Anurag Chauhan*

Dr. Anurag Chauhan*


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
ACAnurag Chauhan*
Anurag Chauhan*
SUSubho Upadhyay
Subho Upadhyay
MKMohd Tauseef Khan
Mohd Tauseef Khan
SHS.M. Suhail Hussain
S.M. Suhail Hussain
Taha Selim UstunTaha Selim Ustun
Taha Selim Ustun
In the current scenario, sustainable power generation received greater attention due to the concerns of global warming and climate change. In the present paper, a Solar Photovoltaic/Diesel Generator/ Battery-based hybrid system has been considered to meet the electrical energy demand of a remote location of India. The cost of the energy of hybrid system is minimized using a Biogeography-based Optimization (BBO) algorithm under the constraints of power reliability, carbon emission and renewable energy fraction. Load following and cycle charging strategies have been considered in order to investigate the performance analysis of the proposed hybrid system. Further, different component combinations of specifications available on the market are presented for detail analysis. The minimum cost of energy of the proposed hybrid system is obtained as 0.225 $/kWh.

5 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
ASAshish Srivastava
Ashish Srivastava
ACAnurag Chauhan*
Anurag Chauhan*
ATAnurag Tripathi
Anurag Tripathi
In the present context, the asymmetrical multilevel inverter (AMLI) with minimal switches is extensively used to achieve high power quality across a load. The conventional inverter suffers from the disadvantages of large system components, low efficiency, high THD, high losses, etc. The asymmetrical multilevel inverter therefore offers an appropriate alternative to address the key issues of conventional inverters. The present paper aims to analyze the performance comparison of the proposed 15-level AMLI structure with different switching techniques, i.e., NLC, SHEPWM and SPWM. Moreover, loss analysis of the considered AMLI has been performed for different switching techniques. Furthermore, different performance parameters such as conduction losses, switching losses, total losses, THD, efficiency and power delivery of the inverter have been evaluated. It has been observed that the considered inverter topology offers the superior performance with the SHEPWM modulation technique at a modulation index of 0.8. Finally, hardware arrangement of the inverter has also been developed in the laboratory with a real-time Opal-RT 4510 simulator to verify the accuracy of simulation results.

2 December 2021
Verified
Book Chapter
Closed access
PDF file
ACAnurag Chauhan*
Anurag Chauhan*
ASAshish Srivastava
Ashish Srivastava
MKMohd Tauseef Khan
Mohd Tauseef Khan
AAAltaf Alam
Altaf Alam
SUSubho Upadhyay
Subho Upadhyay