Little is known about the antimicrobial resistance (AMR) status of uropathogens in Western Africa. We performed a retrospective evaluation of urine cultures collected from the rural Margret Marquart Catholic Hospital, Kpando, Ghana during the time period from October 2019–December 2021. Urine samples from 348 patients (median age 40 years, 52.6% male) were examined. Of these, 125 (35.9%) showed either fungal or bacterial growth, including Escherichia coli in 48 (38.4%), Candida species (spp.) in 29 (23.2%), Klebsiella spp. in 27 (21.6%), Proteus spp. in 12 (9.6%), Citrobacter spp. in 10 (8.0%), Salmonella spp. in 4 (3.2%), Staphylococcus spp. in 3 (2.4%), and Pseudomonas spp. in 2 (1.6%) cases. Two bacterial spp. were detected in 7 samples (5.6%). Antibiotic susceptibility testing showed resistance to a mean 8.6 out of 11 tested antibiotics per patient. Significant predictors (p < 0.05) of bacterial growth were age (OR 1.03), female sex (OR 3.84), and the number of pus cells (OR 1.05) and epithelial cells (OR 1.07) in urine microscopy. We observed an alarmingly high AMR rate among the uropathogens detected, even to reserve antibiotics. A similar resistance profile can be expected in West African patients living in high-income countries. These observations warrant the implementation of restrictive antibiotic protocols, together with the expansion of urine culture testing capacities, improvement of documentation and reporting of AMR rates, and continued research and development of new antibiotic therapies in order to stem the progression of AMR in this West African region.
Introduction: Craniomaxillofacial fractures (CMF) are common in low-income countries (LIC). Due to limited resources, treatment of these fractures usually consists of interdental wiring or immobilization with a Barton bandage to maintain the reduction by permanent occlusion. These non-surgical treatment methods often lead to unsatisfactory results, such as a disturbed dental occlusion and lockjaw. The aim of this study is to present an off-label treatment option for CMF by applying a hand fixator as external face fixator (EFF) and to demonstrate the surgical method in detail. Materials and Methods: The feasibility and postoperative outcomes of this new off-label operation technique were evaluated by analyzing patients with CMF (n = 13) treated at an NGO hospital in Sierra Leone between 2015 and 2019. Results: The application of the EFF was feasible. The biggest advantage compared to the conventional non-operative methods was, that a dynamic occlusion was still possible during the 6 weeks healing period. Hence, patients could eat and drink almost normally and perform dental hygiene with the EFF in place. We did not discover pintrack infections or other complications. Three patients developed an oronasal fistula due to traumatic a palatal bone loss of about 7–8 mm which was treated by a palatal mucoperiosteal flap 15–20 days after the first operation. Discussion and Conclusions: In LIC, where plate osteosynthesis for CMF cannot be performed due to limited resources the application of an EFF is a promising alternative for a better outcome and an improved quality of life for the patients.
Fall-related hospitalizations among older adults have been increasing in recent decades. One of the most common reasons for this is minimal or mild traumatic brain injury (mTBI) in older individuals taking anticoagulant medication. In this study, we analyzed all inpatient stays from January 2017 to December 2019 of patients aged > 75 years with a mTBI on anticoagulant therapy who received at least two cranial computer tomography (cCT) scans. Of 1477 inpatient stays, 39 had primary cranial bleeding, and in 1438 the results of initial scans were negative for cranial bleeding. Of these 1438 cases, 6 suffered secondary bleeding from the control cCT scan. There was no significance for bleeding related to the type of anticoagulation. We conclude that geriatric patients under anticoagulant medication don’t need a second cCT scan if the primary cCT was negative for intracranial bleeding and the patient shows no clinical signs of bleeding. These patients can be dismissed but require an evaluation for need of home care or protective measures to prevent recurrent falls. The type of anticoagulant medication does not affect the risk of bleeding.
Background: The indication for minimally invasive plate osteosynthesis (MIPO) may include articular fractures depending on the fracture pattern. The goal of this study was to evaluate the feasibility of the MIPO technique for extra- and intra-articular distal humeral fractures. Methods: The feasibility of the MIPO technique was assessed on 8 cadaveric elbows and 2 clinical cases. The four surgical approaches tested included a 20-mm ulnar incision, a 20-mm dorsoradial incision, and two incisions for olecranon osteotomy (A and B). Surgical incision A was 40 mm on the osteotomy level of the olecranon, and surgical incision B was an extension of the radial incision toward the osteotomy of the olecranon (80 mm). The four approaches were tested on 4 extra-articular (AO 13 A3) fractures and 4 intra-articular (AO 13 C3) fractures. Results: Reduction and plate fixation of all distal humeral fractures (8 cadaveric) with and without osteotomy was feasible. However, when using approach B, the soft tissue tension is reduced due to the wider incision. Nevertheless, both approaches A and B showed the same adequate intra-articular fracture control and reduction. Conclusion: The MIPO technique for reduction and plate fixation in distal humeral fractures is feasible. Level of evidence: As a feasibility study, this study cannot be clearly classified into a level of evidence. It corresponds most closely to level IV.
21 August 2024 in European Journal of Trauma and Emergency Surgery
Purpose: Minimally Invasive Osteosynthesis (MIO) developed to be a key technique in orthopedic trauma surgery, offering a less invasive alternative for managing fractures in various anatomical regions. However, standardized guidelines for its application are lacking. This study aims to establish comprehensive principles for MIO to guide surgeons in treating different types of fractures and its locations. Methods: A retrospective analysis including 57 fractures in 53 patients was conducted. All patients were treated with MIO. Study range - March 2017 to January 2022 at a Level-I trauma university hospital. The analysis covered various fracture types, focusing on surgical approaches, reduction techniques, plate insertion methods, and its outcomes. The efficacy and safety of MIO was evaluated by analyzing complications, fracture healing time, and necessary revision surgeries. Results: MIO is a versatile and effective fracture treatment that minimized soft tissue damage and ensured stable osteosynthetic results. Articular fractures typically used a “one way up” plate insertion technique, while non-articular fractures applied an “inside-up-and-down” approach. Low complication rates confirmed the safety and efficiency of MIO. Conclusion: This research established generalized principles for MIO, offering a systematic approach that can be applied for various fracture types and its locations, by overall enhancing the surgical efficiency as well as patient recovery, without compromising outcomes. Level of evidence: This study is classified as Level III evidence according to “The Oxford 2011 Levels of Evidence”.
Background: The indication for minimally invasive plate osteosynthesis (MIPO) recently includes articular fractures. The goal of this study was to evaluate the feasibility of the MIPO technique for extra- and intra-articular distal humeral fractures.Methods: The feasibility of the MIPO technique was tested on 8 cadaveric elbows.The four surgical approaches tested were: a 20 mm ulnar incision, a 20 mm dorso-radial incision, and two for the olecranon osteotomy (A and B). The surgical incision A was 40 mm right on the osteotomy level of the olecranon, and B was an extension of the radial incision towards the osteotomy of the olecranon (80 mm).The four approaches were tested on 4 extra-articular (AO 13 A3) fractures and 4 intra-articular (AO 13 C3) fractures.Results: Reduction and plate fixation of all distal humeral fractures (8 cadaveric), with and without osteotomy, was feasible. But while approach A showed adequate intra-articular fracture control and reduction, approach B was too extensive to fulfill MIPO criteria. Nevertheless, both olecranon approaches were equal.Conclusion: The MIPO technique for reduction and plate fixation in distal humeral fractures is feasible.Level of Evidence: As a feasibility study, this is not clearly classified into a Level of Evidence. It corresponds most closely to level IV.