COVID-19 Antibody Detecting Rapid Diagnostic Tests (COVID-19 Ab RDTs) are the preferred tool for SARS-CoV-2 seroprevalence studies, particularly in low- and middle-income countries. The present study challenged COVID-19 Ab RDTs with pre-pandemic samples of patients exposed to tropical pathogens. A retrospective study was performed on archived serum (n = 94) and EDTA whole blood (n = 126) samples obtained during 2010–2018 from 196 travelers with malaria (n = 170), schistosomiasis (n = 25) and dengue (n = 25). COVID-19 Ab RDTs were selected based on regulatory approval status, independent evaluation results and detecting antigens. Among 13 COVID-19 Ab RDT products, overall cross-reactivity was 18.5%; cross-reactivity for malaria, schistosomiasis and dengue was 20.3%, 18.1% and 7.5%, respectively. Cross-reactivity for current and recent malaria, malaria antibodies, Plasmodium species and parasite densities was similar. Cross-reactivity among the different RDT products ranged from 2.7% to 48.9% (median value 14.5%). IgM represented 67.9% of cross-reactive test lines. Cross-reactivity was not associated with detecting antigens, patient categories or disease (sub)groups, except for schistosomiasis (two products with ≥60% cross-reactivity). The high cross-reactivity for malaria, schistosomiasis and—to a lesser extent—dengue calls for risk mitigation when using COVID-19 Ab RDTs in co-endemic regions.
HIV-1 pol sequences obtained through baseline drug resistance testing of patients newly diagnosed between 2013 and 2017 were analyzed for genetic similarity. For 927 patients the information on genetic similarity was combined with demographic data and with information on the recency of infection. Overall, 48.3% of the patients were genetically linked with 11.4% belonging to a pair and 36.9% involved in a cluster of ≥3 members. The percentage of early diagnosed (≤4 months after infection) was 28.6%. Patients of Belgian origin were more frequently involved in transmission clusters (49.7% compared to 15.3%) and diagnosed earlier (37.4% compared to 12.2%) than patients of Sub-Saharan African origin. Of the infections reported to be locally acquired, 69.5% were linked (14.1% paired and 55.4% in a cluster). Equal parts of early and late diagnosed individuals (59.9% and 52.4%, respectively) were involved in clusters. The identification of a genetically linked individual for the majority of locally infected patients suggests a high rate of diagnosis in this population. Diagnosis however is often delayed for >4 months after infection increasing the opportunities for onward transmission. Prevention of local infection should focus on earlier diagnosis and protection of the still uninfected members of sexual networks with human immunodeficiency virus (HIV)-infected members.
While the detection of HIV infection is accomplished by several methods, the most common are serological tests that detect host antibodies produced in response to viral infection. However, the use of current serological tests may present a significant challenge to the adoption of an HIV vaccine in the future because the antibodies to HIV antigens detected in currently available tests also tend to be included as antigens in the HIV vaccines in development.
Background: The cobas Plasma Separation Card (PSC; Roche Diagnostics) was developed for HIV viral load testing. This study evaluates the performance of HIV and Treponema pallidum (Tp) antibody (Ab) detection on PSCs as an alternative to dried blood spots (DBSs). Methods: EDTA whole blood samples were collected from HIV-positive (n = 100), HIV-negative (n = 50), Tp-positive (n = 100), and Tp-negative patients (n = 50) and spotted on DBS and PSC. Antibody detection performance was evaluated for HIV Ab using the Genscreen ULTRA HIV Ag-Ab test (Bio-Rad) and for Tp Ab using the Syphilis Total Ab test (Bio-Rad). Plasma was used as a reference specimen. Results: Receiver operating characteristic curve analysis for DBS and PSC generated areas under the curve (AUC + 95% confidence interval) of 0.985 (0.960–1.000) and 0.987 (0.973–1.000) for HIV Ab and 1.000 (1.000–1.000) and 0.996 (0.983–1.000) for Tp Ab, respectively. Receiver operating characteristic areas under the curve were not significantly different between DBS and PSC for HIV or TP Ab. At selected cutoff values rendering at least 99% sensitivity for HIV Ab detection, the specificity was 96% on DBS and 68% on PSC. For Tp Ab detection at 90% sensitivity, 100% specificity is reached on both DBS and PSC (exceeding the required 95%). However, the median quantitative HIV and Tp Ab signal of positive samples significantly decreased in PSC compared with DBS and plasma. Conclusions: Although receiver operating characteristic analysis does not seem to indicate significant differences in performance between DBS and PSC, the significant reduction in quantitative Ab detection signal dictates card composition optimization before its use for HIV and Tp Ab detection can be advised.
The international spread of HIV-1 sub-subtype A6 raises concerns due to its association with contraindications for long-acting injectable formulations of cabotegravir (LA-CAB) and rilpivirine (LA-RPV). This study investigated its increasing proportion in Belgium, assessing transmission dynamics and potential migration links. Additionally, genotypic drug resistance in the Belgian HIV-1 sub-subtype A6 population were analyzed and four automatic subtyping tools were compared. A dataset of 4764 HIV-1 protease and reverse transcriptase (RT) sequences from newly diagnosed, treatment-naïve individuals in Belgium (2013–2022) was analyzed. A combination of phylogenetic analysis and online subtyping tools identified 136 sub-subtype A6 sequences. The increase in the proportion of HIV-1 sub-subtype A6 observed in Belgium since 2020 reflects changing transmission patterns, especially among Belgium-born men having sex with men, and cannot be solely linked to the recent influx of Ukrainian migrants. Of these sub-subtype A6 sequences, less than 10% showed LA-CAB + LA-RPV resistance, mainly due to E138A within RT. HIVdb and ANRS reliably assessed resistance in this therapy-naïve cohort, and HIVdb, COMET, and SmartGene® produced concordant subtyping results. While algorithm choice has little impact at low resistance prevalence, further research is necessary and HIVdb and ANRS remain more suitable for ongoing clinical and research use.
Background: The World Health Organisation recommends testing populations most affected by hepatitis C virus (HCV) infection, like people living with HIV. After screening with an Ab test, HCV RNA testing is required to identify active (viremic) infections. One could focus the HCV RNA testing capacity on true positive serological test results, by implementing serological HCV confirmation assays. Our goal was to evaluate the performance of 3 HCV confirmation assays in people living with HIV. Methods: A total of 415 frozen plasma specimens collected in Cambodia (Sihanouk Hospital Center of HOPE) and Belgium (Institute of Tropical Medicine) were tested with Geenius HCV supplemental Assay (Bio-Rad, Marne la Coquette, France), HCV Blot 3.0 (MP Biomedical, Irvine, CA), and INNO-LIA HCV Score (Fujirebio, Ghent, Belgium). Results were compared against HCV RNA results and/or a composite reference standard. Results: Overall, INNO-LIA had the highest sensitivity (97.0%; 95% confidence interval [CI], 94.0%–98.5%) and Geenius the highest specificity (98.2%; 95% CI, 93.7%–99.5%). In a subset of patients with active infection (n = 177), all 3 assays showed comparable sensitivity (99.0%; 95% CI, 96.0%–100.0%). Both for INNO-LIA (8.7% [36 of 415]) and HCV Blot (7.0% [29 of 415]), the indeterminate results were mostly negative and/or indeterminate (80.6% [29 of 36] and 93.1% [27 of 29], respectively) on the composite reference standard compared with only 26.3% (10 of 38) on Geenius. Conclusions: All 3 antibody confirmation assays show comparable and high sensitivity in active HCV infections. Geenius potentially offers some advantages in ease of use, low turnaround time, and ruling out past infections. The added value of HCV antibody confirmation assays needs to be established in larger cost-effectiveness studies and is influenced by decreasing HCV prevalence and HCV RNA capacity.