Desheng Xu

Mr. Desheng Xu

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2025 in Energy
Verified
Journal Article
Open access
DXDesheng Xu
Desheng Xu
YLYanfeng Li
Yanfeng Li
JLJunmei Li
Junmei Li
HZhua zhong
hua zhong
JLJiaxin Li
Jiaxin Li
YHYoubo Huang
Youbo Huang

14 July 2024 in Energy
Verified
Journal Article
Open access
DXDesheng Xu
Desheng Xu
YLYanfeng Li
Yanfeng Li
JLJiaxin Li
Jiaxin Li
HZhua zhong
hua zhong
JLJunmei Li
Junmei Li
YHYoubo Huang
Youbo Huang

24 September 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
DXDesheng Xu
Desheng Xu
Yanfeng LiYanfeng Li
Yanfeng Li
JLJunmei Li
Junmei Li
ZJZhang Jin
Zhang Jin
JLJiaxin Li
Jiaxin Li
In this study, three full-scale experiments and a series of numerical simulations were conducted to investigate the influence of subway platform height and atrium ceiling height of subway stations on smoke control by mechanical exhausting systems. The smoke temperature variation with time, maximum temperature distribution, and smoke stratification were discussed. Results showed that the atrium had capacity to store smoke, especially at the early stage of smoke spread. However, the efficiency of smoke extraction did not increase simply with the rise in platform height and atrium ceiling height, and favorable smoke exhaust velocity was crucial for smoke elimination. The optimal smoke exhaust velocity was studied by numerical simulation and it was found that the area of smoke diffusion in subway stations with a higher platform was significantly smaller under the optimal smoke exhaust velocity. In addition, a prediction model of optimal smoke exhaust velocity with subway platform height was proposed. This study could provide on-site data and smoke spread characteristics for smoke control design, operation, and, significantly, guide safety evacuation of the exhaust system of subway stations.

1 May 2024 in Fire
Verified
Journal Article
Open access
PDF file
QDQiwei Dong
Qiwei Dong
Yanfeng LiYanfeng Li
Yanfeng Li
LJLi Junmei
Li Junmei
FXFei Xie
Fei Xie
DXDesheng Xu
Desheng Xu
ZSZhihe Su
Zhihe Su
In this research, the influence of confined space size on the temperature distribution characteristics of internal window plumes from well-ventilated compartment fires was studied. Theoretical analysis was firstly used to establish a mathematical model for the smoke after ejecting from the window in the space. The study considered fire heat release rate and vertical height as dependent variables. Numerical simulations and experimental methods were carried out to study the temperature variations. A critical distance L2 was obtained. Results show that when the space D between the vertical retaining wall and the building façade is greater than L2, the variation of D has little influence on radial temperature. Once D is less than L2, the radial temperature distribution inside the confined space will tend to be consistent, and the temperature in the confined space sharply increases as D decreases. In addition, a dimensionless model was derived to quantify the relationship between temperature rise and vertical height. The experimental and numerical simulation results were processed, which are in good agreement with the model. The study can provide a framework for managing building safety.

11 October 2024 in Fire
Verified
Journal Article
Open access
PDF file
DTDengkai Tu
Dengkai Tu
LJLi Junmei
Li Junmei
Yanfeng LiYanfeng Li
Yanfeng Li
DXDesheng Xu
Desheng Xu
Asymmetrical V-shaped tunnels often appear in tunnels crossing the river or urban underground road tunnels. The smoke flow inside is affected by a lot of factors. A full understanding of the smoke flow in this kind of tunnel is the basis of the smoke control. In this study, the effects of slope composition and fire heat release rate (HRR) on the longitudinal induced airflow velocity, the smoke back-layering length at the small slope side, and the maximum ceiling temperature were studied by the numerical method. The results show that when the fire occurs at the slope change point of the V-shaped tunnel, the maximum ceiling temperature decreases with the increase in the slope of the large-slope side tunnel. The longitudinally induced velocity is primarily related to the slope of the large-slope side tunnel and the fire HRR. When the slope difference between the side tunnels or the slope of the large-slope side tunnel is large, the smoke in the small-slope side tunnel flows back toward the fire source after reaching its maximum dispersion distance and then reaches a quasi-steady state. The smoke back-layering length is mainly affected by the slope and length of the large-slope side tunnel. When the slope of the large-slope side tunnel is 9%, the induced airflow velocity from the small-slope side can prevent the spread of smoke. The empirical models of the smoke back-layering length and the longitudinal induced airflow velocity in the small-slope side tunnel are drawn, respectively, by the theoretical analysis and the numerical results. This study can provide technical support for the design and operation of smoke control systems in V-shaped tunnels.

27 September 2025 in Fire Technology
Verified
Journal Article
Closed access
PDF file
DXDesheng Xu
Desheng Xu
Yanfeng LiYanfeng Li
Yanfeng Li
CCChao Chen
Chao Chen
HZhua zhong
hua zhong
JLJunmei Li
Junmei Li
YHYoubo Huang
Youbo Huang