Sébastien ROBERT

Dr. Sébastien ROBERT

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
LMLucas Merabet
Lucas Merabet
SRSébastien ROBERT
Sébastien ROBERT
CPClaire Prada
Claire Prada
Time-domain Plane Wave Imaging (PWI) has recently emerged in medical imaging and is now taking to Non- Destructive Testing (NDT) due to its ability to provide images of good resolution and contrast with only a few steered plane waves. Insonifying a medium with plane waves is a particularly interesting approach in 3D imaging with matrix arrays because it allows to tremendously reduce the volume of data to be stored and processed as well as the acquisition time. However, even if the data volume is reduced with plane wave emissions, the image reconstruction in the time domain with a delay-and-sum algorithm is not sufficient to achieve low computations time in 3D due to the number of voxels. Other reconstruction algorithms take place in the f-k wavenumber-frequency domain and have been shown to accelerate computation times in seismic imaging and in Synthetic Aperture Radar (SAR). In this paper, we start from time-domain PWI in 2D and compare it to two algorithms in the wavenumberfrequency (f-k) domain, coming from the Stolt migration in seismic imaging and the Lu theory of limited diffraction beams in medical imaging. We then extend them to immersion testing configurations where a linear array is facing a plane water-steel interface. Finally, the reconstruction algorithms are generalized to 3D imaging with matrix arrays. A comparison dwelling on image quality and algorithmic complexities is provided, as well as a theoretical analysis of the image amplitudes and the limits of each method. We show that the reconstruction schemes in the wavenumber-frequency domain allow to improve the lateral resolution and offer a theoretical and numerical computation gain of up to 36 in 3D imaging in a realistic NDT configuration.

1 December 2020 in NDT & E International
Verified
Journal Article
Open access
CMCorentin Ménard
Corentin Ménard
SRSébastien ROBERT
Sébastien ROBERT
RMRoberto Miorelli
Roberto Miorelli
DLDominique Lesselier
Dominique Lesselier

26 February 2022 in Ultrasonics
Verified
Journal Article
Closed access
MMM. Marmonier
M. Marmonier
SRSébastien ROBERT
Sébastien ROBERT
LJLaurent Jérôme
Laurent Jérôme
CPC. Prada
C. Prada

3 April 2017 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
EVEduardo Lopez Villaverde
Eduardo Lopez Villaverde
SRSébastien ROBERT
Sébastien ROBERT
CPClaire Prada
Claire Prada
In this paper, defects in a high density polyethylene pipe are imaged with the total focusing method. The viscoelastic attenuation of this material greatly reduces the signal level and leads to a poor signal-to-noise ratio (SNR) due to electronic noise. To improve the image quality, the decomposition of the time reversal operator method is combined with the spatial Hadamard coded transmissions before calculating images in the time domain. Because the Hadamard coding is not compatible with conventional imaging systems, this paper proposes two modified coding methods based on sparse Hadamard matrices with +1/0 coefficients. The SNRs expected with the different spatial codes are demonstrated, and then validated on both simulated and experimental data. Experiments are performed with a transducer array in contact with the base material of a polyethylene pipe. In order to improve the noise filtering procedure, the singular values associated with electronic noise are expressed on the basis of the random matrix theory. This model of noise singular values allows a better identification of the defect response in noisy experimental data. Finally, the imaging method is evaluated in a more industrial inspection configuration, where an immersion array probe is used to image defects in a butt fusion weld with a complex geometry.

16 April 2008 in Waves in Random and Complex Media
Verified
Journal Article
Closed access
FLFrancine Luppe
Francine Luppe
JCJean-Marc Conoir
Jean-Marc Conoir
SRSébastien ROBERT
Sébastien ROBERT
Twersky's theory is generalized to multiple scattering by a uniform random distribution of cylinders in a poro-elastic medium. The high-frequency regime only, where no dispersion effects occur in the absence of scatterers, is investigated in the frame of Biot's theory. The scatterers lie within a slab of the host medium, and an incident wave gives rise to a fast longitudinal coherent wave, a slow longitudinal one, as well as a shear one in the slab. The dispersion equations of those three coherent waves are derived. The shear coherent wave propagates independently of the other two, while the longitudinal coherent waves obey a coupled dispersion equation involving conversion terms. Numerically speaking, coupling effects are significant only when forward scattering by a single cylinder of the fast wave into the slow one (or the slow wave into the fast) is larger than forward scattering with no conversion.

15 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CMCorentin Menard
Corentin Menard
SRSébastien ROBERT
Sébastien ROBERT
DLDominique Lesselier
Dominique Lesselier
The quality of ultrasound images of welds is highly penalized by the dendritic structure of the material that forms during cooling. The image of a flaw is all the more degraded as a reliable description of such a medium is most of the time not possible, due to the poor knowledge on the weld at time of inspection. In a previous work, we demonstrated the efficiency of an optimization procedure to correct a degraded Total Focusing Method (TFM) image of a point-like reflector inside a homogeneous weld, with uniaxial grain orientation. In the present contribution, this procedure is extended to more realistic welds with a varying grain orientation, and it is evaluated with a 64-element array emitting at 5 MHz on stainless steel weld samples featuring side-drilled holes of 1 mm diameter. A first proof of concept with simulated echoes, and then two experiments show that defects that were hardly visible on TFM images before the optimization are now well reconstructed and with positioning errors inferior to 1 mm.