Piotr Marcinowski

Dr. Piotr Marcinowski

Warsaw University of Technology, Faculty of Building Services, Hydro and Environmental Engineering Warsaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2013 in Environmental Technology
Verified
Journal Article
Closed access
JNJeremi Naumczyk
Jeremi Naumczyk
Jan BogackiJan Bogacki
Jan Bogacki
PMPiotr Marcinowski
Piotr Marcinowski
PKPaweł Kowalik
Paweł Kowalik
In this study, the treatment process of three cosmetic wastewater types has been investigated. Coagulation allowed to achieve chemical oxygen demand (COD) removal of 74.6%, 37.7% and 74.0% for samples A (Al2(SO4)3), B (Brentafloc F3) and C (PAX 16), respectively. The Fenton process proved to be effective as well – COD removal was equal to 75.1%, 44.7% and 68.1%, respectively. Coagulation with FeCl3 and the subsequent photo-Fenton process resulted in the best values of final COD removal equal to 92.4%, 62.8% and 90.2%. In case of the Fenton process, after coagulation these values were equal to 74.9%, 50.1% and 84.8%, while in case of the H2O2/UV process, the obtained COD removal was 83.8%, 36.2% and 80.9%. High value of COD removal in the Fenton process carried out for A and C wastewater samples was caused by a significant contribution of the final neutralization/coagulation. Very small effect of the oxidation reaction in the Fenton process in case of sample A resulting from the presence of antioxidants, ‘OH radical scavengers’ in the wastewater.

28 March 2023 in MRS Bulletin
Verified
Journal Article
Open access
PDF file
DBDominika Bury
Dominika Bury
MJMichał Jakubczak
Michał Jakubczak
KRKumar Rajiv
Kumar Rajiv
DŚDominika Ścieżyńska
Dominika Ścieżyńska
Jan BogackiJan Bogacki
Jan Bogacki
Agnieszka JastrzębskaAgnieszka Jastrzębska
Agnieszka Jastrzębska
Rapid global industrialization constantly impacts the environment by discharging pollutants. Therefore, various materials are currently being investigated for environmental applications, including two-dimensional (2D) MXenes. Herein, we focus on MXene-enabled technologies for removing inorganic and organic contaminants present in gaseous and liquid forms, especially organic dyes, pharmaceuticals, and solid pollutants. We foresee a considerable potential for MXene-enabled technologies to remove heavy ions and radionuclides and recover precious elements. We show that MXenes could efficiently inactivate microorganisms without harming the environment. Finally, we discuss the associated opportunities and challenges in MXenes’ surface chemistry, semiconducting activity, interfacial effects, adsorption, and photocatalysis. Altogether, this article showcases outstanding opportunities for MXenes in the rapidly growing field of environmental applications. Graphical abstract

19 November 2018 in Processes
Verified
Journal Article
Open access
PDF file
Jan BogackiJan Bogacki
Jan Bogacki
PMPiotr Marcinowski
Piotr Marcinowski
MMMaciej Majewski
Maciej Majewski
Jarosław ZawadzkiJarosław Zawadzki
Jarosław Zawadzki
SSSridhar Sivakumar
Sridhar Sivakumar
Fossil fuel combustion is a serious environmental problem. Significant quantities of flue gasses and wastewater, requiring further treatment, are produced. This article compares three wet flue gas desulfurization (FGD) wastewater treatment methods: coagulation with precipitation using iron(III) ions—recommended by the European Union as the best available technique (BAT)—and two alternative advanced oxidation processes (Fe2+/H2O2 and Fe0/H2O2). Both oxidation processes that were used met the technical FGD wastewater treatment requirements of the BAT. The best treatment effects, expressed as pollutants’ removal, were obtained for the Fe2+/H2O2 process for 150/300 mg/L reagent doses. It allows effective removal of boron up to 212 mg/L and heavy metals up to below the detection limit <0.010 mg/L for Pb and <0.005 mg/L for Cu. Therefore, the Fe2+/H2O2 process could be an option for FGD wastewater treatment as an alternative to the BAT recommended iron(III)-based coagulation with precipitation. Additionally, an analysis of variance was applied to check the significance of the two independent variables and their interactions. Statistical analysis confirmed high efficiency and applicability of treatment process.

26 September 2012 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
JNJeremi Naumczyk
Jeremi Naumczyk
IPIzabela Prokurat
Izabela Prokurat
PMPiotr Marcinowski
Piotr Marcinowski
Advanced oxidation processes (AOPs) such as H2O2/UV, O3/H2O2, modified Fenton, and modified photo-Fenton processes have been investigated in terms of the treatment of landfill leachate with ratio of BOD5/COD in the range of 0.22 to 0.24. The modification of Fenton and photo-Fenton processes consisted in the inclusion of precipitation and separation of humic substances at pH 3. Due to the precipitation, the value of COD decreased by 39% and BOD5by 7.1%. The modification of the processes allowed us to improve the efficiency and to decrease the doses of reagents necessary to continue the process. Modified photo-Fenton process proved to be the most effective (92.7% COD removal) of all processes investigated. Additionally, modified-Fenton process was much more effective than the other two processes when compared up to 120 min, while after longer times it gave the least satisfactory results. After 30 min of modified-Fenton process BOD5/COD ratio increased to 0.43. The parameter referred to as “efficiency of oxidants” was used to estimate the efficiency of all the processes—its value varied from 178 to 239%. Various substances including phthalates, hydrocarbons, silanes, and siloxanes were identified in raw and treated leachate.

23 October 2020 in Processes
Verified
Journal Article
Open access
PDF file
PMPiotr Marcinowski
Piotr Marcinowski
DBDominika Bury
Dominika Bury
MKMonika Krupa
Monika Krupa
DŚDominika Ścieżyńska
Dominika Ścieżyńska
PPPrasanth Prabhu
Prasanth Prabhu
Jan BogackiJan Bogacki
Jan Bogacki
Wastewater from a cosmetic factory, with an initial total organic carbon (TOC) of 146.4 mg/L, was treated with Fe2O3/Fe0/H2O2, Fe3O4/Fe0/H2O2, light/Fe2O3/Fe0/H2O2, and light/Fe3O4/Fe0/H2O2 processes. The light-supported processes were more effective than the lightless processes. The fastest TOC removal was observed during the first 15 min of the process. Out of the four tested kinetic models, the best fit was obtained for the modified second-order reaction with respect to the TOC value. The best treatment efficiency was obtained for the light/Fe3O4/Fe0/H2O2 process with 250/750 mg/L Fe3O4/Fe0 reagent doses, a 1:1 hydrogen peroxide to Chemical Oxygen Demand (H2O2/COD) mass ratio, and a 120 min process time. These conditions allowed 75.7% TOC removal to a final TOC of 35.52 mg/L and 90.5% total nitrogen removal to a final content of 4.9 mg/L. The five-day Biochemical Oxygen Demand to Chemical Oxygen Demand (BOD5/COD) ratio was increased slightly from 0.124 to 0.161. Application of Head Space Solid-Phase Microextraction Gas Chromatography Mass Spectrometry (HS-SPME-GC-MS) analysis allows for the detection and identification of 23 compounds contained in the raw wastewater. The identified compounds were eliminated during the applied process. The HS-SPME-GC-MS results confirmed the high efficiency of the treatment processes.

19 August 2014 in Journal of Environmental Science and Health, Part A
Verified
Journal Article
Closed access
PMPiotr Marcinowski
Piotr Marcinowski
Jan BogackiJan Bogacki
Jan Bogacki
JNJeremi H. Naumczyk
Jeremi H. Naumczyk
Advanced Oxidation Processes (AOPs), such as the Fenton, photo-Fenton and H2O2/UV processes, have been investigated for the treatment of cosmetic wastewaters that were previously coagulated by FeCl3. The Photo-Fenton process at pH 3.0 with 1000/100 mg L−1 H2O2/Fe2+ was the most effective (74.0% Chemical Oxygen Demand (COD) removal). The Fenton process with 1200/500 mg L−1 H2O2/Fe2+ achieved a COD removal of 72.0%, and the H2O2/UV process achieved a COD removal of 47.0%. Spreading the H2O2 doses over time to obtain optimal conditions did not improve COD removal. The kinetics of the Fenton and photo-Fenton processes may be described by the following equation: d[COD]/dt = -a[COD] tm (t represents time and a and m are constants). The rate of COD removal by the H2O2/UV process may be described by a second-order reaction equation. Head Space, Solid-Phase MicroExtraction, Gas Chromatography and Mass Spectrometry (HS-SPME-GC-MS) were used to identify 48 substances in precoagulated wastewater. Among these substances, 26 were fragrances. Under optimal AOP conditions, over 99% of the identified substances were removed in 120 min.