Yulan Rao

Dr. Yulan Rao

Department of Forensic Medicine, School of Basic Medical Sciences, Fudan University, Shanghai, China

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in Journal of Chromatography B
Verified
Journal Article
Closed access
ZLZebin Lin
Zebin Lin
JLJiaolun Li
Jiaolun Li
XZXinyu Zhang
Xinyu Zhang
MQMeihong Qiu
Meihong Qiu
ZHZhibin Huang
Zhibin Huang
YRYulan Rao
Yulan Rao

7 February 2018 in Journal of Analytical Toxicology
Verified
Journal Article
Open access
PDF file
YLYuming Liu
Yuming Liu
XZXinyu Zhang
Xinyu Zhang
JLJiaolun Li
Jiaolun Li
ZHZhibin Huang
Zhibin Huang
ZLZebin Lin
Zebin Lin
YRYulan Rao
Yulan Rao
The lack of systematic studies on the stability of ethanol’s non-oxidative metabolites in postmortem specimens restricts their use in forensic cases. This study aimed to compare the stability of ethyl glucuronide (EtG), ethyl sulfate (EtS), phosphatidylethanols (PEths) and fatty acid ethyl esters (FAEEs) in postmortem human blood. Three groups were established based on the level and source of ethanol: the blank group, the ethanol-spiked group and the ethanol-positive group. Each group contained six blood samples from different corpses. The samples in each group were placed at 37, 25, 4 and −20°C. Every 24 h for 7 days, 50 μL was collected from each sample. The levels of EtG, EtS, PEths and FAEEs were determined by liquid chromatography-mass spectrometry, and their stability was evaluated. EtG was not detected in the blank group, but it was found in samples in the ethanol-spiked group placed at 37°C, and it was degraded in the ethanol-positive group at 37 and 25°C. EtS showed no change in any of the groups. PEths were not detected in the blank group, but formation was found in the ethanol-spiked group at all temperatures. In the ethanol-positive group, PEth levels fluctuated at 37°C, decreased at 25°C and increased at −20°C. FAEEs were generated in the blank group and in the ethanol-spiked group at all temperatures. In the ethanol-positive group, FAEEs were degraded at 37 and 25°C but were generated at 4 and −20°C. EtS is a reliable biomarker of ethanol consumption, and EtG could be used as a biomarker at low temperatures (4 and −20°C), but PEths and FAEEs are not appropriate biomarkers of ethanol consumption.

17 September 2020 in International journal of legal medicine
Verified
Journal Article
Closed access
PDF file
ZLZijie Lin
Zijie Lin
HWHao Wang
Hao Wang
AJAlan Wayne Jones
Alan Wayne Jones
FWFanglin Wang
Fanglin Wang
YZYunfeng Zhang
Yunfeng Zhang
YRYulan Rao
Yulan Rao

17 August 2016 in International journal of legal medicine
Verified
Journal Article
Closed access
PDF file
XWXin Wang
Xin Wang
SJSys Stybe Johansen
Sys Stybe Johansen
YZYurong Zhang
Yurong Zhang
JJJingying Jia
Jingying Jia
YRYulan Rao
Yulan Rao
KLKristian Linnet
Kristian Linnet

18 August 2015 in Journal of Forensic Sciences
Verified
Journal Article
Closed access
PDF file
HLHao Liang
Hao Liang
SKShenyi Kuang
Shenyi Kuang
LGLin Guo
Lin Guo
TYTianfang Yu
Tianfang Yu
YRYulan Rao
Yulan Rao

3 December 2014 in Forensic Toxicology
Verified
Journal Article
Closed access
PDF file
LGLin Guo
Lin Guo
ZLZebin Lin
Zebin Lin
ZHZhibin Huang
Zhibin Huang
HLHao Liang
Hao Liang
YJYan Jiang
Yan Jiang
YRYulan Rao
Yulan Rao