Jiayin Zhu

Prof. Jiayin Zhu


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
Ruixin LiRuixin Li
Ruixin Li
YZYiwan Zhao
Yiwan Zhao
GLGaochong Lv
Gaochong Lv
Weilin LiWeilin Li
Weilin Li
JZJiayin Zhu
Jiayin Zhu
OBOlga L. Bantserova
Olga L. Bantserova
Near-wall microenvironment of a building refers to parameters such as wind speed, temperature, relative humidity, solar radiation near the building’s façade, etc. The distribution of these parameters on the building façade shows a certain variation based on changes in height. As a technology of passive heating and ventilation, the effectiveness of this application on heat collection wall is significantly affected by the near-wall microclimate, which is manifested by the differences, and rules of the thermal process of the components present at different elevations. To explore the feasibility and specificity of this application of heat collection wall in high-rise buildings, this study uses three typical high-rise buildings from Zhengzhou, China, as research buildings. Periodic measurements of the near-wall microclimate during winter and summer were carried out, and the changing rules of vertical and horizontal microclimate were discussed in detail. Later, by combining these measured data with numerical method, thermal process and performance of heat collection wall based on increasing altitude were quantitatively analyzed through numerical calculations, and the optimum scheme for heat collection wall components was summarized to provide a theoretical basis for the structural design of heat-collecting wall in high-rise buildings.

21 November 2022 in Processes
Verified
Journal Article
Open access
PDF file
Ruixin LiRuixin Li
Ruixin Li
GLGaoyi Liu
Gaoyi Liu
XYXia Yuanli
Xia Yuanli
OBOlga L. Bantserova
Olga L. Bantserova
Weilin LiWeilin Li
Weilin Li
JZJiayin Zhu
Jiayin Zhu
Since the 21st century, in several public health emergencies that have occurred across the world, the humid enclosed environment of the toilet has become one of the places where bacteria, viruses, and microorganisms breed and spread. Mobile public toilets, as a supplement of urban fixed public toilets, are also widely used in densely populated areas. According to statistics, since the outbreak of COVID-19 in 2019, multiple incidents of people being infected by the COVID-19 virus due to aerosol proliferation in public toilets have been confirmed. It is an urgent issue to resolve the internal environmental pollution of mobile public health and reduce the risk of virus transmission in public spaces under the global epidemic prevention. This paper utilized a typical combined mobile public toilet as the research object and measured and evaluated the indoor thermal environment in real time over a short period of time. The diffusion mode and concentration change law of pollutants in mobile public toilets were predicted and analyzed based on CFD. Regression analysis was also used to clarify the relationship between indoor thermal environment variables and aerosol diffusion paths, and a ventilation optimization scheme was proposed to reduce the risk of virus transmission.

2 June 2023 in Indoor Air
Verified
Journal Article
Open access
PDF file
Ruixin LiRuixin Li
Ruixin Li
YMYuxin Ma
Yuxin Ma
CJChen Jiacong
Chen Jiacong
OBOlga L. Bantserova
Olga L. Bantserova
JZJiayin Zhu
Jiayin Zhu
Yu ChenYu Chen
Yu Chen
Clothing can absorb fine particulate pollutants from the atmosphere outdoors and then release them after entering the room in a form similar to three-handed smoke. In this study, the experimental site in Zhengzhou, a typical city with heavy pollution in central China, was used to investigate the adsorption and diffusion patterns of three different fabrics of polyester, polyester-cotton, and cotton clothing for fine particle pollutants, to guide peoples behavior patterns and indoor air distribution, and to reduce indoor pollution exposure. The results showed that when garments of three different fabrics were exposed to moderate and heavy PM2.5 pollution for 1h, 2h, and 3h, respectively, and then transferred to the diffusion chamber, polyester always released the highest PM2.5 concentration to indoor air during the same release cycle, followed by cotton and polyester-cotton. In addition, the concentration of indoor air pollutants will be periodically affected by the diffusion of fine particulate adsorbed by clothing fabrics. With the increase in outdoor pollution and exposure duration, the indoor PM2.5 concentration takes longer to stabilize at certain levels after the clothing is transferred to the indoor side. Finally, the comparison of natural ventilation experiments proved that it is not feasible to rely solely on natural ventilation to improve the influence of clothing pollution sources on indoor air quality.

10 October 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
JZJiayin Zhu
Jiayin Zhu
XLXin Liu
Xin Liu
ZXZihan Xu
Zihan Xu
XZXingtao Zhang
Xingtao Zhang
CDCongcong Du
Congcong Du
Ruixin LiRuixin Li
Ruixin Li
With the increasing intelligence of modern air-conditioning systems, the difficulty of acquiring data from air-conditioning systems has been significantly reduced. However, analyzing the massive amounts of data collected and obtaining more valuable information still remains challenging, especially considering the internal relationships behind the data. The purpose of this study was to conduct operational experiments on VRF systems under different indoor set temperatures, indoor set air speeds, and terminal load rates. Then, the patterns of various operating parameters and energy consumption of VRF systems during winter operation were analyzed based on unsupervised methods. Three machine learning methods were primarily employed in this study, including correlation analysis, data regression analysis, and association rule analysis. Finally, a regression model was constructed for energy consumption based on eight typical characteristic parameters. The experimental results showed that the system was stable to a certain degree at different wind speeds. Among the characteristic parameters, fixed frequency 1 exhaust temperature, compressor frequency, and other parameters have a significant positive effect on energy consumption, while fixed frequency 1 shell top oil temperature, inlet and outlet pipe temperature difference, and other parameters have a negative effect. The research results provide a reference for air conditioning system data mining and building sustainability.