Ingerid Reinertsen

Dr. Ingerid Reinertsen

SINTEF Digital
+1
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
AHAlessa Hering
Alessa Hering
LHLasse Hansen
Lasse Hansen
TMTony C. W. Mok
Tony C. W. Mok
ACAlbert Chi Shing Chung
Albert Chi Shing Chung
HSHanna Siebert
Hanna Siebert
MHMattias P. Heinrich
Mattias P. Heinrich
Image registration is a fundamental medical image analysis task, and a wide variety of approaches have been proposed. However, only a few studies have comprehensively compared medical image registration approaches on a wide range of clinically relevant tasks. This limits the development of registration methods, the adoption of research advances into practice, and a fair benchmark across competing approaches. The Learn2Reg challenge addresses these limitations by providing a multi-task medical image registration data set for comprehensive characterisation of deformable registration algorithms. A continuous evaluation will be possible at https:// learn2reg.grand-challenge.org. Learn2Reg covers a wide range of anatomies (brain, abdomen, and thorax), modalities (ultrasound, CT, MR), availability of annotations, as well as intra- and inter-patient registration evaluation. We established an easily accessible framework for training and validation of 3D registration methods, which enabled the compilation of results of over 65 individual method submissions from more than 20 unique teams. We used a complementary set of metrics, including robustness, accuracy, plausibility, and runtime, enabling unique insight into the current state-of-the-art of medical image registration. This paper describes datasets, tasks, evaluation methods and results of the challenge, as well as results of further analysis of transferability to new datasets, the importance of label supervision, and resulting bias. While no single approach worked best across all tasks, many methodological aspects could be identified that push the performance of medical image registration to new state-of-the-art performance. Furthermore, we demystified the common belief that conventional registration methods have to be much slower than deep-learning-based methods.

5 March 2013 in Acta Neurochirurgica
Verified
Journal Article
Open access
PDF file
TSTormod Selbekk
Tormod Selbekk
AJAsgeir Jakola
Asgeir Jakola
OSOle Solheim
Ole Solheim
TJTonni Franke Johansen
Tonni Franke Johansen
FLFrank Lindseth
Frank Lindseth
GUGeirmund Unsgård
Geirmund Unsgård
Background Intraoperative ultrasound imaging is used in brain tumor surgery to identify tumor remnants. The ultrasound images may in some cases be more difficult to interpret in the later stages of the operation than in the beginning of the operation. The aim of this paper is to explain the causes of surgically induced ultrasound artefacts and how they can be recognized and reduced. Methods The theoretical reasons for artefacts are addressed and the impact of surgery is discussed. Different setups for ultrasound acquisition and different acoustic coupling fluids to fill up the resection cavity are evaluated with respect to improved image quality. Results The enhancement artefact caused by differences in attenuation of the resection cavity fluid and the surrounding brain is the most dominating surgically induced ultrasound artefact. The influence of the artefact may be reduced by inserting ultrasound probes with small footprint into the resection cavity for a close-up view of the areas with suspected tumor remnants. A novel acoustic coupling fluid developed for use during ultrasound imaging in brain tumor surgery has the potential to reduce surgically induced ultrasound artefacts to a minimum. Conclusions Surgeons should be aware of artefacts in ultrasound images that may occur during brain tumor surgery. Techniques to identify and reduce image artefacts are useful and should be known to users of ultrasound in brain tumor surgery.

16 May 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
YXYiming Xiao
Yiming Xiao
MFMaryse Fortin
Maryse Fortin
GUGeirmund Unsgård
Geirmund Unsgård
HRHassan Rivaz
Hassan Rivaz
IRIngerid Reinertsen
Ingerid Reinertsen

26 September 2015 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
CAChristian Askeland
Christian Askeland
OSOle Vegard Solberg
Ole Vegard Solberg
JBJanne Beate Lervik Bakeng
Janne Beate Lervik Bakeng
IRIngerid Reinertsen
Ingerid Reinertsen
GTGeir Arne Tangen
Geir Arne Tangen
FLFrank Lindseth
Frank Lindseth
Purpose CustusX is an image-guided therapy (IGT) research platform dedicated to intraoperative navigation and ultrasound imaging. In this paper, we present CustusX as a robust, accurate, and extensible platform with full access to data and algorithms and show examples of application in technological and clinical IGT research. Methods CustusX has been developed continuously for more than 15 years based on requirements from clinical and technological researchers within the framework of a well-defined software quality process. The platform was designed as a layered architecture with plugins based on the CTK/OSGi framework, a superbuild that manages dependencies and features supporting the IGT workflow. We describe the use of the system in several different clinical settings and characterize major aspects of the system such as accuracy, frame rate, and latency. Results The validation experiments show a navigation system accuracy of \(<\)1.1 mm, a frame rate of 20 fps, and latency of 285 ms for a typical setup. The current platform is extensible, user-friendly and has a streamlined architecture and quality process. CustusX has successfully been used for IGT research in neurosurgery, laparoscopic surgery, vascular surgery, and bronchoscopy. Conclusions CustusX is now a mature research platform for intraoperative navigation and ultrasound imaging and is ready for use by the IGT research community. CustusX is open-source and freely available at http://www.custusx.org.

13 August 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YXYiming Xiao
Yiming Xiao
HRHassan Rivaz
Hassan Rivaz
MCMatthieu Chabanas
Matthieu Chabanas
MFMaryse Fortin
Maryse Fortin
IMInes Prata Machado
Ines Prata Machado
IRIngerid Reinertsen
Ingerid Reinertsen
In brain tumor surgery, the quality and safety of the procedure can be impacted by intra-operative tissue deformation, called brain shift. Brain shift can move the surgical targets and other vital structures such as blood vessels, thus invalidating the pre-surgical plan. Intra-operative ultrasound (iUS) is a convenient and cost-effective imaging tool to track brain shift and tumor resection. Accurate image registration techniques that update pre-surgical MRI based on iUS are crucial but challenging. The MICCAI Challenge 2018 for Correction of Brain shift with Intra-Operative UltraSound (CuRIOUS2018) provided a public platform to benchmark MRI-iUS registration algorithms on newly released clinical datasets. In this work, we present the data, setup, evaluation, and results of CuRIOUS 2018, which received 6 fully automated algorithms from leading academic and industrial research groups. All algorithms were first trained with the public RESECT database, and then ranked based on a test dataset of 10 additional cases with identical data curation and annotation protocols as the RESECT database. The article compares the results of all participating teams and discusses the insights gained from the challenge, as well as future work.

1 August 2007 in Medical Image Analysis
Verified
Journal Article
Closed access
IRIngerid Reinertsen
Ingerid Reinertsen
MDM. Descoteaux
M. Descoteaux
KSK. Siddiqi
K. Siddiqi
DCD.L. Collins
D.L. Collins