We have developed a proportional-integral-derivative controller allowing the closed-loop coadministration of propofol and remifentanil, guided by a Bispectral Index (BIS) monitor, during induction and maintenance of general anesthesia. The controller was compared with manual target-controlled infusion. In a multicenter study, 196 surgical patients were randomly assigned to dual closed-loop or manual administration of propofol and remifentanil. Comparison between groups was evaluated by calculating a global score that characterized the overall performance of the controller including the percentage of adequate anesthesia, defined as BIS between 40 and 60, the median absolute performance error, and wobble. Secondary outcomes included occurrence of burst suppression ratio, time to tracheal extubation, and drug consumption. Eighty-three patients assigned to dual-loop control and 84 patients assigned to manual control completed the study. The global score and the percentage of time with BIS between 40 and 60 were better in the dual-loop group (26 ± 11 vs 43 ± 40, P < 0.0001; 82% ± 12% vs 71% ± 19%, P < 0.0001). Overshoot (BIS 60), and burst suppression ratio were all significantly less common in the dual-loop group. Modifications to the propofol and remifentanil infusions were more frequent, and adjustments smaller in the dual-loop group. Remifentanil consumption was greater (0.22 ± 0.07 vs 0.16 ± 0.07 μg · kg(-1) · min(-1); P < 0.0001) and the speed to tracheal extubation was shorter (10 ± 4 vs 11 ± 5 minutes; P = 0.02) in the dual-loop group. The controller allows the automated delivery of propofol and remifentanil and maintains BIS values in predetermined boundaries during general anesthesia better than manual administration.
Background: This report describes a closed-loop titration of propofol target control infusion based on a proportional-differential algorithm guided by the Bispectral Index (BIS) allowing induction and maintenance of general anesthesia and compares this to manual propofol target control infusion. Methods: One hundred sixty-four patients scheduled to undergo elective minor or major surgery were prospectively randomized in a multicenter study into the closed-loop (n = 83) or manual target control infusion group (n = 81). The goal was to reach a BIS target of 50 during induction and to maintain it between 40 and 60 during maintenance. For both groups, remifentanil target control infusion was adjusted manually, and ventilation was without nitrous oxide. Results: Closed-loop control was able to provide anesthesia induction and maintenance for all patients. During induction, propofol consumption was lower in the closed-loop group (1.4 +/- 0.5 vs. 1.8 +/- 0.6 mg/kg; P < 0.0001), but the duration was longer (320 +/- 125 vs. 271 +/- 120 s; P < 0.0002). Adequate anesthesia maintenance, defined as the BIS in the range of 40-60, was significantly higher in the closed-loop group (89 +/- 9 vs. 70 +/- 21%; P < 0.0001), with a decrease of the occurrence of BIS less than 40 (8 +/- 8 vs. 26 +/- 22%; P < 0.0001). Time from discontinuation of propofol infusion to tracheal extubation was shorter in the closed-loop group (7 +/- 4 vs. 10 +/- 7 min; P < 0.017). Unwanted somatic events and hemodynamic instability were similar. Conclusion: Automatic control of consciousness using the BIS is clinically feasible and outperforms manual control.
Background: The optimal dose of tranexamic acid (TA) is still an issue. The authors compared two doses of TA during cardiac surgery in a multicenter, double-blinded, randomized study. Methods: Patients were stratified according to transfusion risk, then randomized to two TA doses: 10 mg/kg bolus followed by 1 mg·kg−1·h−1 infusion (low dose) until the end of surgery or 30 mg/kg bolus followed by 16 mg·kg−1·h−1 infusion (high dose). The primary endpoint was the incidence of blood product transfusion up to day 7. Secondary ones were incidences of transfusion for each type of blood product and amounts transfused, blood loss, repeat surgery, TA-related adverse events, and mortality. Results: The low-dose group comprised 284 patients and the high-dose one 285. The primary endpoint was not significantly different between TA doses (63% for low dose vs. 60% for high dose; P = 0.3). With the high dose, a lower incidence of frozen plasma (18 vs. 26%; P = 0.03) and platelet concentrate (15 vs. 23%; P = 0.02) transfusions, lower amounts of blood products (2.5 ± 0.38 vs. 4.1 ± 0.39; P = 0.02), fresh frozen plasma (0.49 ± 0.14 vs.1.07 ± 0.14; P = 0.02), and platelet concentrates transfused (0.50 ± 0.15 vs. 1.13 ± 0.15; P = 0.02), lower blood loss (590 ± 50.4 vs. 820 ± 50.7; P = 0.01), and less repeat surgery (2.5 vs. 6%; P = 0.01) were observed. These results are more marked in patients with a high risk for transfusion. Conclusions: A high dose of TA does not reduce incidence of blood product transfusion up to day 7, but is more effective than a low dose to decrease transfusion needs, blood loss, and repeat surgery.
Measurement of blood hemoglobin (Hb) concentration is a routine procedure. Using a non-invasive point-of-care device reduces pain and discomfort for the patient and allows time saving in patient care. The aims of the present study were to assess the concordance of Hb levels obtained non-invasively with the Pronto-7 monitor (version 2.1.9, Masimo Corporation, Irvine, USA) or with the NBM-200MP monitor (Orsense, Nes Ziona, Israel) and the values obtained from the usual colorimetric method using blood samples and to determine the source of discordance. We conducted two consecutive prospective open trials enrolling patients presenting in the emergency department of a university hospital. The first was designed to assess Pronto-7™ and the second NBM-200MP™. In each study, the main outcome measure was the agreement between both methods. Independent factors associated with the bias were determined using multiple linear regression. Three hundred patients were prospectively enrolled in each study. For Pronto-7™, the absolute mean difference was 0.56 g.L−1 (95% confidence interval [CI] 0.41 to 0.69) with an upper agreement limit at 2.94 g.L−1 (95% CI [2.70;3.19]), a lower agreement limit at -1.84 g.L−1 (95% CI [-2.08;-1.58]) and an intra-class correlation coefficient at 0.80 (95% CI [0.74;0.84]). The corresponding values for the NBM-200MP™ were 0.21 [0.02;0.39], 3.42 [3.10;3.74], -3.01 [-3.32;-2.69] and 0.69 [0.62;0.75]. Multivariate analysis showed that age and laboratory values of hemoglobin were independently associated with the bias when using Pronto-7™, while perfusion index and laboratory value of hemoglobin were independently associated with the bias when using NBM-200MP™. Despite a relatively limited bias in both cases, the large limits of agreement found in both cases render the clinical usefulness of such devices debatable. For both devices, the bias is independently and inversely associated with the true value of hemoglobin. ClinicalTrials.gov NCT01321580 NCT01321593