Ljiljana Platisa

Dr. Ljiljana Platisa

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Signal Processing
Verified
Journal Article
Closed access
BCB. Cornelis
B. Cornelis
TRT. Ružić
T. Ružić
EGE. Gezels
E. Gezels
ADA. Dooms
A. Dooms
Aleksandra PižuricaAleksandra Pižurica
Aleksandra Pižurica
IDI. Daubechies
I. Daubechies

20 May 2011 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
LPLjiljana Platisa
Ljiljana Platisa
BGBart Goossens
Bart Goossens
EVEwout Vansteenkiste
Ewout Vansteenkiste
SPSubok Park
Subok Park
BGBrandon D. Gallas
Brandon D. Gallas
WPWilfried Philips
Wilfried Philips
Current clinical practice is rapidly moving in the direction of volumetric imaging. For two-dimensional (2D) images, task-based medical image quality is often assessed using numerical model observers. For three- dimensional (3D) images, however, these models have been little explored so far. In this work, first, two novel designs of a multislice channelized Hotelling observer (CHO) are proposed for the task of detecting 3D signals in 3D images. The novel designs are then compared and evaluated in a simulation study with five different CHO designs: a single-slice model, three multislice models, and a volumetric model. Four different random background statistics are considered, both Gaussian (noncorrelated and correlated Gaussian noise) and non-Gaussian (lumpy and clustered lumpy backgrounds). Overall, the results show that the volumetric model outperforms the others, while the disparity between the models decreases for greater complexity of the detection task. Among the multislice models, the second proposed CHO could most closely approach the volumetric model, whereas the first new CHO seems to be least affected by the number of training samples.

3 July 2016 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
AKAsli Kumcu
Asli Kumcu
LVLotte Vermeulen
Lotte Vermeulen
SEShirley A. Elprama
Shirley A. Elprama
PDPieter Duysburgh
Pieter Duysburgh
LPLjiljana Platisa
Ljiljana Platisa
WPWilfried Philips
Wilfried Philips

1 February 2019 in Signal Processing: Image Communication
Verified
Journal Article
Closed access
BOB. Ortiz-Jaramillo
B. Ortiz-Jaramillo
AKA. Kumcu
A. Kumcu
LPLjiljana Platisa
Ljiljana Platisa
WPW. Philips
W. Philips

12 December 2016 in IEEE Journal of Selected Topics in Signal Processing
Verified
Journal Article
Closed access
AKAsli Kumcu
Asli Kumcu
KBKlaas Bombeke
Klaas Bombeke
LPLjiljana Platisa
Ljiljana Platisa
LJLjubomir Jovanov
Ljubomir Jovanov
JLJan Van Looy
Jan Van Looy
WPWilfried Philips
Wilfried Philips
Standardization bodies recommend various protocols to conduct subjective quality assessment (QA) of imaging systems. While many studies have compared these QA protocols, few have assessed the impact of different approaches for preprocessing and analyzing quality ratings. Furthermore, the effect of large versus small quality differences on the discrimination performance of protocols has not been extensively studied in video QA. This study examines these issues for four QA protocols. H.264 compressed medical videos and denoised natural scene videos were evaluated by expert and naive subjects. Scores were collected with four QA protocols-forced choice (FC), two ratio-scaled paired comparison methods: preference (Pref) and dissimilarity (Dissim), and single stimulus (SS)-and analyzed using combinations of different rating preprocessing approaches, generating a total of 14 methods. Performance metrics-probability and effect size-quantified the ability of the methods to discriminate between quality levels. The Pref and Dissim methods analyzed with classical multidimensional scaling and the SS method with Z-score transformation consistently outperformed the other methods. The type of preprocessing introduced large differences in the performance of individual protocols. Grouping stimuli pairs by small and large quality differences introduced significant differences in the performance rankings of the methods, with Pref and Dissim being most sensitive to small quality differences. For the future, we suggest further validation of the FC method, due to its simplicity and ease of use, and continued investigation into more robust raw scores transformation and statistical analysis methods for both SS and FC ratings.

1 May 2018
Verified
Conference Paper
Closed access
LLLucie Lévêque
Lucie Lévêque
HLHantao Liu
Hantao Liu
SBSabina Baraković
Sabina Baraković
JHJasmina Baraković Husić
Jasmina Baraković Husić
MMMaria Martini
Maria Martini
ASAthanassios Skodras
Athanassios Skodras
Medical professionals are viewing an increasing number of images and videos in their clinical routine. However, various types of distortions can affect medical imaging data, and therefore impact the viewers' experienced quality and their clinical practice. Thus it is necessary to quantify this impact and understand how the viewers, i.e., medical experts, perceive the quality of (distorted) images and videos. In this paper, we present an up-to-date review of the methodologies used in the literature for the subjective quality assessment of medical images and videos and discuss their merits and drawbacks depending on the use case.