Purpose: The study aimed to establish the test–retest reliability and convergent validity of PlayerLoad™ (triaxial-accelerometer data) during a standardized bout of treadmill running.Methods: Forty-four team-sport players performed 2 standardized incremental treadmill running tests (7–16 km/h) 7 d apart. Players’ oxygen uptake (VO2; n = 20), heart rate (n = 44), and triaxialaccelerometer data (PlayerLoad; n = 44) measured at both the scapulae and at the center of mass (COM), were recorded. Accelerometer data from the individual component planes of PlayerLoad (anteroposterior [PLAP], mediolateral [PLML], and vertical [PLV]) were also examined.Results: Moderate to high test–retest reliability was observed for PlayerLoad and its individual planes (ICC .80–.97, CV 4.2–14.8%) at both unit locations. PlayerLoad was significantly higher at COM vs scapulae (223.4 ± 42.6 vs 185.5 ± 26.3 arbitrary units; P = .001). The percentage contributions of individual planes to PlayerLoad were higher for PLML at the COM (scapulae 20.4% ± 3.8%, COM 26.5% ± 4.9%; P = .001) but lower for PLV (scapulae 55.7% ± 5.3%, COM 49.5% ± 6.9%; P = .001). Between-subjects correlations between PlayerLoad and VO2, and between PlayerLoad and heart rate were trivial to moderate (r = –.43 to .33), whereas within-subject correlations were nearly perfect (r = .92–.98).Conclusions: PlayerLoad had a moderate to high degree of test–retest reliability and demonstrated convergent validity with measures of exercise intensity on an individual basis. However, caution should be applied in making between-athletes contrasts in loading and when using recordings from the scapulae to identify lower-limb movement patterns.
In this study, criteria are used to identify whether a subject has elicited maximal oxygen uptake. We evaluated the validity of traditional maximal oxygen uptake criteria and propose a novel set of criteria. Twenty athletes completed a maximal oxygen uptake test, consisting of an incremental phase and a subsequent supramaximal phase to exhaustion (verification phase). Traditional and novel maximal oxygen uptake criteria were evaluated. Novel criteria were: oxygen uptake plateau defined as the difference between modelled and actual maximal oxygen uptake >50% of the regression slope of the individual oxygen uptake–workrate relationship; as in the first criterion, but for maximal verification oxygen uptake; and a difference of ≤4 beats·min–1 between maximal heart rate values in the 2 phases. Satisfying the traditional oxygen uptake plateau criterion was largely an artefact of the between-subject variation in the oxygen uptake–workrate relationship. Secondary criteria, supposedly an indicator of maximal effort, were often satisfied long before volitional exhaustion, even at intensities as low as 61% maximal oxygen uptake. No significant mean differences were observed between the incremental and verification phases for oxygen uptake (t = 0.4; p = 0.7) or heart rate (t = 0.8; p = 0.5). The novel oxygen uptake plateau criterion, maximal oxygen uptake verification criterion, and maximal heart rate verification criterion were satisfied by 17, 18, and 18 subjects, respectively. The small individual absolute differences in oxygen uptake between incremental and verification phases observed in most subjects provided additional confidence that maximal oxygen uptake was elicited. Current maximal oxygen uptake criteria were not valid and novel criteria should be further explored.