Tadeusz Pustelny

Prof. Tadeusz Pustelny

Department of Optoelectronics, Silesian University of Technology, 2 Krzywoustego St., 44-100 Gliwice, Poland

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2018 in Materials
Verified
Journal Article
Open access
PDF file
RMRoksana Muzyka
Roksana Muzyka
SDSabina Drewniak
Sabina Drewniak
Tadeusz PustelnyTadeusz Pustelny
Tadeusz Pustelny
MCMaciej Chrubasik
Maciej Chrubasik
GGGrażyna Gryglewicz
Grażyna Gryglewicz
In this paper, the influences of the graphite precursor and the oxidation method on the resulting reduced graphene oxide (especially its composition and morphology) are shown. Three types of graphite were used to prepare samples for analysis, and each of the precursors was oxidized by two different methods (all samples were reduced by the same method of thermal reduction). Each obtained graphite oxide and reduced graphene oxide was analysed by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy (RS).

15 January 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SDSabina Drewniak
Sabina Drewniak
RMRoksana Muzyka
Roksana Muzyka
ASAgnieszka Stolarczyk
Agnieszka Stolarczyk
Tadeusz PustelnyTadeusz Pustelny
Tadeusz Pustelny
MKMichalina Kotyczka-Morańska
Michalina Kotyczka-Morańska
MSMaciej Setkiewicz
Maciej Setkiewicz
The paper presents the results of investigations on resistance structures based on graphite oxide (GRO) and graphene oxide (rGO). The subject matter of the investigations was thaw the sensitivity of the tested structures was affected by hydrogen, nitrogen dioxide and carbon dioxide. The experiments were performed at a temperature range from 30 °C to 150 °C in two carrier gases: nitrogen and synthetic air. The measurements were also aimed at characterization of the graphite oxide and graphene oxide. In our measurements we used (among others) techniques such as: Atomic Force Microscopy (AFM); Scanning Electron Microscopy (SEM); Raman Spectroscopy (RS); Fourier Transform Infrared Spectroscopy (FT-IR) and X-ray Photoelectron Microscopy (XPS). The data resulting from the characterizations of graphite oxide and graphene oxide have made it possible to interpret the obtained results from the point of view of physicochemical changes occurring in these structures.

22 April 2015 in Sensors
Verified
Journal Article
Open access
PDF file
Marcin ProcekMarcin Procek
Marcin Procek
ASAgnieszka Stolarczyk
Agnieszka Stolarczyk
Tadeusz PustelnyTadeusz Pustelny
Tadeusz Pustelny
EMErwin Maciak
Erwin Maciak
The paper deals with investigations concerning the construction of sensors based on a quartz crystal microbalance (QCM) containing a TiO2 nanostructures sensor layer. A chemical method of synthesizing these nanostructures is presented. The prepared prototype of the QCM sensing system, as well as the results of tests for detecting low NO2 concentrations in an atmosphere of synthetic air have been described. The constructed NO2 sensors operate at room temperature, which is a great advantage, because resistance sensors based on wide gap semiconductors often require much higher operation temperatures, sometimes as high as 500 °C. The sensors constructed by the authors can be used, among other applications, in medical and chemical diagnostics, and also for the purpose of detecting explosive vapours. Reactions of the sensor to nitroglycerine vapours are presented as an example of its application. The influence of humidity on the operation of the sensor was studied.

15 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SDSabina Drewniak
Sabina Drewniak
ŁDŁukasz Drewniak
Łukasz Drewniak
Tadeusz PustelnyTadeusz Pustelny
Tadeusz Pustelny
The sensitive detection of harmful gases, in particular nitrogen dioxide, is very important for our health and environment protection. Therefore, many papers on sensor materials used for NO2 detection have been published in recent years. Materials based on graphene and reduced graphene oxide deserve special attention, as they exhibit excellent sensor properties compared to the other materials. In this paper, we present the most recent advances in rGO hybrid materials developed for NO2 detection. We discuss their properties and, in particular, the mechanism of their interaction with NO2. We also present current problems occuring in this field.

11 October 2017 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Marcin ProcekMarcin Procek
Marcin Procek
ASAgnieszka Stolarczyk
Agnieszka Stolarczyk
Tadeusz PustelnyTadeusz Pustelny
Tadeusz Pustelny
The main object of this study is the improvement of the dynamics of NO2 sensors based on ZnO nanostructures. Investigations presented in this paper showed that the combination of temperature and ultraviolet (UV) activation of the sensors can significantly decrease the sensor response and regeneration times. In comparison with the single activation method (elevated temperature or UV), these times for 1 ppm of NO2 decreased from about 10 min (or more) to less than 40 s. In addition, at the optimal conditions (200 °C and UV), sensors were very stable, were fully scalable (in the range on NO2 concentration of 1–20 ppm) and baseline drift was significantly reduced. Furthermore, in this paper, extensive studies of the influence of temperature and carrier gas (nitrogen and air) on NO2 sensing properties of the ZnO nanostructures were conducted. The NO2 sensing mechanisms of the sensors operating at elevated temperatures and under UV irradiation were also discussed. Our study showed that sensor responses to NO2 and response/regeneration times are comparable from sensor to sensor in air and nitrogen conditions, which suggests that the proposed simple technology connected with well-chosen operation conditions is repeatable. The estimated limit of detection of the sensors is within the level of ≈800 ppb in nitrogen and ≈700 ppb in air.

1 September 2009 in Acta Physica Polonica A
Verified
Journal Article
Closed access
PSPrzemyslaw Struk
Przemyslaw Struk
Tadeusz PustelnyTadeusz Pustelny
Tadeusz Pustelny
KGKazimierz Gut
Kazimierz Gut
KGK. Gołaszewska
K. Gołaszewska
EKE. Kamińska
E. Kamińska
APA. Piotrowska
A. Piotrowska