Anna Paleczek

Ms. Anna Paleczek

Institute of Electronics, Faculty of Computer Science, Electronics and Telecommunications, AGH University of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
APAnna Paleczek
Anna Paleczek
DGDominik Grochala
Dominik Grochala
Artur RydoszArtur Rydosz
Artur Rydosz
Exhaled breath analysis has become more and more popular as a supplementary tool for medical diagnosis. However, the number of variables that have to be taken into account forces researchers to develop novel algorithms for proper data interpretation. This paper presents a system for analyzing exhaled air with the use of various sensors. Breath simulations with acetone as a diabetes biomarker were performed using the proposed e-nose system. The XGBoost algorithm for diabetes detection based on artificial breath analysis is presented. The results have shown that the designed system based on the XGBoost algorithm is highly selective for acetone, even at low concentrations. Moreover, in comparison with other commonly used algorithms, it was shown that XGBoost exhibits the highest performance and recall.

26 January 2022 in Journal of Breath Research
Verified
Journal Article
Open access
PDF file
APAnna Paleczek
Anna Paleczek
Artur RydoszArtur Rydosz
Artur Rydosz
Currently, intensive work is underway on the development of truly noninvasive medical diagnostic systems, including respiratory analysers based on the detection of biomarkers of several diseases including diabetes. In terms of diabetes, acetone is considered as a one of the potential biomarker, although is not the single one. Therefore, the selective detection is crucial. Most often, the analysers of exhaled breath are based on the utilization of several commercially available gas sensors or on specially designed and manufactured gas sensors to obtain the highest selectivity and sensitivity to diabetes biomarkers present in the exhaled air. An important part of each system are the algorithms that are trained to detect diabetes based on data obtained from sensor matrices. The prepared review of the literature showed that there are many limitations in the development of the versatile breath analyser, such as high metabolic variability between patients, but the results obtained by researchers using the algorithms described in this paper are very promising and most of them achieve over 90% accuracy in the detection of diabetes in exhaled air. This paper summarizes the results using various measurement systems, feature extraction and feature selection methods as well as algorithms such as support vector machines, k-nearest neighbours and various variations of neural networks for the detection of diabetes in patient samples and simulated artificial breath samples.

27 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ŁFŁukasz Fuśnik
Łukasz Fuśnik
BSBartłomiej Szafraniak
Bartłomiej Szafraniak
APAnna Paleczek
Anna Paleczek
DGDominik Grochala
Dominik Grochala
Artur RydoszArtur Rydosz
Artur Rydosz
Measurements of the properties of gas-sensitive materials are a subject of constant research, including continuous developments and improvements of measurement methods and, consequently, measurement set-ups. Preparation of the test set-up is a key aspect of research, and it has a significant impact on the tested sensor. This paper aims to review the current state of the art in the field of gas-sensing measurement and provide overall conclusions of how the different set-ups impact the obtained results.

26 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
APAnna Paleczek
Anna Paleczek
BSBartłomiej Szafraniak
Bartłomiej Szafraniak
ŁFŁukasz Fuśnik
Łukasz Fuśnik
ABAndrzej Brudnik
Andrzej Brudnik
DGDominik Grochala
Dominik Grochala
Artur RydoszArtur Rydosz
Artur Rydosz
Controlling environmental pollution is a burning problem for all countries more than ever. Currently, due to the increasing industrialization, the number of days when the limits of air pollutants are over the threshold levels exceeds 80–85% of the year. Therefore, cheap and effective sensors are always welcome. One idea is to combine such solutions with cars and provide real-time information about the current pollution level. However, the environmental conditions are demanding, and thus the developed sensors need to be characterized by the high 3S parameters: sensitivity, stability and selectivity. In this paper, we present the results on the heterostructure of CuO/SnOx and SnOx/CuO as a possible approach for selective NO2 detection. The developed gas sensors exhibited lower operating temperature and high response in the wide range of NO2 and in a wide range of relative humidity changes. Material characterizations and impedance spectroscopy measurements were also conducted to analyze the chemical and electrical behavior.

22 November 2024 in ACS Sensors
Verified
Journal Article
Open access
APAnna Paleczek
Anna Paleczek
JGJustyna Grochala
Justyna Grochala
DGDominik Grochala
Dominik Grochala
JSJakub Słowik
Jakub Słowik
MPMałgorzata Pihut
Małgorzata Pihut
Artur RydoszArtur Rydosz
Artur Rydosz
In this paper, the first e-nose system coupled with machine learning algorithm for noninvasive measurement of total cholesterol level based on exhaled air sample was proposed. The study was conducted with the participation of 151 people, from whom a breath sample was collected, and the level of total cholesterol was measured. The breath sample was examined using e-nose and gas sensors, such as TGS1820, TGS2620, TGS2600, MQ3, Semeatech 7e4 NO2 and 7e4 H2S, SGX_NO2, SGX_H2S, K33, AL-03P, and AL-03S. The LGBMRegressor algorithm was used to predict cholesterol level based on the breath sample. Machine learning algorithms were developed for the entire measurement range and for the norm range ≤200 mg/dL achieving MAPE 13.7% and 8%, respectively. The results show that it is possible to develop a noninvasive device to measure total cholesterol level from breath.

22 June 2022 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
DGDominik Grochala
Dominik Grochala
APAnna Paleczek
Anna Paleczek
JLJustyna Lemejda
Justyna Lemejda
MKMarcin Kajor
Marcin Kajor
MIMarek Iwaniec
Marek Iwaniec
It has been proved that dimensions of the dental arch may change as a result of growth or orthodontic treatment. The most intense transformations can be observed at young age during an occurrence of a mixed dentition period. Based on diagnostic models in a form of plaster casts there is a possibility to measure following features: overbite, overjet, the curve of Spee, arch depth, arch width and Bolton’s ratios. Nowadays computer-aided tools can provide valuable information for dentists or orthodontists and simplify analysis, diagnosis and preparation of a treatment plan. Correct organization of the dental arch in the horizontal plane can be modelled as a parabola for a mandible and as a section of the ellipse for a jaw. A developed system based on the Python programming language provides automated analysis of plaster model images. Proposed methodology includes preprocessing of provided casts’ pictures and segmentation of dental arch using methods such as image morphological operations, edge detection and active contour algorithm. In this research there were also calculated semi-ellipse and parabola fitting functions of dental arches and measured the root mean squared error relative to the original curves. Preliminary results showed 1.29 mm RMSE level for correct occlusion and 2.39 mm in case of malocclusion. Proposed methods can be used for simplifying the analysis of dental arches’ shape and monitoring of changes during orthodontic treatment.