Virtual Shack–Hartmann wavefront sensing (vSHWS) can flexibly adjust parameters to meet different requirements without changing the system, and it is a promising means for aberration measurement. However, how to optimize its parameters to achieve the best performance is rarely discussed. In this work, the data processing procedure and methods of vSHWS were demonstrated by using a set of normal human ocular aberrations as an example. The shapes (round and square) of a virtual lenslet, the zero-padding of the sub-aperture electric field, sub-aperture number, as well as the sequences (before and after diffraction calculation), algorithms, and interval of data interpolation, were analyzed to find the optimal configuration. The effect of the above optimizations on its anti-noise performance was also studied. The Zernike coefficient errors and the root mean square of the wavefront error between the reconstructed and preset wavefronts were used for performance evaluation. The performance of the optimized vSHWS could be significantly improved compared to that of a non-optimized one, which was also verified with 20 sets of clinical human ocular aberrations. This work makes the vSHWS’s implementation clearer, and the optimization methods and the obtained results are of great significance for its applications.
11 March 2023 in Journal of Innovative Optical Health Sciences
The nonuniform distribution of interference spectrum in wavenumber k-space is a key issue to limit the imaging quality of Fourier-domain optical coherence tomography (FD-OCT). At present, the reconstruction quality at different depths among a variety of processing methods in k-space is still uncertain. Using simulated and experimental interference spectra at different depths, the effects of common six processing methods including uniform resampling (linear interpolation (LI), cubic spline interpolation (CSI), time-domain interpolation (TDI), and K-B window convolution) and nonuniform sampling direct-reconstruction (Lomb periodogram (LP) and nonuniform discrete Fourier transform (NDFT)) on the reconstruction quality of FD-OCT were quantitatively analyzed and compared in this work. The results obtained by using simulated and experimental data were coincident. From the experimental results, the averaged peak intensity, axial resolution, and signal-to-noise ratio (SNR) of NDFT at depth from 0.5 to 3.0[ ]mm were improved by about 1.9[ ]dB, 1.4 times, and 11.8[ ]dB, respectively, compared to the averaged indices of all the uniform resampling methods at all depths. Similarly, the improvements of the above three indices of LP were 2.0[ ]dB, 1.4 times, and 11.7[ ]dB, respectively. The analysis method and the results obtained in this work are helpful to select an appropriate processing method in k-space, so as to improve the imaging quality of FD-OCT.
12 August 2024 in Optics and Lasers in Engineering
A method to correct the longitudinal chromatic aberration (LCA) between the imaging beam (IB) and beacon beam of ocular adaptive optics (AO) imaging system is presented, by inserting trial spherical lens, i.e. chromatic aberration corrector (CAC), on the imaging light path. The LCA of the optical system, and the quantitative relation between the CAC diopter and the IB focus shift, are determined experimentally. Then the CAC diopter required for human eye imaging can be determined by using above results combined the existing ocular LCA data. The feasibility of this method was proved by imaging results of different samples with a model eye. Finally, the method was demonstrated to significantly improve the imaging effect in in vivo retinal AO optical coherence tomography imaging of volunteers. It does not require additional burdens, is easy-to-use and suitable for various ocular AO imaging systems.