To obtain rapid biodegradable biomaterials, a biodegradable triblock oligomer poly(lactic acid)-poly(ethylene glycol)-poly(lactic acid) (PLA-PEG-PLA) was designed and synthesized as a soft segment of polyurethane. Then new nontoxic biodegradable polyurethanes were prepared using the same stoichiometric ratio of PLA-PEG-PLA, L-lysine ethyl ester diisocyanate (LDI), and 1,4-butanediol (BDO). The molecular weights of polyurethanes were controlled by adjusting the polymerization temperature. The resulting polyurethanes were characterized by gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), and differential scanning calorimetry (DSC). Furthermore, the biodegradability of the synthesized polyurethanes was evaluated at 37 °C in phosphate buffer solutions (PBS) under different pH values and enzymatic solution at pH 7.4. The results showed that these polyurethanes could be rapidly degraded in PBS and enzymatic solution, as demonstrated by weight loss measurements and scanning electron microscope (SEM) observations. The degradation rates of these polyurethanes were mainly regulated by microphase separation degree, and could be restrained in lower pH value PBS. Moreover, the degradation products did not significantly decrease the pH value of incubation media, which would be useful to improve biocompatibilities of these polyurethanes in vivo. The current work provides a more promising approach to prepare nontoxic biodegradable polyurethanes with rapid degradation rates. These new materials may find potential use for drug delivery systems and magnetic resonance imaging (MRI) contrast agents.
9 March 2011 in Journal of Polymer Science Part A: Polymer Chemistry
In order to analyze the cracking and aging reason of the silicone rubber current transformer (CT) insulation bushing used for 8 years from a 500 kV alternating current substation, characteristics including Fourier transform infrared (FTIR) spectroscopy, mechanical properties analysis, hardness, and thermo gravimetric analysis have been carried out. The FTIR results indicated that the external surface of the silicone rubber CT insulation bushing suffered from more serious aging than the internal part, fracture of side chain Si–C bond was much more than the backbone. Mechanical properties and thermal stability results illustrated that the main aging reasons were the breakage of side chain Si–C bond and the excessive cross-linking reaction of the backbone. This study can provide valuable basis for evaluating degradation mechanism and aging state of the silicone rubber insulation bushing in electric power field.
4 November 2016 in Phosphorus, Sulfur, and Silicon and the Related Elements
The cracking and reasons for aging of silicone rubber current transformer insulation sheath from a 500 kV substation were investigated. Chemical characteristics including attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, mechanical properties, and thermo gravimetric analysis (TGA) have been performed on the external surface and internal parts of the silicone rubber CT insulation sheath. The FTIR results indicated that the external surface of the silicone rubber CT insulation sheath suffered from more serious aging than the inner, fracture of the side chain (Si-C bond) was much more than the backbone (Si-O bond). Mechanical test results revealed that the tensile strengths of the external surface parts of the silicone rubber CT insulation sheath were lower than those of the internal parts. TG analysis data indicated that Tonset dropped nearly 50°C for the external surface of the silicone rubber CT insulation sheath. All the chemical characteristics have showed that the external surface material of the silicone rubber CT insulation sheath had been serious aging. Our work suggested a facile and effective method for evaluating the aging state of the silicone rubber insulation sheath in the electric power field from the perspective of chemical.
Corrosion defects will increase the risk of power equipment failure, which will directly affect the stable operation of power systems. Although existing methods can detect the corrosion of equipment, these methods are often poor in real-time. This study presents a two-stage detection approach that combines YOLOv8 and DDRNet to achieve real-time and precise corrosion area localization. In the first stage, the YOLOv8 network is used to identify and locate substation equipment, and the detected ROI areas are passed to the DDRNet network in the second stage for semantic segmentation. To enhance the performance of both YOLOv8 and DDRNet, a multi-head attention block is integrated into their algorithms. Additionally, to address the challenge posed by the scarcity of corrosion defect samples, this study augmented the dataset using the cut-copy-paste method. Experimental results indicate that the improved YOLOv8 and DDRNet, incorporating the multi-head attention block, boost the mAP and mIoU by 5.8 and 9.7, respectively, when compared to the original method on our self-built dataset. These findings also validate the effectiveness of our data augmentation technique in enhancing the model’s detection accuracy for corrosion categories. Ultimately, the effectiveness of the proposed two-stage detection method in the real-time detection of substation equipment corrosion defects is verified, and it is 48.7% faster than the one-stage method.
In order to effectively reduce and retard corrosion of the power transmission and transformation equipment in Chengdu power grid and to improve power supply reliability, Q235 carbon steel material which is the most widely used metal material in power grid was selected as the targeted research object in this article. Exposure experiments were performed in urban atmospheric environment of Chengdu city in the southwest region of China. The corrosion behavior of Q235 carbon steel material was investigated at different seasons. The macro- and micromorphologies after corrosion were observed using a digital camera and scanning electron microscopy (SEM), respectively. Element distribution of the rust layer and the corrosion products was characterized by energy-dispersive spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR); the corrosion mechanism was also briefly analyzed.