The Department of Civil Protection (DPC), in compliance with the EU decision 1313/2013 and at the request of the Sendai Framework for Disaster Risk Reduction 2015–2030 to update the disaster risk assessments by various countries, released the latest National Risk Assessment for Italy at the end of 2018. Specifically, as regards the seismic risk assessment, six research units belonging to two centres of competence of the DPC collaborated under its guidance to update the risk maps of the Italian residential heritage. This extensive collaboration complied with the recent Italian code for Civil Protection, which requires a broad scientific consensus for risk assessment. During this research activity, six fragility models were developed, according to some common criteria (four for masonry buildings and two for RC buildings). These models were then implemented by the DPC for the definition of the national seismic risk. Within this context, the aim of this paper is to evaluate the risk results provided by these models, compare their features, and assess and validate their prediction capabilities. In particular, this paper shows the comparison of predicted and observed damage scenarios and consequences on building stock and the population of two seismic events, i.e. L’Aquila 2009 and Amatrice 2016. Furthermore, the paper provides some interesting damage and risk predictions at a national level. Overall, the forecasts and comparisons made in this study demonstrate the validity of the approach adopted by the DPC for the assessment of national seismic risk.
8 September 2020 in Bulletin of Earthquake Engineering
Seismic risk assessment at the territorial level is now widely recognised as essential for countries with intense seismic activity, such as Italy. Academia is called to give its contribution in order to synergically deepen the knowledge about the various components of this risk, starting from the complex evaluation of vulnerability of the built heritage. In line with this, a mechanics-based seismic fragility model for Italian residential masonry buildings was developed and presented in this paper. This model is based on the classification of the building stock in macro-typologies, defined by age of construction and number of storeys, which being information available at national level, allow simulating damage scenarios and carrying out risk analyses on a territorial scale. The model is developed on the fragility of over 500 buildings, sampled according to national representativeness criteria and analysed through the Vulnus_4.0 software. The calculated fragility functions were extended on the basis of a reference model available in the literature, which provides generic fragilities for the EMS98 vulnerability classes, thus obtaining a fragility model defined on the five EMS98 damage states. Lastly, to assess the reliability of the proposed model, this was used to simulate damage scenarios due to the 2009 L’Aquila earthquake. Overall, the comparison between model results and observed damage showed a good fit, proving the model effectiveness.
In recent years, appraisal of the condition and rehabilitation of existing bridges has become an ongoing problem for bridge owners and administrators in all developed countries. Reliable methodologies are therefore needed in the assessment and retrofit design phases, to identify the vulnerability of each bridge class. The specific problems of common arch bridge types are discussed herein, for both reinforced concrete and masonry structures, proper interventions for their static and seismic retrofitting are illustrated and several examples of applications are provided. Retrofitting is usually coupled with functional refurbishment, according to a methodological approach that takes into account bridge characteristics, state of maintenance and functional requirements, and environmental aspects connected with repair and strengthening systems
10 December 2020 in Frontiers in Built Environment
This paper presents an overview of the experimental results obtained by combined in-plane/out-of-plane (IP/OOP) tests carried out on robust clay masonry infill walls. The combined tests were carried out on eight full-scale one-bay, one-story infilled reinforced concrete (RC) frames, plus one reference RC bare frame. In four cases, the masonry walls fully fill the RC frame: two walls are made of unreinforced masonry (URM), whereas the other two are made of reinforced masonry (RM), with both vertical and horizontal reinforcement. Each pair of specimens was tested up to different levels of IP drift before carrying out the OOP tests. Four other specimens, still made of URM and RM walls, are characterized by the presence of a central opening, and in one case, the effect of a lintel is analyzed. On the basis of the tests carried out, an analytical model was developed for the analysis of the OOP behavior. It was used to calibrate IP damage degradation models based on the experimental results to define limits for the applicability of well-known flexural and arching mechanism models for the evaluation of the OOP capacity of the infill walls and to evaluate the efficiency of vertical reinforcement. In this work, the experimental campaign is presented, and the results of both experimental tests and numerical analyses are discussed.