As the coronavirus 2019 (COVID-19) began spreading globally with no clear treatment in sight, prevention became a major part of controlling the disease and its effects. COVID-19 spreads from the aerosols of an infected individual whether they are showing any symptoms or not. Therefore, it becomes nearly impossible to point exactly where the patient is. This is where personal protective equipment (PPE) comes in. These are masks, respirators, gloves, and in hospitals where the contact with the infected and confirmed patient is direct, also gowns or body covers. The PPEs play a major role in the prevention and control of the COVID-19. The PPE is able to prevent any invasion of the virus particles into the system of an individual which is why it is an essential item to have for healthcare workers. Due to the high demand for PPEs all around the world, it is important to optimize the use of protective gear and ration the supplies so that the demand are met. However, there are guidelines recommended by the World Health Organization (WHO) and the Centers for Disease Control and Prevention (CDC) to maintain the supply in the wake of this increased demand of PPE, how the manufacturers should track their supplies, and how the recipients should manage them. Various strategies can be used to increase the re-use of PPEs during the COVID-19 pandemic that has modified the donning and doffing procedure.
Balochistan is the largest of Pakistan's four provinces, yet it is also the poorest and most impoverished, particularly in terms of neonatal healthcare. In order to build and tailor strategies to improve neonatal outcomes, it is necessary to identify barriers and facilitators for interventions. Therefore, we conducted this study to provide an overview of neonatal healthcare quality and assess the structural capacity for the improvement and further development of neonatal healthcare facilities in Balochistan. A descriptive, observational, cross-sectional study was conducted in Balochistan, a province of Pakistan. The survey was designed to assess the level of staffing and facilities in the neonatal health care units. Data were gathered through trained staff either by in-person visits to the facility or via telephone. A total of 177 facilities were assessed in 25 districts of Balochistan. A majority (88.7%) of the facilities were from the public sector. Birth and neonatal care services were provided at only 63 (36%) of the assessed facilities and only three had newborn intensive care units (NICUs) with a 1:5 staff: patient ratio. Unfortunately, all NICUs lacked the basic advanced facilities. None of the hospitals had an infection control policy or staff nor any training program for doctors. In conclusion, healthcare facilities to manage neonatal patients requiring hospital care are extremely limited in Balochistan and the ones that are available have very limited resources. To improve the healthcare system in Balochistan, all stakeholders should be involved in the planning, decision-making, and implementation of healthcare programs at all levels to ensure sustainability and efficiency.
The spread of COVID-19 has been exponential throughout the globe. Though only a small percentage of infected individuals reach the critical stage of the disease, i.e., acute respiratory distress syndrome (ARDS), this percentage represents a significant number of patients that can overwhelm the healthcare system. Patients presenting with ARDS need mechanical ventilation, as their lungs are unable to oxygenate blood on their own due to fluid accumulation. One way to manage this excess pressure of fluid build-up around the lung tissues is to relieve the dorsal alveoli by prompting the patient to lie face down on the stomach; this is called awake proning. It is a procedure that is directed towards the recruitment of lung parenchyma when infected with pneumonia or when the condition has worsened into ARDS. This helps in relieving the pressure from the dorsal lung surface that has markedly higher perfusion than the ventral surface. Awake proning delays the use of mechanical ventilation and facilitates the patients with severe ARDS or severe pneumonia in maintaining the supply of oxygen to the body tissues. Since medical institutes are overburdened and limited ventilators are available, awake proning can reduce not only the burden on hospitals but also decrease the need for ventilators.
Turner syndrome (TS), or Bonnevie-Ullrich syndrome, also known as congenital ovarian hypoplasia syndrome, is the most common sex chromosome abnormality in females in approximately 1 in 2000 live birth. It occurs when the X chromosome is partially or completely missing in females caused by monosomy or structural abnormalities of the X chromosome. It is mainly diagnosed in late childhood or adolescent age and rarely identified during the neonatal period. It is characterized by short stature, webbed neck, lymphedema of extremities, widely spaced-out nipples, and cubital valgus. Early diagnosis of TS allows for appropriate and timely initiation of therapy with comprehensive care. We report a case of a neonate presented with the complaint of edema of feet since birth and syndromic features. TS was diagnosed by the chromosomal analysis, which demonstrated a gene karyotype of 46.X,i(X)(q10){20}.
Objective: Extubation failure is common in mechanically ventilated neonates. Finding objective criteria for predicting successful extubation may help to reduce the incidence of failure and the length of mechanical ventilation (MV). We conducted this study to determine the accuracy of the spontaneous breathing trial (SBT) and lung function measurements in predicting successful extubation in neonates. Methodology: This cross-sectional validation study was conducted at a tertiary care neonatal intensive care unit (NICU) over 12 months from December 2019 to December 2020. Neonates intubated for >24 hours and considered ready for extubation were enrolled in the study. Neonates who met defined eligibility criteria underwent a three minutes SBT using endotracheal continuous positive airway pressure (ET-CPAP) before extubation. The primary clinical team was blinded to the results, and all neonates were extubated after SOT. Extubation was considered successful if patients remained extubated for 48 hours. Results: Among the 107 infants, 77.5% (n=83) of infants passed the SBT. Of these, 78 were successfully extubated, giving the positive predictive value of 93.97%. The overall extubation success rate was 90% (n=96). The sensitivity and specificity of SBT were 81.2% and 54.5%, respectively. VE (ET-CPAP) and VE-ventila tor at a cutoff of >= 238 ml and >= 143.7 ml have an area under the curve (AUC) of 0.77 and 0.75 respectively to predict successful extubation (p-value 0.003, 0.008 respectively). Conclusion: SBT predicts extubation success with pronounced accuracy. Therefore, we propose SBT as a valuable and crucial step that guides clinicians' decision-making regarding extubation preparedness or impending failure in neonates.
Introduction Conventionally, various parenteral nutrition (PN) components are individually administered considering an individual neonate's requirements. More recently, standardized PN (SPN) formulations have been initiated for preterm neonates, which may benefit from the enhanced nutrient supply, less administration and prescription errors, reduced risk of infectious disease, and cost-effectiveness. Methodology A multicentered, pre-post intervention-based study was conducted at tertiary neonatal intensive care units (NICUs) in Karachi, Pakistan. Post-graduate residents of neonatology and pediatrics working in NICUs were included in the study, and their perspective was attained regarding PN formulation and a prescription for time consumption, ease, calculation errors, and general feedback. Independent T-test was applied to assess the statistical difference between the pre-and post-implementation of PN formulation for total time required for PN calculation, whereas for the rest of the quantitative variables Mann-Whitney U test was computed. Results The total time required to do the entire writing process, calculating and ordering PN, was 17.1 +/- 6.9 whereas significantly (p-value of <0.0001) reduced to 10.5 +/- 5.7 after implementing SPN prescriptions. Calculation errors were reduced from 32% to 12%, and writing errors were also decreased from 35% to 8% when the standardized parenteral nutritional formulation was applied. Conclusion Our findings show that implementing standardized prescriptions in the NICU has improved medication safety, with the most consistent benefit by reducing medication errors and time management. The SPN prescriptions save time for post-graduate residents, physicians, and pharmacists by eliminating previously required repetitive activities and calculations.