We report mode structure measurements of coherent ion cyclotron emission (ICE) and sub-cyclotron modes on DIII-D. Through a dedicated experiment, we aimed to characterize a variety of modes via the upgraded ICE diagnostic in both L- and H-mode plasmas. In the L-mode plasmas, autopower spectrum peaks at harmonics of the ion cyclotron frequency fci were observed and are localized in the core of the plasma. Sub-cyclotron modes (f ∼ 0.5fci) were also observed in L-mode plasmas when the toroidal magnetic field strength was lowered from BT = 2.17 T. In H-mode plasmas, many ICE harmonics localized to the plasma edge were observed, with some exceeding the nominal ICE diagnostic bandwidth of f ∈ [0, 100] MHz. Polarization estimates made using an orthogonal pair of vertical and horizontal magnetic pickup loops on the outer wall of the machine indicate that ICE and sub-cyclotron modes have compressional polarization at the plasma edge, the latter being consistent with simulation efforts for comparable DIII-D plasmas. For all modes, the same harmonics are observed on both the centerpost and outer wall loops, indicating that ICE is poloidally extended. Finally, toroidal mode numbers were calculated using three outer wall loops for both core ICE and sub-cyclotron modes in L-mode plasmas. The sub-cyclotron case served as a benchmark for our calculation method, with measured numbers of n ∈ [−24, −18] roughly agreeing with heuristic estimates of n ∈ [−20, −13]. Core ICE mode numbers were measured to be n ∈ [−10, 5], which is comparable to measurements made on other machines.
The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1–100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.
Novel internal measurements and analysis of ion cyclotron frequency range fast-ion driven modes in DIII-D are presented. Observations, including internal density fluctuation ( ) measurements obtained via Doppler backscattering, are presented for modes at low harmonics of the ion cyclotron frequency localized in the edge. The measurements indicate that these waves, identified as coherent ion cyclotron emission (ICE), have high wave number, k⊥ρfast ≳ 1, consistent with the cyclotron harmonic wave branch of the magnetoacoustic cyclotron instability, or electrostatic instability mechanisms. Measurements show extended spatial structure (at least ∼1/6 the minor radius). These edge ICE modes undergo amplitude modulation correlated with edge localized modes (ELM) that is qualitatively consistent with expectations for ELM-induced fast-ion transport.
More than 0.6 MW of rf power at 476 MHz has been coupled to DIII-D plasmas by launching helicon (whistler) waves with a traveling-wave antenna (comb-line) in the fast-wave polarization (Van Compernolle et al 2021 Nucl. Fusion61 116034) which resulted in the observation of electron heating of the core plasma with single-pass absorption based on ray-tracing in L-mode discharges. The coupling performance of the 1.5 m wide 30-element comb-line traveling-wave antenna has been consistent with expectations based on the 2015–2016 experiments on DIII-D with a low-power 12-element prototype (Pinsker et al 2018 Nucl. Fusion58 106007). The conditioning process that was necessary to carry out high-power experiments is discussed; rf-specific impurities have not been observed. Parametric decay instabilities have been observed and are being investigated as a potential edge absorption mechanism (Porkolab et al 2023 AIP Conf. Proc.2984 070004).
To avoid or mitigate runaway electron (RE) beams in ITER, RE-driven instabilities are actively studied as a complimentary technique to massive material injection. In this work we report experimental dependencies of Alfvénic instabilities driven by REs during the current quench in DIII-D on plasma and material injection parameters. These instabilities, observed in the frequency range of 0.1–3 MHz, correlate with increased RE loss and thus may play a role in non-sustained RE beams. It was found that as the toroidal magnetic field ( ) decreases, the RE population becomes more energetic, the energy of instabilities increases, and no RE beam is observed when the maximum energy of REs exceeds 15 MeV (or when is below 1.8 T). Analysis of disruptions at plasma core temperature ( ) of 1 keV and 8 keV shows that the RE population is much less energetic (with the maximum energy of only about 3 MeV) when is high, and no instabilities are observed in this case. Besides disruptions above caused by Ar injection, cases with Ne and D2 injections were also studied. Both Ne and D2 injections cause no sustained RE beams, however, for different reasons. Measurements of the instability polarization indicate that it is of predominantly compressional nature at the edge, which is consistent with modeling suggesting excitation of compressional Alfvén eigenmodes. However, drive of global Alfvén eigenmodes is also possible at low frequencies.
Radially resolved hydrogenic isotope fraction measurement capabilities have been developed for DIII-D using the main-ion charge exchange recombination (MICER) spectroscopy system in preparation for mixed hydrogen and deuterium experiments. Constraints on the hydrogenic ion temperatures and velocities based on measurements of the impurity ion properties are required to accurately fit the spectrum. Corrections for cross sectional distortions, spatial smearing due to the halo, and a neoclassical offset between the impurity and hydrogenic toroidal rotation are applied to the constraints prior to fitting the MICER spectrum. Extensive atomic physics calculations have been performed using the FIDASIM code, which has recently been improved to allow simulations using mixtures of hydrogenic species. These results demonstrate that for the same plasma parameters, the Dα emission is 20%–30% brighter than Hα due to differences in rate coefficients associated with the different ion thermal velocities for the same temperature and therefore must be taken into consideration when calculating absolute densities. However, despite these differences, the absolute error when estimating the hydrogen isotope fraction [nH/(nH + nD)] by using the Hα radiance fraction [LHα/(LHα + LDα)] is typically less than 5% due to the way the fraction is formed, making the radiance fraction a reasonably accurate estimate of the isotope fraction for most cases.