António Manuel Mendes Raimundo

Prof. António Manuel Mendes Raimundo

University of Coimbra, ADAI, Department of Mechanical Engineering, Rua Luís Reis Santos, Pólo II, 3030-788 Coimbra, Portugal
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
Vítor CostaVítor Costa
Vítor Costa
ARAntónio Manuel Mendes Raimundo
António Manuel Mendes Raimundo

1 December 2014 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
ARAntónio Manuel Mendes Raimundo
António Manuel Mendes Raimundo
Adélio GasparAdélio Gaspar
Adélio Gaspar
AOA. Virgílio M. Oliveira
A. Virgílio M. Oliveira
DQDivo A. Quintela
Divo A. Quintela

1 May 2009 in Fire Safety Journal
Verified
Journal Article
Closed access
ARAntónio Manuel Mendes Raimundo
António Manuel Mendes Raimundo
AFAntónio R. Figueiredo
António R. Figueiredo

1 September 2020 in Building and Environment
Verified
Journal Article
Closed access
ARAntónio Manuel Mendes Raimundo
António Manuel Mendes Raimundo
Nuno Baía SaraivaNuno Baía Saraiva
Nuno Baía Saraiva
AOA. Virgilio M. Oliveira
A. Virgilio M. Oliveira

19 June 2019 in Annals of Work Exposures and Health
Verified
Journal Article
Closed access
AOA Virgílio M Oliveira
A Virgílio M Oliveira
ARAntónio Manuel Mendes Raimundo
António Manuel Mendes Raimundo
Adélio GasparAdélio Gaspar
Adélio Gaspar
DQDivo A Quintela
Divo A Quintela
This study addresses the measurement of the globe temperature. For this purpose, two globe thermometers with different diameters (50 and 150 mm) and a variety of thermal environmental conditions were considered. The assessments of the response times and of the influences of the globe diameter and the air velocity on the measured globe temperatures are discussed. The results of the response times clearly put in evidence that the values usually stated in the literature can be questioned and that longer measurement periods must be considered. In fact, response times >30 min were obtained in 68% of the tests performed. Moreover, differences >20ºC were obtained between the 150 and 50 mm sensors, highlighting the influence of the globe diameter. The analysis of the effect of the air velocity on the globe temperature shows mean relative differences >30% between tests in still air and with the higher air velocity considered (1.81 m s–1). On the basis of measurements carried out with the 50 mm globe, correction equations to the standard globe temperature for both natural and forced convection are proposed.

14 June 2013 in Journal of Building Performance Simulation
Verified
Journal Article
Closed access
SFSara C. Francisco
Sara C. Francisco
ARAntónio Manuel Mendes Raimundo
António Manuel Mendes Raimundo
Adélio GasparAdélio Gaspar
Adélio Gaspar
AOA. Virgilio M. Oliveira
A. Virgilio M. Oliveira
DQDivo A. Quintela
Divo A. Quintela
This paper presents an algorithm that calculates the radiative view factors based on Stokes’ theorem. The authors propose a formulation where the original surfaces are divided into a grid of elementary areas and Stokes’ theorem is applied for the determination of the view factors between these elementary areas. With this approach, the account of the shading effect of obstructions is significantly improved. The capabilities of the proposed formulation were tested with the calculation of radiative view factors between flat and curved surfaces. The results obtained showed a good agreement with the corresponding analytical solutions, with relative errors (REs) lower than 2%. The proposed methodology was also compared with the application of the double integral area formulation and a better agreement was found, between RE and the CPU, using the present formulation.