Chiara Grasso

Dr. Chiara Grasso

Unit for Research & Innovation, Department of Paediatric Anaesthesia, Istituto Giannina Gaslini, Genova, Italy
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Early Human Development
Verified
Journal Article
Closed access
CGChiara Grasso
Chiara Grasso
PSPietro Sciacca
Pietro Sciacca
VGValentina Giacchi
Valentina Giacchi
CCCaterina Carpinato
Caterina Carpinato
CMCarmine Mattia
Carmine Mattia
PBPasqua Maria Betta
Pasqua Maria Betta

2 December 2020 in Pediatric Critical Care Medicine
Verified
Journal Article
Closed access
FSFilippo Sanfilippo
Filippo Sanfilippo
VRValeria La Rosa
Valeria La Rosa
CGChiara Grasso
Chiara Grasso
CSCristina Santonocito
Cristina Santonocito
CMCarmelo Minardi
Carmelo Minardi
MAMarinella Astuto
Marinella Astuto
Objective: We conducted a systematic review and meta-analysis to investigate the prognostic value of echocardiographic parameters in pediatric septic patients. Data Sources: MEDLINE, PubMed, and EMBASE (last update April 5, 2020). Study Selection: Observational studies of pediatric sepsis providing echocardiographic parameters in relation to mortality. Data Extraction: Echocardiography data were categorized as those describing left ventricular systolic or diastolic function, right ventricular function, and strain echocardiography parameters. Data from neonates and children were considered separately. Analysis is reported as standardized mean difference and 95% CI. Data Synthesis: We included data from 14 articles (n = 5 neonates, n = 9 children). The fractional shortening was the most commonly reported variable (11 studies, n = 555 patients) and we did not identify an association with mortality (standardized mean difference 0.22, 95% CI [–0.02 to 0.47]; p = 0.07, I 2 = 28%). In addition, we did not find any association with mortality also for left ventricular ejection fraction (nine studies, n = 417; standardized mean difference 0.06, 95% CI [–0.27 to 0.40]; p = 0.72, I 2 = 51%), peak velocity of systolic mitral annular motion determined by tissue Doppler imaging wave (four studies, n = 178; standardized mean difference –0.01, 95% CI [–0.34 to 0.33]; p = 0.97, I 2 = 0%), and myocardial performance index (five studies, n = 219; standardized mean difference –0.51, 95% CI [–1.10 to 0.08]; p = 0.09, I 2 = 63%). However, in regard to left ventricular diastolic function, there was an association with mortality for higher early wave of transmitral flow/peak velocity of early diastolic mitral annular motion determined by tissue Doppler imaging ratio (four studies, n = 189, standardized mean difference –0.45, 95% CI [–0.80 to –0.10]; p = 0.01, I 2 = 0%) or lower peak velocity of early diastolic mitral annular motion determined by tissue Doppler imaging wave (three studies, n = 159; standardized mean difference 0.49, 95% CI [0.13–0.85]; p = 0.008, I 2 = 0%). We did not find any association with mortality for early wave of transmitral flow/late (atrial) wave of trans-mitral flow ratio (six studies, n = 273; standardized mean difference 0.28, 95% CI [–0.42 to 0.99]; p = 0.43, I 2 = 81%) and peak velocity of systolic mitral annular motion determined by tissue Doppler imaging wave measured at the tricuspid annulus (three studies, n = 148; standardized mean difference –0.18, 95% CI [–0.53 to 0.17]; p = 0.32, I 2 = 0%). Only a few studies were conducted with strain echocardiography. Conclusions: This meta-analysis of echocardiography parameters in pediatric sepsis failed to find any association between the measures of left ventricular systolic or right ventricular function and mortality. However, mortality was associated with higher early wave of transmitral flow/peak velocity of early diastolic mitral annular motion determined by tissue Doppler imaging or lower peak velocity of early diastolic mitral annular motion determined by tissue Doppler imaging, indicating possible importance of left ventricular diastolic dysfunction. These are preliminary findings because of high clinical heterogeneity in the studies to date.

1 June 2019 in Pediatric Critical Care Medicine
Verified
Journal Article
Closed access
AMAndrea Moscatelli
Andrea Moscatelli
FFFrancesca Febbo
Francesca Febbo
SBSilvia Buratti
Silvia Buratti
SPStefano Pezzato
Stefano Pezzato
FBFrancesca Bagnasco
Francesca Bagnasco
ECElio Castagnola
Elio Castagnola
Objectives: To describe a single institution experience on echo-guided percutaneous bicaval double lumen extracorporeal membrane oxygenation cannulation performed at the bedside by intensivists. Design: Retrospective observational study. Setting: Extracorporeal membrane oxygenation team of a tertiary care children’s hospital. Patients: All patients 0–14 years old undergoing venovenous extracorporeal membrane oxygenation from January 1, 2013, to January 1, 2018. Interventions: None. Measurements and Main Results: Thirty children underwent 32 extracorporeal membrane oxygenation runs. Median age at enrollment was 2 months (interquartile range, 0–20.5 mo), 65.6% of the runs (21 patients) were performed in newborns (n = 13, 40.6%) or infants (n = 8, 25%). Median preextracorporeal membrane oxygenation index was 66.9 (interquartile range, 50–85.6). Major comorbidities were present in 50% of patients. All patients were cannulated percutaneously. In two cases cannulation occurred from the left internal jugular vein. Extracorporeal membrane oxygenation was effective in increasing pH, arterial oxygen saturation, Pao 2, and lowering Paco 2. The overall differences in pre and postextracorporeal membrane oxygenation values were statistically significant, while stratifying patients according to the cannula diameter (mm)/major diameter of the cannulated internal jugular vein (mm) ratio (> 0.67 or ≤ 0.67), statistical significance was reached only for the highest ratio. Complications were observed in three runs: two cannula tip dislocations in the right atrium and one limited flow in the only case in which an Avalon cannula was not used. In 20 cases (62.5% of 32 runs), the cannulated vessel was patent at follow-up or autopsy. A ratio less than or equal to 0.67 or greater than 0.67 did not influence the occurrence rate of complications, nonpatency of the internal jugular vein, death for intracranial bleeding and death at 30 days from extracorporeal membrane oxygenation discontinuation. Overall cumulative survival at 30 days from extracorporeal membrane oxygenation discontinuation was 60% (95% CI, 40–75), with a survival advantage in the case of ratio greater than 0.67 (65%; 95% CI, 44–80 vs 25%; 95% CI, 0–60). Conclusions: The described technique proved to be feasible, safe, and effective. Further investigation is needed.

Verified
Journal Article
Open access
PDF file
CGChiara Grasso
Chiara Grasso
VMVanessa Marchesini
Vanessa Marchesini
NDNicola Disma
Nicola Disma
Safe management of anaesthesia in children has been one of the top areas of research over the last decade. After the large volume of articles which focused on the putative neurotoxic effect of anaesthetic agents on the developing brain, the attention and research efforts shifted toward prevention and treatment of critical events and the importance of peri-anaesthetic haemodynamic stability to prevent negative neurological outcomes. Safetots.org is an international initiative aiming at raising the attention on the relevance of a high-quality anaesthesia in children undergoing surgical and non-surgical procedures to guarantee a favourable outcome. Children might experience hemodynamic instability for many reasons, and how the range of normality within brain autoregulation is maintained is still unknown. Neuro-monitoring can guide anaesthesia providers in delivering optimal anaesthetic drugs dosages and also correcting underling conditions that can negatively affect the neurological outcome. In particular, it is referred to EEG-based monitoring and monitoring for brain oxygenation.

CGChiara Grasso
Chiara Grasso
DMDavide Massidda
Davide Massidda
KMKarolina Zaneta Maslak
Karolina Zaneta Maslak
CFCinzia Favara-Scacco
Cinzia Favara-Scacco
FGFrancesco Antonio Grasso
Francesco Antonio Grasso
OGon behalf of the MoDiPerSaPerCI Group
on behalf of the MoDiPerSaPerCI Group
Background: Although Moral Distress (MD) is a matter of concern within the Pediatric Intensive Care Unit (PICU), there is no validated Italian instrument for measuring the phenomenon in nurses and physicians who care for pediatric patients in Intensive Care. The authors of the Italian Moral Distress Scale-Revised (Italian MDS-R), validated for the adult setting, in 2017, invited further research to evaluate the generalizability of the scale to clinicians working in other fields. Our study aims to reduce this knowledge gap by developing and validating the pediatric version of the Italian MDS-R. Methods: We evaluated the new instrument for construct validity, then we administered it in a multicenter, web-based survey that involved healthcare providers of three PICUs and three adult ICUs admitting children in northern, central, and southern Italy. Finally, we tested it for internal consistency, confirmatory factorial validity, convergent validity, and differences between groups analysis. Results: The 14-item, three-factor model best fit the data. The scale showed good reliability (a = 0.87). Still, it did not correlate with the Emotional Exhaustion and Depersonalization sub-scales of the Maslach Burnout Inventory (MBI) or with the 2-item Connor-Davidson Resilience Scale (CD-RISC 2) or the Satisfaction with Life Scale (SWLS). A mild correlation was found between the Italian Pediatric MDS-R score and intention to resign from the job. No correlation was found between MD and years of experience. Females, nurses, and clinicians who cared for COVID-19 patients had a higher MD score. Conclusions: The Italian Pediatric MDS-R is a valid and reliable instrument for measuring MD among Italian health workers who care for critically ill children. Further research would be helpful in better investigating its applicability to the heterogeneous scenario of Italian Pediatric Critical Care Medicine.

1 July 2018 in The Pediatric Infectious Disease Journal
Verified
Journal Article
Closed access
PDF file
ECElio Castagnola
Elio Castagnola
LGLivia Gargiullo
Livia Gargiullo
ALAnna Loy
Anna Loy
PTPaola Tatarelli
Paola Tatarelli
ICIlaria Caviglia
Ilaria Caviglia
AMAndrea Moscatelli
Andrea Moscatelli
Infections represent a severe complication of extracorporeal membrane oxygenation (ECMO). Aim of the present study was to describe the epidemiology of infections acquired during ECMO in a tertiary care children's hospital. Retrospective analysis of clinical records of patients undergoing ECMO between January 2009 and December 2016. For each patientdata were collectedonclinical characteristics, modality of ECMO support, site and etiology of documented infections, survival within one week after ECMO weaning and/or at pediatric intensive care unit discharge. These data were employed to evaluate overall infection prevalence, infection rate (IR) expressed as episodes/1000 days of support and cumulative risk estimates of infections occurring during ECMO. During the study period a total of 46 ECMO procedures were performed. The overall prevalence of documented infections was 33%, with an IR of 27.22 and a CR of 55%. Bloodstream infection represented the most frequently documented (53%), followed by pneumonia (40%). Coagulase negative staphylococci and P.aeruginosa were prevailed as isolated pathogens. Overall survival was 59%, and 46% among those developing infections during ECMO. ECMO is a procedure at high risk for infections. Our data, limited to one center, represent a recent benchmark for further investigations.