The novel PGMY L1 consensus primer pair is more sensitive than the MY09 and MY11 primer mix for detection and typing with PCR of human papillomavirus (HPV) DNA in genital specimens. We assessed the diagnostic yield of PGMY primers for the detection and typing of HPV by comparing the results obtained with PGMY09/PGMY11 and MY09/MY11/HMB01 on 299 genital samples. Amplicons generated with PGMY primers were typed with the line blot assay (PGMY-line blot), while HPV amplicons obtained with the degenerate primer pool MY09/MY11/HMB01 were detected with type-specific radiolabeled probes in a dot blot assay (standard consensus PCR test). Cervicovaginal lavage samples ( N = 272) and cervical scrape samples ( N = 27) were tested in parallel with both PCR tests. The PGMY-line blot test detected the presence of HPV DNA more frequently than the standard consensus PCR assay. The concordance for HPV typing between the two assays was 84.3% (214 of 255 samples), for a good kappa value of 0.69. Of the 177 samples containing HPV DNA by at least one method, 40 samples contained at least one HPV type detected only with PGMY-line blot, whereas positivity exclusively with the standard consensus PCR test was found for only 7 samples ( P < 0.001). HPV types 45 and 52 were especially more frequently detected with PGMY than MY primers. However, most HPV types were better amplified with PGMY primers, including HPV-16. Samples with discordant results between the two PCR assays more frequently contained multiple HPV types. Studies using PGMY instead of MY primers have the potential to report higher detection rates of HPV infection not only for newer HPV types but also for well-known genital types.
The Roche PGMY primer-based research prototype line blot assay (PGMY-LB) is a convenient tool in epidemiological studies for the detection and typing of human papillomavirus (HPV) DNA. This assay has been optimized and is being commercialized as the Linear Array HPV genotyping test (LA-HPV). We assessed the agreement between LA-HPV and PGMY-LB for detection and typing of 37 HPV genotypes in 528 anogenital samples (236 anal, 146 physician-collected cervical, and 146 self-collected cervicovaginal swabs) obtained from human immunodeficiency virus-seropositive individuals (236 men and 146 women). HPV DNA was detected in 433 (82.0%) and 458 (86.7%) samples with PGMY-LB and LA-HPV (P= 0.047), respectively, for an excellent agreement of 93.8% (kappa = 0.76). Of the 17,094 HPV typing results, 16,562 (1,743 positive and 14,819 negative results) were concordant between tests (agreement = 96.9%; kappa = 0.76). The mean agreement between tests for each type was 96.4% ± 2.4% (95% confidence interval [CI], 95.6% to 97.2%; range, 86% to 100%), for an excellent mean kappa value of 0.85 ± 0.10 (95% CI, 0.82 to 0.87). However, detection rates for most HPV types were greater with LA-HPV. The mean number of types per sample detected by LA-HPV (4.2 ± 3.4; 95% CI, 3.9 to 4.5; median, 3.0) was greater than that for PGMY-LB (3.4 ± 3.0; 95% CI, 3.1 to 3.6; median, 2.0) (P< 0.001). The number of types detected in excess by LA-HPV in anal samples correlated with the number of types per sample (r= 0.49 ± 0.06;P= 0.001) but not with patient age (r= 0.03 ± 0.06;P= 0.57), CD4 cell counts (r= 0.06 ± 0.06;P= 0.13), or the grade of anal disease (r= −0.11 ± 0.06;P= 0.07). LA-HPV compared favorably with PGMY-LB but yielded higher detection rates for newer and well-known HPV types.
Background: HPV burden is a predictor for high-grade cervical intraepithelial neoplasia and cancer. The natural history of HPV load in young women being recently exposed to HPV is described in this paper.Methods: A total of 636 female university students were followed for 2 years. Cervical specimens with HPV-16, -18, -31, or -45 DNA by consensus PCR were further evaluated with type-specific and β-globin real-time PCR assays. Proportional hazards regression was used to estimate hazard ratios (HR) of infection clearance. Generalized estimating equations assessed whether HPV loads was predictive of HPV infection at the subsequent visit.Results: HPV loads were consistently higher among women <25 years old, and those who had multiple sex partners, multiple HPV type infections and smokers. HPV-16 integration was encountered only in one sample. Infection clearance was faster among women at lower tertiles of HPV-16 (HR = 2.8, 95%CI: 1.0-8.1), HPV-18 (HR = 3.5, 95%CI: 1.1-11.2) or combined (HR = 2.4, 95%CI: 1.8-6.2) DNA loads. The relationship between HPV-16 and HPV-18 DNA loads and infection clearance followed a clear dose-response pattern, after adjusting for age and number of sexual partners. GEE Odds Ratios for HPV persistence of the middle and upper tertiles relative to the lower tertile were 2.7 and 3.0 for HPV-16 and 3.8 and 39.1 for HPV-18, respectively. There was no association between HPV-31 or -45 DNA loads and persistence.Conclusions: The association between HPV load and persistence is not uniform across high-risk genital genotypes. HPV-16 integration was only rarely demonstrated in young women.
1 November 2007 in Journal of Clinical Microbiology
A novel real-time PCR assay for detection of human papillomavirus type 52 (HPV-52) DNA (RT-52) was evaluated on 265 anogenital samples. RT-52 had a sensitivity of 98.4% and a specificity of 100% compared to conventional HPV-52 typing assays, including hybridization of PGMY products with an HPV-52-specific probe and PCR sequencing of HPV-52 E6.