Jiang Xu

Dr. Jiang Xu

School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2012 in Sensors
Verified
Journal Article
Open access
PDF file
Jiang XuJiang Xu
Jiang Xu
XWXinjun Wu
Xinjun Wu
CCCheng Cheng
Cheng Cheng
ABAnran Ben
Anran Ben
Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer for bridge cables consists of an aluminum framework, climbing modules, embedded magnetizers and a ribbon coil. The static axial magnetic field provided by the magnetizers meets the needs of the magnetic flux leakage testing and the magnetostrictive guided wave testing. The magnetizers also provide the attraction for the climbing modules. In the magnetic flux leakage testing for the free length of cable, the coil induces the axial leakage magnetic field. In the magnetostrictive guided wave testing for the anchorage zone, the coil provides a pulse high power variational magnetic field for generating guided waves; the coil induces the magnetic field variation for receiving guided waves. The experimental results show that the transducer with the corresponding inspection system could be applied to detect the broken wires in the free length and in the anchorage zone of bridge cables.

1 January 2013 in Ultrasonics
Verified
Journal Article
Closed access
Jiang XuJiang Xu
Jiang Xu
XWXinjun Wu
Xinjun Wu
PSPengfei Sun
Pengfei Sun

1 July 2022 in Materials
Verified
Journal Article
Open access
PDF file
LWLinhao Wang
Linhao Wang
Jiang XuJiang Xu
Jiang Xu
DCDong Chen
Dong Chen
Aircraft pipelines are mainly used for the storage and transportation of fuel, hydraulic oil and water, which are mostly bent pipes of non-ferromagnetic materials. We used PPM (Periodic Permanent Magnet) EMAT (Electromagnetic Acoustic Transducer) to detect the defects at 90-degree bends. A simulation model was established by finite element software to study the propagation characteristics and defect detection capability of T (0, 1) mode-guided wave in aluminum pipe bend. In terms of propagation characteristics, the energy of the guided wave was focused in the extrados of the bend, and the guided waves in the intrados and extrados of the bend were separated due to the difference in propagation distance. Regarding defect detection capability, T (0, 1) mode-guided wave had the highest detection sensitivity for the defect in the extrados of the bend and the lowest detection sensitivity for the defect in the middle area of the bend. We designed a PPM EMAT for 320 kHz to verify the simulation results experimentally, and the experimental results are in good agreement with the simulation results.

24 August 2019 in Journal of Nondestructive Evaluation
Verified
Journal Article
Closed access
PDF file
Jiang XuJiang Xu
Jiang Xu
CHChaoyue Hu
Chaoyue Hu
JDJinfeng Ding
Jinfeng Ding

31 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
XYXin Yang
Xin Yang
Jiang XuJiang Xu
Jiang Xu
SZShuchang Zhang
Shuchang Zhang
JTJun Tu
Jun Tu
Aluminum/rigid polyurethane foam composite plates (ARCPs) are widely used for thermal insulation. The interface debonding generated during manufacturing degrades the thermal insulation performance of an ARCP. In this study, the debonding of an ARCP, a composite plate with a porous and damped layer of rigid polyurethane foam (RPUF), was detected using A0 mode Lamb wave electromagnetic acoustic transducers (EMATs). The low energy transmission coefficient at the interface caused by the large acoustic impedance difference between aluminum and RPUF made the detection difficult. Based on these structural characteristics, an A0 mode Lamb wave with large out-of-plane displacement was used to detect the debonding. EMATs are preferred for generating A0 mode Lamb waves due to their advantages of being noncontact, not requiring a coupling agent, and providing convenient detection. A finite element simulation model considering the damping of the RPUF layer, the damping of the PU film at the interface, and the bonding stiffness of the interface was established. The simulation results indicated that the Lamb wave energy in the aluminum plate transmits into the RPUF layer in small amounts. However, the transmitted energy rapidly attenuated and was not reflected into the aluminum plate, as the RPUF layer was thick and highly damped. Therefore, energy attenuation was evident and could be used to characterize the debonding. An approximately linear relationship between the amplitude of the received signals and the debonding length was obtained. Experiments were performed on an ARCP using EMATs, and the experimental results were in good agreement with the simulation results.

16 January 2014 in Sensors
Verified
Journal Article
Open access
PDF file
PSPengfei Sun
Pengfei Sun
XWXinjun Wu
Xinjun Wu
Jiang XuJiang Xu
Jiang Xu
JLJian Li
Jian Li
The non-contact magnetostrictive sensor (MsS) has been widely used in the guided wave testing of pipes, cables, and so on. However, it has a disadvantage of low excitation efficiency. A new method for enhancing the excitation efficiency of the non-contact MsS for pipe inspection using guided waves, by adjusting the axial length of the excitation magnetic field, is proposed. A special transmitter structure, in which two copper rings are added beside the transmitter coil, is used to adjust the axial length at the expense of weakening the excitation magnetic field. An equivalent vibration model is presented to analyze the influence of the axial length variation. The final result is investigated by experiments. Results show that the excitation efficiency of the non-contact MsS is enhanced in the whole inspection frequency range of the L(0,2) mode if the axial length is adjusted to a certain value. Moreover that certain axial length is the same for pipes of different sizes but made of the same material.