Shih-Hsing Yang

Dr. Shih-Hsing Yang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
HTHui-Yun Tseng
Hui-Yun Tseng
SYShih-Hsing Yang
Shih-Hsing Yang
HCHan-Sun Chiang
Han-Sun Chiang
Background: Measuring the fraction of inspired oxygen (FiO2) is challenging in spontaneously breathing patients with impaired respiratory mechanics during low-flow nasal cannula. Our study investigates the FiO2 with varied tidal volume (VT) and respiratory rate (RR) among different lung mechanics and provides equations to estimate the FiO2. Methods: Two training and test lungs were used in this study, and the three lung mechanics (normal (R5/C60), restrictive (R20/C80), obstructive (R5/C40)) were designed. Spontaneous breathing with VT (300, 500, and 700 mL) and RR (10, 20, and 30 breaths/min) was simulated. The flow rate of the nasal cannula was set to 1, 3, and 5 L per minute (LPM), and the FiO2 was measured at the carina. Results: The lowest and highest FiO2 were evident during high (700 mL) and low VT (300 mL), respectively, among normal, restrictive, and obstructive lung models. As RR increases, this decreases the FiO2. However, we found that VT and oxygen flow rate are the principal factors influencing measured FiO2 by multiple linear regression analysis. Conclusions: Our data suggest that the actual FiO2 is never as high in spontaneously breathing patients as that estimated. VT and oxygen flow rate had a substantial impact on the FiO2.

7 March 2025 in The Clinical Respiratory Journal
Verified
Journal Article
Open access
KCKe-Yun Chao
Ke-Yun Chao
WLWEI-LUN LIU
WEI-LUN LIU
CCChao‐Yu Chen
Chao‐Yu Chen
CSChia‐Hui Su
Chia‐Hui Su
SYShih-Hsing Yang
Shih-Hsing Yang
YHYu‐Tzu Huang
Yu‐Tzu Huang
Introduction: Mechanical ventilation is a significant risk factor for developing ventilator‐associated pneumonia. Although silver‐coated endotracheal tubes have been shown to reduce the bacterial burden, the efficacy of silver‐based ion additive ventilator circuits in reducing bacterial colonization remains unclear.Methods: This single‐site, randomized controlled trial compared the incidence of bacterial contamination between a silver‐additive ventilator circuit and a ventilator circuit that did not have a silver additive. Bacterial samples were collected from the inspiratory limb and Y‐adaptor of the circuit and analyzed using culture and identification methods.Results: Bacterial growth was observed in all samples from the control group and in 93.7% and 81.2% of inspiratory limb and Y‐adaptor samples, respectively, from the study group. The colony counts in the inspiratory limb samples were significantly different between the groups, with a higher proportion of undesirable colony counts in the control group compared with the study group. No significant difference between the groups was observed in the colony counts in the Y‐adaptor samples.Conclusion: The use of a silver‐additive ventilator circuit may reduce bacterial circuit colonization. However, further research with larger sample sizes and more diverse patient populations is necessary to confirm these findings.Trial Registration: ClinicalTrial.gov: NCT04927806

23 September 2025 in Journal of the Formosan Medical Association
Verified
Journal Article
Open access
SLShwu Jen Lin
Shwu Jen Lin
YKYao-Wen Kuo
Yao-Wen Kuo
HWHuey Dong Wu
Huey Dong Wu
SYShih-Hsing Yang
Shih-Hsing Yang
Purpose: Home mechanical ventilation offers significant benefits, but hospital readmissions remain a challenge, with rates as high as 20-40 % and associated mortality. While some studies have investigated risk factors for readmission, pre-discharge factors influencing unplanned readmissions in this population remain unclear. This study aimed to identify pre-discharge factors associated with unplanned hospital readmissions in home-ventilated patients. A 60-month retrospective cohort study was conducted, including patients receiving home mechanical ventilation. Demographic, respiratory, physiological, and laboratory parameters near discharge were collected. Readmissions were categorized as occurring within 30 days and beyond to identify pre-discharge factors associated with unplanned hospital readmissions. Among a cohort of 6925 mechanically ventilated patients, 913 were readmitted. Of these, 127 were unplanned readmissions, with an average age of 70 years, predominantly female (68 subjects), and 33.1 % occurred within 30 days post-discharge. Logistic regression analysis identified cardiovascular disease, maximum inspiratory pressure, and low hemoglobin levels as significant predictors of early unplanned readmissions within 30 days. Unplanned hospital readmissions pose a considerable challenge for home-ventilated patients, particularly within the first 30 days post-discharge. Pre-discharge factors, including cardiovascular disease, low inspiratory muscle performance as assessed by PImax, and low hemoglobin levels, are key risk factors. Addressing these factors during discharge planning is crucial to reducing early readmissions and improving patient outcomes and resource allocation in healthcare.

16 April 2021 in SIMULATION
Verified
Journal Article
Open access
PDF file
FJFang Jung
Fang Jung
SCShang-Shing P Chou
Shang-Shing P Chou
SYShih-Hsing Yang
Shih-Hsing Yang
JLJau-Chen Lin
Jau-Chen Lin
GJGuey-Mei Jow
Guey-Mei Jow
A closed suction system is used to remove endotracheal secretions without interrupting the patient’s ventilation. Closed suctioning may reduce adverse effects associated with suctioning with, for example, decreased clinical signs of hypoxemia and limited environmental, personnel, and patient contamination. However, it is not clear whether ventilation is maintained during the procedure. We aimed to determine the effects of endotracheal tube (ETT) size, suction catheter (SC) size, and SC length in the ETT on ventilation parameters measured during suction. Suction was performed on a test lung, ventilated with either volume-controlled continuous mandatory ventilation (VC-CMV) or pressure-controlled continuous mandatory ventilation (PC-CMV) using ETT sizes of 6.0–8.5 mm paired with SC sizes of 8–16 French gauge (Fr = 0.33 mm). Airway resistance ( Raw), peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), and expiratory minute volume ( Vexp) were recorded for each ventilation episode by a HAMILTON-G5 ventilator. Here, Raw was considerably increased by insertion of the SC into the ETT. This Raw effect altered the PIP and Vexp. PIP was increased in VC-CMV because the ventilation area of the ETT was reduced, and Vexp was decreased in PC-CMV in relation to the size of the SC. PEEP decreased with application of the 16 Fr SC and 30 L/min flow rate in VC-CMV. We conclude that airway pressure and minute volume are not maintained during closed endotracheal suctioning with VC-CMV and PC-CMV, respectively. The degree of interference to ventilation is affected through selection of appropriate SC size and ventilation settings.

1 June 2017 in Journal of Critical Care
Verified
Journal Article
Closed access
CPChung-Kan Peng
Chung-Kan Peng
SWShu-Fen Wu
Shu-Fen Wu
SYShih-Hsing Yang
Shih-Hsing Yang
CHChuan-Fa Hsieh
Chuan-Fa Hsieh
CHChung-Chih Huang
Chung-Chih Huang
CWChin-Pyng Wu
Chin-Pyng Wu

6 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FJFang Jung
Fang Jung
SCShang-Shing P. Chou
Shang-Shing P. Chou
SYShih-Hsing Yang
Shih-Hsing Yang
JLJau-Chen Lin
Jau-Chen Lin
GJGuey-Mei Jow
Guey-Mei Jow
A closed suctioning system (CSS) in patients with coronavirus disease 2019 (COVID-19) prevents spraying respiratory secretions into the environment during suction. However, it is not clear whether ventilation is maintained during the suction procedure, especially in patients with compromised pulmonary mechanics. This paper determines the effects of endotracheal tube (ETT) size, suction catheter size, and two lung mechanics (resistance and compliance) on ventilator-related parameters measured during suction. Suction was performed on an adult training lung, ventilated with either volume-controlled (VC-CMV) or pressure-controlled mandatory ventilation (PC-CMV), using ETT sizes of 6.5–8.0 mm paired with suction catheter sizes of 8–14 French (Fr). Peak inspiratory pressure (PIP) increased by 50% when the ETT’s ventilation area was less than 25 mm2 in size, especially in patients with high airway resistance ventilated with VC-CMV. Positive end-expiratory pressure (PEEP) levels significantly decreased when using 14 Fr SC during VC-CMV and fewer effects during PC-CMV. Change of expiratory minute volume increased with higher outer diameter of suction catheters and decreased with severe lung compliance during PC-CMV. The change in ventilator-related parameters were intently monitored in the patient whose pulmonary mechanic was compromised through the CSS endotracheal tube suctioning procedures in clinical airway management.