Francesco Pettini

Francesco Pettini


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020
Verified
Closed access
LSL. Santacroce
L. Santacroce
NSN. Sardaro
N. Sardaro
STS. Topi
S. Topi
FPFrancesco Pettini
Francesco Pettini
LBL. Bottalico
L. Bottalico
Francesco InchingoloFrancesco Inchingolo
Francesco Inchingolo

4 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAndrea Ballini
Andrea Ballini
MCMichele Di Cosola
Michele Di Cosola
RSRajiv Saini
Rajiv Saini
CBCaterina Benincasa
Caterina Benincasa
EAElisabetta Aiello
Elisabetta Aiello
SCStefania Cantore
Stefania Cantore
Background: It is well-known that toothbrushing might be associated with the development of oral soft tissue lesions. There is currently a continuing increase in the demand for new safety and performing materials in daily homecare oral hygiene including soft and extra-soft toothbrush bristles that tend to be safer. The aim of this study was to compare the efficacy of plaque control and the potential effects on gingival health of two different toothbrush bristle models. Methods: In a three-month period, a total of forty subjects were evaluated for Oral Hygiene Index (OHI), Gingival Index (GI) and Plaque Index (PI) scores as well the Gingival Abrasion Assessment (GAA) between a toothbrush entirely made from a rubber-like material called thermoplastic elastomer (TPE) and a soft toothbrush (standard control with nylon bristles) in a clinical, single-blind, controlled, parallel-group trial. Results: The use of the TPE toothbrush allows a reduction in the PI, improves the OHI and modifies the GAA in the TPE group over a period of three months compared with a conventional soft bristle toothbrush applied for the same period, leading in this way evidence for a good influence of the TPE bristles on overall oral hygiene conditions. Conclusions: From the comparison between our data and the literature studies, we can state that the material and shape of the bristles of the toothbrush affect the home practice of oral hygiene. The TPE bristles reduce the presence of plaque formation and gingival bleeding, oral soft tissue injuries acquired during homecare oral hygiene.

11 February 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
RGRoberta Grassi
Roberta Grassi
FSFábio França Vieira e Silva
Fábio França Vieira e Silva
Gennaro MusellaGennaro Musella
Gennaro Musella
FPFrancesco Pettini
Francesco Pettini
GCGISELA CRISTINA VIANNA CAMOLESI
GISELA CRISTINA VIANNA CAMOLESI
SCStefania Cantore
Stefania Cantore
Background: Immediate post-extraction dental implants are increasingly popular, but ensuring primary stability and managing peri-implant tissues remain challenging. Implant macro-design significantly impacts stability and osseointegration. This study used Cone-beam Computed Tomography (CBCT) to evaluate changes in alveolar bone following immediate placement of two implant designs, System 2P and Dura-Vit 3P, which feature semi-conical microgeometry and apical self-tapping portions for improved stability and bone regeneration. Methods: With a 1:1 allocation ratio, the current investigation was a two-arm parallel group randomized clinical trial. Patients qualified if they required immediate dental replacements with adequate buccal bone support. Two types of implants were placed: System 2P (cylindrical shape) and Dura-Vit 3P (more conical shape, with a particular architecture of threads). Following the intervention, CBCT was performed both immediately (T1) and six months later (T2). Measurements of CBCT horizontal bone level at apical, medial, and bevel height on the palatal/lingual and vestibular sides as well as the buccal vertical gap were the primary results. Complications, implant stability quotient (ISQ), and torque insertion were evaluated. The Mann–Whitney test was used to determine time-based differences within each group, while the Wilcoxon test was used to estimate differences between groups. The impact of baseline marginal gap dimension and gingival biotype was estimated using multiple regressions. Results: Thirty patients were recruited and randomized to treatments, with two lost to follow-up. One System 2P implant failed and two patients of the Dura-Vit 3P group dropped out. At T1, the Dura-Vit 3P group exhibited a lower mean insertion torque and a higher ISQ than the System 2P group. Furthermore, the Dura-Vit 3P group showed lower bone reduction compared to System 2P at horizontal and vertical measurements with significant differences for the vestibular and palatal base and medial level (p-values < 0.05). Regression models indicated a positive effect of thick biotypes on gap filling and dimensional bone reduction. No complications were observed in both groups. Conclusions: The Dura-Vit 3P implant exhibits high primary stability when inserted in post-extraction sites. Furthermore, this kind of implant stimulates higher bone stability on both the palatal and buccal side when compared to the System 2P implant. The present findings support the evidence that the macro-design of the Dura-Vit 3P implant promotes increased primary stability and reduces bone loss.

1 August 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Gennaro MusellaGennaro Musella
Gennaro Musella
SCStefania Cantore
Stefania Cantore
Maria Eleonora BizzocaMaria Eleonora Bizzoca
Maria Eleonora Bizzoca
MARIO DIOGUARDIMARIO DIOGUARDI
MARIO DIOGUARDI
RIRossella Intini
Rossella Intini
ABAndrea Ballini
Andrea Ballini
Background/Objectives: This study aimed to investigate the influence of shade and thickness on the polymerization of SDR® flow+, a low-viscosity bulk-fill composite, by assessing its degree of conversion (DC). Methods: An in vitro study was conducted using SDR® flow+ composite resin. Specimens were prepared at two thicknesses (2 mm and 4 mm) and four shades (Universal, A1, A2, A3). Polymerization was performed using a high-intensity LED curing unit. The DC was assessed using Fourier-transform infrared spectroscopy (ATR-FTIR). Results: Both shade and thickness significantly influenced DC. Thicker specimens (4 mm) exhibited reduced polymerization compared to thinner specimens (2 mm). Darker shades, particularly A3, demonstrated the lowest DC values due to their higher chroma, which limits light penetration. In contrast, the Universal shade achieved higher DC values, even at increased depths, likely due to its greater translucency. Conclusions: Shade and thickness play a critical role in the polymerization of bulk-fill composites. Ensuring adequate polymerization is essential for the longevity of pediatric restorations. Further in vivo research is needed to confirm these findings and assess their clinical implications.