther
André LerchAndré Lerch
André Lerch
Saline groundwater (SGW) is an alternative water resource. However, the concentration of sodium, chloride, sulphate, and nitrate in SGW usually exceeds the recommended guideline values for drinking water and irrigation. In this study, the partial desalination performance of three different concentrated SGWs were examined by pressure-driven membrane desalination technologies: nanofiltration (NF), brackish water reverse osmosis (BWRO), and seawater reverse osmosis (SWRO); in addition to one electrochemical-driven desalination technology: membrane capacitive deionisation (MCDI). The desalination performance was evaluated using the specific energy consumption (SEC) and water recovery, determined by experiments and simulations. The experimental results of this study show that the SEC for the desalination of SGW with a total dissolved solid (TDS) concentration of 1 g/L by MCDI and NF is similar and ranges between 0.2–0.4 kWh/m3 achieving a water recovery value of 35–70%. The lowest SECs for the desalination of SGW with a TDS concentration ≥2 g/L were determined by the use of BWRO and SWRO with 0.4–2.9 kWh/m3 for a water recovery of 40–66%. Even though the MCDI technique cannot compete with pressure-driven membrane desalination technologies at higher raw water salinities, this technology shows a high selectivity for nitrate and a high potential for flexible desalination applications.

17 July 2018 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
AHAnita Haupt
Anita Haupt
André LerchAndré Lerch
André Lerch
Forward osmosis (FO) is a potential membrane technology to treat wastewater energy efficiently with low fouling. In laboratory-scale experiments, six effluents from a dairy and an automobile production plant were tested to find out if FO is an applicable treatment technology. Permeate flux and reverse salt flux were determined in nine test series with three subsequent 5 h experiments each. In between, the membrane was cleaned with deionized water. Membrane performance tests before each experiment were used to monitor membrane performance and fouling. Samples were analysed and the T/M-value was introduced to indicate which substances caused fouling. Dairy cheese brine was a suitable DS. Here, permeate fluxes were 21.0 and 15.1 L/(m²·h). Automobile cooling tower water and wastewater from cathodic dip painting were also used as DS. However, permeate fluxes were below 1.1 L/(m²·h). The tested FS, reverse osmosis concentrate from dairy wastewater treatment, rinsing water and wastewater from automobile cathodic dip painting, as well as wastewater from automobile paint shop pre-treatment, showed good performance regarding the permeate flux of between 7.9 and 19.4 L/(m²·h). Membrane performance test showed that some of the effluents lead to permeate flux reduction due to fouling. Different cleaning-in-place methods were examined. Eventually, permeate flux was restored.