The objective of this study is to optimise the use of virtual inertia given a virtual inertia budget and a network topology. Following a brief investigation into inertia distribution, it was observed that distributed inertia is more effective than centralised inertia for a large and sparse power system network. A subsection of the South African transmission network, the Western Transmission network, is expected to host large‐scale inverter‐based generation. The total power system inertia is in decline due to the large‐scale integration of inverter‐based renewable energy generation. In the literature, mitigation methods such as virtual inertia and ‘noise‐cancelling’ network topology design has been proposed to improve frequency stability. In this study, the Western Transmission network is modelled as a network of coupled oscillators. A state‐space model for the power system network is developed with virtual inertia as a feedback control loop. The ‐norm is used to design optimal feedback control through virtual inertia allocation/distribution, to increase power system frequency stability. The results show that the optimal distribution significantly improves system frequency stability by decreasing the rate of change of frequency and delaying the time to reach similar frequency nadir values.
A method to control the output current of a three-phase grid-tied inverter is presented. An LCL-filter is used to reduce the current distortion injected into the grid. The objective is to minimise current distortion and switching frequency to reduce losses. The control approach is based on finite control set model predictive control with sphere decoding to make the problem computationally tractable for long horizons. A mathematical model was derived that extends on previous work by incorporating the effect of a grid-voltage to the system. The control strategy was evaluated through simulation. The results indicate that this control strategy can achieve the objectives for its application mentioned in the paper.
Planning for the eventual electrification of transport in sub-Saharan Africa requires accurate simulation of its unique transport systems. The few studies that attempt to model electric minibus taxis—vehicles extensively used in sub-Saharan Africa’s public transport systems—vary greatly in their results. This paper analyses, compares and corrects the only two existing studies that project energy consumption of electric minibus taxis in the region. One of the studies projected an energy consumption of 0.39 kWh/km, while the other projected 0.93 kWh/km. This paper carefully analyses the simulation tools and models and cumulatively applies corrections from the literature and scientific analyses. As a result, the discrepancy between the two simulation tools is eliminated for a given data input and a final energy consumption is estimated in the range of 0.49–0.52 kWh/km, depending on the input data.