Naghmeh Mahmoodian

Dr. Naghmeh Mahmoodian

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Seizure: European Journal of Epilepsy
Verified
Journal Article
Closed access
NMNaghmeh Mahmoodian
Naghmeh Mahmoodian
ABAxel Boese
Axel Boese
Michael FriebeMichael Friebe
Michael Friebe
JHJavad Haddadnia
Javad Haddadnia

15 March 2019 in Cognitive Neurodynamics
Verified
Journal Article
Closed access
PDF file
ZMZeynab Mohammadpoory
Zeynab Mohammadpoory
MNMahda Nasrolahzadeh
Mahda Nasrolahzadeh
NMNaghmeh Mahmoodian
Naghmeh Mahmoodian
MSMohammad Sayyah
Mohammad Sayyah
JHJavad Haddadnia
Javad Haddadnia

1 April 2019 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
NMNaghmeh Mahmoodian
Naghmeh Mahmoodian
ASAnna Schaufler
Anna Schaufler
APAli Pashazadeh
Ali Pashazadeh
ABAxel Boese
Axel Boese
MFMichael Friebe
Michael Friebe
AIAlfredo Illanes
Alfredo Illanes

18 December 2019 in Signal, Image and Video Processing
Verified
Journal Article
Closed access
PDF file
NMNaghmeh Mahmoodian
Naghmeh Mahmoodian
JHJavad Haddadnia
Javad Haddadnia
AIAlfredo Illanes
Alfredo Illanes
ABAxel Boese
Axel Boese
MFMichael Friebe
Michael Friebe

1 August 2022 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
NMNaghmeh Mahmoodian
Naghmeh Mahmoodian
HTHarshita Thadesar
Harshita Thadesar
MSMaryam Sadeghi
Maryam Sadeghi
MGMarilena Georgiades
Marilena Georgiades
MPMaciej Pech
Maciej Pech
CHChristoph Hoeschen
Christoph Hoeschen
Computed tomography (CT) is widely used as the imaging modality for the treatment of tumors in Microwave Ablation (MWA) therapy. In order to accurately perform ablation of liver tumors and prevent tumor recurrence it is necessary to segment both the living tumor and the ablated tissue on the CT images. The U-Net model has outperformed other methods in biomedical image segmentation. However, because of the low contrast between tumor and liver tissue texture, the traditional U-net network cannot perform an accurate segmentation of the CT images of liver during MWA therapy. The aim of this study is to improve the U-net model network to achieve a higher segmentation performance on the CT images of liver tumor inMWA therapy. To achieve this, residual block is added in the first steps of up-sampling to deepen the network depth and enhance the segmentation result. We compare the proposed method named as ‘ResLU-Net’ with a conventional U-Net model. The results show that the ResLU-Net method has a good performance in tumor segmentation with a structure similarity index (SSIM) value of 0.97. This new method can help physicians in the MWA therapy process.

22 May 2024 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
NMNaghmeh Mahmoodian
Naghmeh Mahmoodian
Mohammad RezapourianMohammad Rezapourian
Mohammad Rezapourian
AIAsim Abdulsamad Inamdar
Asim Abdulsamad Inamdar
KKKunal Kumar
Kunal Kumar
MFMelanie Fachet
Melanie Fachet
CHChristoph Hoeschen
Christoph Hoeschen
X-ray Fluorescence Computed Tomography (XFCT) is an emerging non-invasive imaging technique providing high-resolution molecular-level data. However, increased sensitivity with current benchtop X-ray sources comes at the cost of high radiation exposure. Artificial Intelligence (AI), particularly deep learning (DL), has revolutionized medical imaging by delivering high-quality images in the presence of noise. In XFCT, traditional methods rely on complex algorithms for background noise reduction, but AI holds promise in addressing high-dose concerns. We present an optimized Swin-Conv-UNet (SCUNet) model for background noise reduction in X-ray fluorescence (XRF) images at low tracer concentrations. Our method’s effectiveness is evaluated against higher-dose images, while various denoising techniques exist for X-ray and computed tomography (CT) techniques, only a few address XFCT. The DL model is trained and assessed using augmented data, focusing on background noise reduction. Image quality is measured using peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM), comparing outcomes with 100% X-ray-dose images. Results demonstrate that the proposed algorithm yields high-quality images from low-dose inputs, with maximum PSNR of 39.05 and SSIM of 0.86. The model outperforms block-matching and 3D filtering (BM3D), block-matching and 4D filtering (BM4D), non-local means (NLM), denoising convolutional neural network (DnCNN), and SCUNet in both visual inspection and quantitative analysis, particularly in high-noise scenarios. This indicates the potential of AI, specifically the SCUNet model, in significantly improving XFCT imaging by mitigating the trade-off between sensitivity and radiation exposure.