Xin Li

Dr. Xin Li


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

20 January 2020 in BMC Cancer
Verified
Journal Article
Open access
PDF file
CAChao An
Chao An
XLXin Li
Xin Li
MZMin Zhang
Min Zhang
JYJian Yang
Jian Yang
ZCZhigang Cheng
Zhigang Cheng
PLPing Liang
Ping Liang
Background: The aim of this retrospective study was to compare the feasibility and efficiency of ultrasound-guided percutaneous microwave ablation (US-PMWA) assisted by three-dimensional visualization ablation planning system (3DVAPS) and conventional 2D planning for hepatocellular carcinoma (HCC) (diameter > 3 cm). Methods: One hundred thirty patients with 223 HCC nodules (5.0 ± 1.5 cm in diameter, [3.0–10.0 cm]) who met the eligibility criteria divided into 3D and 2D planning group were reviewed from April 2015 to August 2018. Ablation parameters and oncological outcomes were compared, including overall survival (OS), recurrence-free survival (RFS), and local tumor progression (LTP). Multivariate analysis was performed on clinicopathological variables to identify the risk factors for OS and LTP. Results: The median follow-up period was 21 months (range 3–44). Insertion number (5.4 ± 1.2 VS. 4.5 ± 0.9, P = 0.034), ablation time (1249.2 ± 654.2 s VS. 1082.4 ± 584.7 s, P = 0.048), ablation energy (57,000 ± 11,892 J VS. 42,600 ± 10,271 J, P = 0.038) and success rate of first ablation (95.0% VS. 85.7%, P = 0.033) were higher in the 3D planning group compared with those in 2D planning group. There was no statistical difference in OS, and RFS between the two groups (P = 0.995, P = 0.845). LTP rate of 3D planning group was less than that of 2D planning group (16.5% VS 41.2%, P = 0.003). Multivariate analysis showed tumor maximal diameters (P < 0.001), tumor number (P = 0.003) and preoperative TACE (P < 0.001) were predictors for OS and sessions (P = 0.024), a-fetoprotein level (P = 0.004), and preoperative planning (P = 0.002) were predictors for LTP, respectively. Conclusions: 3DVAPS improves precision of US guided ablation resulting in lower LTP and higher 5 mm-AM for patients with HCC lesions larger than 3 cm in diameter.

4 July 2017 in Nanoscale
Verified
Journal Article
Closed access
PDF file
QZQunfang Zhou
Qunfang Zhou
SWSongsong Wu
Songsong Wu
NGNingqiang Gong
Ningqiang Gong
XLXin Li
Xin Li
JDJianping Dou
Jianping Dou
PLPing Liang
Ping Liang
Microwave ablation (MWA) is a promising minimally invasive therapy that has been widely used to treat hepatocellular carcinoma (HCC). However, the efficiency of MWA in treating HCC is evidently limited by the incomplete ablation of large tumors and tumors in high-risk locations. Here, we report the value of using liposomes packed with sodium chloride (NaCl-LPs) as effective thermo-seeds for MWA of HCC. The prepared liposomes exhibited excellent heat conversion ability by showing a more rapid temperature increase than free NaCl medium, blank liposomes or water under microwave irradiation. The high efficiency of this new microwave sensitization strategy was fully demonstrated in vitro in subcutaneous and orthotopic tumors. The results showed that MWA combined with NaCl-LPs clearly enhanced the ablation efficiency, leading to apparent tumor inhibition and low recurrence. What's more, we verified the susceptibility of NaCl-LPs on orthotopic tumors. Based on the unique properties of NaCl-LPs, sublethal MWA was used to mimic the transitional zone, and large-scale necrosis was observed in tumors combined with NaCl-LPs. In addition, HE staining and blood hematology analysis revealed no noticeable toxicity of NaCl-LPs in vivo, which confirmed that NaCl-LPs possessed good biocompatibility. Conclusion: The effective nanoparticles could play a valuable role in enhancing the thermo-sensitizing effect of MWA for achieving better therapeutic efficacy.

7 June 2019 in BMC Cancer
Verified
Journal Article
Open access
PDF file
XLXin Li
Xin Li
CAChao An
Chao An
FLFangyi Liu
Fangyi Liu
ZCZhigang Cheng
Zhigang Cheng
ZHZhiyu Han
Zhiyu Han
PLPing Liang
Ping Liang
To evaluate the value of a three dimension (3D)visualization operative planning system in ultrasound-guided percutaneous microwave ablation (US-PMWA) for large hepatic hemangiomas (LHHs). Fifty-eight patients with LHHs were divided into 3D and 2D groups. The therapeutic efficacy was assessed by contrast-enhanced imaging during follow-up. Hepatic and renal function were examined. The complete ablation, tumor volume shrinkage, and complication rates were analyzed. The ablation time and energy of the 3D group were lower than those of the 2D group (1152.0 ± 403.9 s vs. 1379.7 ± 375.8 s and 87,407.2.9 ± 50,387.0 J vs. 117,775.8 ± 46,245.6 J, P = 0.031 and 0.021, respectively). The 3D group had a higher complete ablation rate than the 2D group (97.7 ± 2.4% vs. 94.5 ± 3.7%, P < 0.001). The incidence of hemoglobinuria after ablation in the 3D group was lower than that in the 2D group (32.0% vs. 57.6%, P = 0.047). The levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), and creatinine (Cre) after ablation in the 3D group were lower than those in the 2D group (126.7 ± 56.4 U/L vs. 210.9 ± 96.2 U/L, P < 0.001; 141.0 ± 60.8 U/L vs. 211.4 ± 90.0 U/L, P = 0.001; 57.3 ± 17.6 U/L vs. 80.8 ± 41.9 U/L, P = 0.010; and 66.6 ± 16.6 mmol/L vs. 84.5 ± 39.6 mmol/L, P = 0.037, respectively). There were no significant differences in antenna insertion and the volume reduction rate between the groups. One patient developed acute kidney injury shortly after ablation in the 2D group and recovered after hemodialysis. No other severe complications occurred during the follow-up period. The 3D visualization operative planning system has a relatively high clinical application value in providing scientific, reasonable, quantifiable, and individualized therapy for LHHs by US-PMWA.

9 May 2019 in Experimental and Therapeutic Medicine
Verified
Journal Article
Open access
PDF file
CGChuanfen Gao
Chuanfen Gao
LWLing Wang
Ling Wang
CZChaoxue Zhang
Chaoxue Zhang
XLXin Li
Xin Li
Ultrasound guidance for histological diagnosis is in real-time, convenient, and economical. The aim of this study was to determine whether transvaginal ultrasound (TVUS)‑ and transrectal ultrasound (TRUS)-guided aspiration biopsy allows detection of a malignant pathology of pelvic/pelvic masses. Data of 40 patients with pelvic and pelvic mass lesions by computed tomography or magnetic resonance imaging underwent TVUS- or TRUS-guided biopsy. Tissue samples obtained were assessed on suitability for histopathologic evaluation. The post-biopsy complication was monitored. All the specimens in the pelvic floor, vaginal stump, vaginal fornix, cervix, and posterior wall of the anal canal were adequate for histologic diagnosis. There were no post-biopsy complications. Transvaginal/transrectal ultrasound-guided aspiration biopsy is safe and simple. It can be used for the diagnosis and differential diagnosis of pelvic and pelvic floor lesions in women. Prospective studies are needed to test diagnostic performance across clinical scenarios.