Gyoo-Suk Kim

Gyoo-Suk Kim


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YHYoon Heo
Yoon Heo
HCHyuk-Jae Choi
Hyuk-Jae Choi
SHSeok-Jin Hwang
Seok-Jin Hwang
JLJong-won Lee
Jong-won Lee
CKChil-Yong Kwon
Chil-Yong Kwon
GKGyoo-Suk Kim
Gyoo-Suk Kim
Gait training for paraplegic patients is effective in preventing various complications due to prolonged sitting. In these patients, the use of powered exoskeletal-gait-orthosis (EGO) consumes lower energy than traditional training methods using non-powered EGO, such as a reciprocating-gait-orthosis (RGO). Thus, long-term training is possible and effective in increasing the activity level of the trunk muscles. However, more than 60% of paraplegic patients have incomplete injuries with residual function, which is inversely related to the functional role of the orthosis. We hypothesized that the gait ability in incomplete paraplegia could be improved by knee joint activation, and we developed a lightweight knee-actuated EGO (KAEGO). We verified its effectiveness in one patient with an incomplete spinal cord injury by comparing the metabolic cost of transport (COT) measured by a six minute walk test to a traditional non-powered EGO. We found that with increasing assist torque to the knee joint, the COT decreased by up to 24.5%, and the gait performance, including walking speed and travel distance, significantly improved up to 37% compared to that of the non-powered EGO. Future studies should verify the KAEGO system’s effectiveness in a larger number of patients with various injury levels.

30 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YCYunhee Chang
Yunhee Chang
JKJungsun Kang
Jungsun Kang
GKGyoo-Suk Kim
Gyoo-Suk Kim
HSHyunjun Shin
Hyunjun Shin
SPSehoon Park
Sehoon Park
Lower limb amputees (LLAs) have a high incidence of low back pain (LBP), and identifying the potential risk factors in this group is key for LBP prevention. This study analyzed the intramuscular properties of the resting lumbar muscle in thirteen unilateral LLAs and age-matched controls to predict the onset of LBP. To measure the lumbar intramuscular properties, resting erector spinae muscles located in the upper and lower lumbar regions were examined using a handheld myotonometer. The dynamic stiffness, oscillation frequency, and logarithmic decrement were measured. In our results, the stiffness and frequency of the upper lumbar region were greater in the amputee group than in the control, whereas the decrement did not differ between the two groups. Additionally, the measured values in the lower lumbar region showed no significant difference. Within each group, all three factors increased at the upper lumbar region. In the LLAs, the frequency and stiffness values of the upper lumbar on the non-amputated side were significantly higher than those on the amputated side. These results indicate that the upper lumbar muscles of the amputees were less flexible than that of the control. This study can help in providing therapeutic strategies treating LBP in amputees.

29 January 2022 in Machines
Verified
Journal Article
Open access
PDF file
JLJong-won Lee
Jong-won Lee
JBJuhwan Bae
Juhwan Bae
HCHyuk-Jae Choi
Hyuk-Jae Choi
CKChilyong Kwon
Chilyong Kwon
YHYoon Heo
Yoon Heo
GKGyoo-Suk Kim
Gyoo-Suk Kim
Reciprocating gait orthosis (RGO) is a traditional passive orthosis that provides postural stability and allows for independent upright ambulation with the assistance of walking aids, such as crutches, canes, and walkers. Previous follow-up studies of patients with RGOs have indicated a high frequency of nonusage. One of the main reasons for avoiding the use of RGOs is the excessive upper extremity loading induced by walking aids. The purpose of this study was to investigate the effect of hip actuation on the upper extremity loading induced by crutches when ambulating with an RGO. One female individual with a chronic complete spinal cord injury classified as ASIA A participated in this study. We compared the upper extremity loading during ambulation when individualized hip assistive forces were applied on the RGO (POWERED condition) and when wearing the RGO without actuation (RGO condition). Upper extremity loading was assessed by measuring the forces acting on the crutches. Compared with the RGO condition, the average upper extremity loading per unit distance and per unit time were lower for the POWERED condition by 15.21% (RGO: 0.307 ± 0.056 and POWERED: 0.260 ± 0.034 %bw·m−1) and by 21.19% (RGO: 0.120 ± 0.020 and POWERED: 0.094 ± 0.011 %bw·s−1), respectively. We believe that a substantial reduction in upper extremity loading during ambulation provided by hip actuation holds promise to promote long-term RGO use and enable patients with paraplegia to perform frequent and intensive rehabilitation training. As this is a single case study, subsequent studies should aim to verify this effect through a higher number of patients and to different injury levels.

12 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YCYunhee Chang
Yunhee Chang
JKJungsun Kang
Jungsun Kang
BJBora Jeong
Bora Jeong
YKYongcheol Kim
Yongcheol Kim
EHEung-Pyo Hong
Eung-Pyo Hong
GKGyoo-Suk Kim
Gyoo-Suk Kim
To minimize body collapse due to repetitive reclining and repositioning when using a reclining wheelchair, reclining wheelchairs with a sliding backrest function have been developed. This study compared the differences in body-slip and buttock pressure according to the presence or absence of the sliding function of the backrest during reclining and repositioning motions in 10 patients with spinal cord injury. When reclining from 100° to 130°, backrest sliding and total body-slip in the double-sliding wheelchair were significantly decreased by 21.4 mm and 16.4 mm, respectively, compared to a non-sliding wheelchair, and the peak pressure on the ischial tuberosity was significantly decreased by 8.7 kPa. Upon comparison of the buttock pressure between the initial upright position before reclining and the return upright position after repositioning, the force and mean pressure with the double-sliding wheelchair were significantly reduced compared with those with the non-sliding wheelchair. It was confirmed that the double-sliding system improved body-slip and buttock pressure more effectively than the non-sliding system. This study’s results are expected to provide the basic data necessary for the prescription and selection of wheelchairs in clinical practice and to be utilized in the development of related devices.

31 May 2024 in Journal of Biomechanics
Verified
Journal Article
Closed access
HCHyuk-Jae Choi
Hyuk-Jae Choi
JCJunwon Choi
Junwon Choi
GKGyoo-Suk Kim
Gyoo-Suk Kim
HKHan Sung Kim
Han Sung Kim
CKChang-Yong Ko
Chang-Yong Ko

1 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CKChil-Yong Kwon
Chil-Yong Kwon
Jungsik JangJungsik Jang
Jungsik Jang
GKGyoo-Suk Kim
Gyoo-Suk Kim
Wearable robots that assist paraplegia patients should be manufactured according to the shape of the individual wearer. With the development of advanced three-dimensional (3D) printing technologies, such customizations are becoming available. However, conventional 3D printing customization requires extensive template remodeling, which is non-productive and inefficient. This study proposes a 3D-printed (3DP) physical human–robot interface (pHRI) based on a sizing system that facilitates customization to body shapes. The proposed system is a pre-developed pHRI in various sizes and shapes using a human body shape database. Conformity of shapes and dimensions were evaluated visually via shape deviation analysis for 10 persons having paraplegia. With the proposed 3DP-pHRI, the trunk comprised 18 sections and the shank comprised nine. A biased trend of coverage rates in the shank 3DP-pHRI size system was identified. The trunk and shank subsystems were found to be adequate in terms of shapes and dimensions, with values within the mean deviation range of ±10 mm. A novel 3DP-pHRI size system facilitating customization tool for fabricating wearable robots for paraplegia patients according to body shape was developed, and its effectiveness was assured. The new system can be used for various wearable robot pHRIs, and the database is expected to supply a comprehensive pHRI template library.