Akira Umeda

Akira Umeda


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AUAkira Umeda
Akira Umeda
MIMasahiro Ishizaka
Masahiro Ishizaka
IAikeda akane
ikeda akane
KMKazuya Miyagawa
Kazuya Miyagawa
AMAtsumi Mochida-Saito
Atsumi Mochida-Saito
David GozalDavid Gozal
David Gozal
In the field of respiratory clinical practice, the importance of measuring carbon dioxide (CO2) concentrations cannot be overemphasized. Within the body, assessment of the arterial partial pressure of CO2 (PaCO2) has been the gold standard for many decades. Non-invasive assessments are usually predicated on the measurement of CO2 concentrations in the air, usually using an infrared analyzer, and these data are clearly important regarding climate changes as well as regulations of air quality in buildings to ascertain adequate ventilation. Measurements of CO2 production with oxygen consumption yield important indices such as the respiratory quotient and estimates of energy expenditure, which may be used for further investigation in the various fields of metabolism, obesity, sleep disorders, and lifestyle-related issues. Measures of PaCO2 are nowadays performed using the Severinghaus electrode in arterial blood or in arterialized capillary blood, while the same electrode system has been modified to enable relatively accurate non-invasive monitoring of the transcutaneous partial pressure of CO2 (PtcCO2). PtcCO2 monitoring during sleep can be helpful for evaluating sleep apnea syndrome, particularly in children. End-tidal PCO2 is inferior to PtcCO2 as far as accuracy, but it provides breath-by-breath estimates of respiratory gas exchange, while PtcCO2 reflects temporal trends in alveolar ventilation. The frequency of monitoring end-tidal PCO2 has markedly increased in light of its multiple applications (e.g., verify endotracheal intubation, anesthesia or mechanical ventilation, exercise testing, respiratory patterning during sleep, etc.).

12 January 2006 in Respirology
Verified
Journal Article
Closed access
PDF file
AUAkira Umeda
Akira Umeda
MTManabu Tagawa
Manabu Tagawa
TKTakao Kohsaka
Takao Kohsaka
TMTomoo Miyakawa
Tomoo Miyakawa
KKKazuteru Kawasaki
Kazuteru Kawasaki
MNMiwako Nakano
Miwako Nakano

21 June 2013 in BMJ Open
Verified
Journal Article
Open access
PDF file
AUAkira Umeda
Akira Umeda
TKToru Kato
Toru Kato
TYTateki Yamane
Tateki Yamane
HYHeiichi Yano
Heiichi Yano
TITamio Ieiri
Tamio Ieiri
YOYasumasa Okada
Yasumasa Okada
Objectives A meta-analysis suggested that the use of varenicline, which is a partial agonist of nicotinic acetylcholine receptors and is effective in smoking cessation, increases the risk of cardiovascular events within 52 weeks of starting treatment. Defining these events as occurring during drug treatment (usually for 12 weeks) or within 30 days of discontinuation, another meta-analysis showed that the risk was statistically insignificant. In the present study, we aimed to clarify the effect of varenicline-assisted smoking cessation on vascular endothelial function assessed by flow-mediated vasodilation (FMD). Design Before–after and time-series. Setting Tochigi Prefecture, Japan. Participants Data of 85 participants who visited nicotine-dependent outpatient services were reviewed. FMD was repeatedly measured in 33 of the 85 participants. Inclusion criteria: 20 years and older, Brinkman index ≥200, Tobacco Dependence Screener ≥5 and stated motivation to quit smoking. Interventions Each participant was treated with varenicline titrated up to 1.0 mg twice daily (for 12 weeks in total). Primary and secondary outcome measures Participants were evaluated by FMD prior to, and 3 months after, complete smoking cessation. Follow-up FMD measurements were carried out every 3 months if possible. Changes in FMD during varenicline use were also evaluated. Results FMD was significantly increased from 4.0±1.8% to 5.5±2.2% (p<0.01, n=22) 3 months after complete cessation. Although the timecourse of FMD in most of the cases showed an increase with fluctuations, there was an exceptional case where FMD decreased over the 9 months following complete cessation. Although statistically insignificant, FMD also increased during varenicline use (from 3.7±2.7% to 4.3±2.8%, n=11). Conclusions Our observations suggest that in ceasing smokers, varenicline and smoking cessation do not lead to a worsening of the vascular endothelial function. Trial registration FK-79 (International University of Health and Welfare).

1 November 2008 in The American Journal of Emergency Medicine
Verified
Journal Article
Closed access
AUAkira Umeda
Akira Umeda
KKKazuteru Kawasaki
Kazuteru Kawasaki
TATadashi Abe
Tadashi Abe
MWMaki Watanabe
Maki Watanabe
AIAkitoshi Ishizaka
Akitoshi Ishizaka
YOYasumasa Okada
Yasumasa Okada

29 May 2020 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
AUAkira Umeda
Akira Umeda
MIMasahiro Ishizaka
Masahiro Ishizaka
MTMasamichi Tasaki
Masamichi Tasaki
TYTateki Yamane
Tateki Yamane
TWTaiji Watanabe
Taiji Watanabe
SKSarah Kesler
Sarah Kesler
Background: Usual clinical practice for arterial blood gas analysis (BGA) in conscious patients involves a one-time arterial puncture to be performed after a resting period of 20–30 min. The aim of this study was to evaluate the use of transcutaneous BGA for estimating this gold standard arterial BGA.Methods: Spontaneously breathing Asian adults (healthy volunteers and respiratory patients) were enrolled (n = 295). Transcutaneous PO2(PtcO2) and PCO2(PtcCO2) were monitored using a transcutaneous monitor (TCM4, Radiometer Medical AsP, Denmark) with sensors placed on the chest, forearm, earlobe or forehead. Transcutaneous BGA at 1-min intervals was compared with arterial BGA at 30 min. Reasonable steps to find severe hypercapnia with PaCO2 > 50 mmHg were evaluated.Results: Sensors on the chest and forearm were equally preferred and used because of small biases (n = 272). The average PCO2bias was close to 0 mmHg at 4 min, and was almost constant (4–5 mmHg) with PtcCO2being higher than PaCO2at ≥8 min. The limit of agreement for PCO2narrowed over time: ± 13.6 mmHg at 4 min, ± 7.5 mmHg at 12–13 min, and ± 6.3 mmHg at 30 min. The limit of agreement for PO2also narrowed over time (± 23.1 mmHg at 30 min). Subgroup analyses showed that the PaCO2and PaO2levels, gender, and younger age significantly affected the biases. All hypercapnia subjects with PaCO2 > 50 mmHg (n = 13) showed PtcCO2 ≥ 50 mmHg for until 12 min.Conclusions: Although PtcCO2is useful, it cannot completely replace PaCO2because PCO2occasionally showed large bias. On the other hand, the prediction of PaO2using PtcO2was unrealistic in Asian adults. PtcCO2 ≥ 50 mmHg for until 12 min can be used as a screening tool for severe hypercapnia with PaCO2 > 50 mmHg.

1 December 2004 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
AUAkira Umeda
Akira Umeda
YIYasushi Iwata
Yasushi Iwata
YOYasumasa Okada
Yasumasa Okada
MSMegumi Shimada
Megumi Shimada
ABAkiyasu Baba
Akiyasu Baba
MAMakoto Akaishi
Makoto Akaishi